Influence of light intensity from different curing units upon composite temperature rise

被引:42
作者
Knezevic, A
Tarle, Z
Meniga, A
Sutalo, J
Pichler, G
机构
[1] Univ Zagreb, Sch Dent Med, Dept Restorat Dent, Zagreb 41000, Croatia
[2] Inst Phys, Zagreb, Croatia
关键词
blue light emitting diode; composite resins; halogen curing units; temperature rise;
D O I
10.1111/j.1365-2842.2004.01418.x
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
The unavoidable consequence of composite resin photopolymerization is temperature rise in tooth tissue. The temperature rise depends not only on the illumination time, but also on light intensity, distance of light guide tip from composite resin surface, composition and shade of composite resin and composite thickness. The most commonly used units for polymerization today are halogen curing units, which emit a large spectrum of wavelengths. A proportion of the spectrum has no influence on degree of conversion and therefore causes unnecessary temperature rise. Units based on light source - blue light emitting diodes (LED), as an alternative for halogen curing units, have been introduced in clinical practice. The aim of this study was to show the influence of the light intensity of curing units Elipar Trilight, Astralis 7 and Lux-o-Max unit on temperature rise in composite resin sample of Tetric Ceram. The temperature was measurement with Metex M-3850 D multimeter with the tip of temperature probe put into unpolymerized composite resin sample 1 mm depth. The highest temperature rise was recorded with standard curing mode for Elipar Trilight halogen curing unit (13.3 +/- 1.21 degrees C after 40 s illumination), while the lowest temperature rise was recorded for the Lux-o-Max unit based on LED technology (5.2 +/- 1.92 degrees C after 40 s illumination).
引用
收藏
页码:362 / 367
页数:6
相关论文
共 20 条
[1]
PULP CHAMBER TEMPERATURE-CHANGES WITH VISIBLE-LIGHT-CURED COMPOSITES INVITRO [J].
GOODIS, HE ;
WHITE, JM ;
GAMM, B ;
WATANABE, L .
DENTAL MATERIALS, 1990, 6 (02) :99-102
[2]
HANSEN EK, 1993, SCAND J DENT RES, V101, P176
[3]
DETERMINATION OF RADIATION ENERGY EMITTED BY LIGHT ACTIVATION UNITS [J].
HARRINGTON, E ;
WILSON, HJ .
JOURNAL OF ORAL REHABILITATION, 1995, 22 (05) :377-385
[4]
The effect of curing light intensity and test temperature on the dynamic mechanical properties of two polymer composites [J].
Harris, JS ;
Jacobsen, PH ;
O'Doherty, DM .
JOURNAL OF ORAL REHABILITATION, 1999, 26 (08) :635-639
[5]
THERMOGRAPHIC MEASUREMENT OF TEMPERATURE-CHANGE DURING RESIN COMPOSITE POLYMERIZATION IN-VIVO [J].
HUSSEY, DL ;
BIAGIONI, PA ;
LAMEY, PJ .
JOURNAL OF DENTISTRY, 1995, 23 (05) :267-271
[6]
KAUP M, 2000, DTSCH ZAHNARZTLICHE, V55, P180
[7]
Degree of conversion and temperature rise during polymerization of composite resin samples with blue diodes [J].
Knezevic, A ;
Tarle, Z ;
Meniga, A ;
Sutalo, J ;
Pichler, G ;
Ristic, M .
JOURNAL OF ORAL REHABILITATION, 2001, 28 (06) :586-591
[8]
Knezevic A, 1999, ACTA STOMATOL CROAT, V33, P337
[9]
Lieu C, 2001, J Can Dent Assoc, V67, P36
[10]
TEMPERATURE RISE DURING POLYMERIZATION OF VISIBLE LIGHT-ACTIVATED COMPOSITE RESINS [J].
MASUTANI, S ;
SETCOS, JC ;
SCHNELL, RJ ;
PHILLIPS, RW .
DENTAL MATERIALS, 1988, 4 (04) :174-178