Gadolinium-enhanced three-dimensional MR angiography of the entire aorta and iliac arteries with dynamic manual table translation

被引:47
作者
Earls, JP [1 ]
DeSena, S [1 ]
Bluemke, DA [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
关键词
aorta; MR; magnetic resonance (MR); motion correction; vascular studies;
D O I
10.1148/radiology.209.3.9844685
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
;Spoiled fast three-dimensional gradient-echo magnetic resonance imaging imaging of the aorta and iliac arteries was performed in 13 patients after administration of a single bolus of gadopentetate dimeglumine. The imaging table was moved manually 40-45 cm between two acquisitions. Arterial signal-to-noise ratio did not vary significantly between the thoracic (aortic) and pelvic stations, but venous signal-to-noise ratios increased and arterial contrast-to-noise ratios decreased on the pelvic studies. This method was feasible and increased anatomic coverage.
引用
收藏
页码:844 / 849
页数:6
相关论文
共 19 条
[1]   Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector [J].
Earls, JP ;
Rofsky, NM ;
DeCorato, DR ;
Krinsky, GA ;
Weinreb, JC .
RADIOLOGY, 1996, 201 (03) :705-710
[2]   PERIPHERAL DSA WITH AUTOMATED STEPPING [J].
FINK, U ;
HEYWANG, SH ;
HILBERTZ, T ;
FISCHER, K ;
JENNER, E ;
BUCHSTEINER, W .
EUROPEAN JOURNAL OF RADIOLOGY, 1991, 13 (01) :50-54
[3]   DIGITAL SUBTRACTION ANGIOGRAPHY OF THE EXTREMITIES USING TABLE TRANSLATION [J].
FOLEY, WD ;
MCDANIEL, D ;
MILDE, MW ;
BELL, R .
RADIOLOGY, 1985, 157 (01) :255-258
[4]   Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography [J].
Foo, TKF ;
Saranathan, M ;
Prince, MR ;
Chenevert, TL .
RADIOLOGY, 1997, 203 (01) :275-280
[5]  
HO KY, 1997, P 5 M INT SOC MAGN R, P203
[6]   Gadolinium-enhanced three-dimensional MR angiography of the thoracoabdominal aorta [J].
Krinsky, G ;
Weinreb, J .
SEMINARS IN ULTRASOUND CT AND MRI, 1996, 17 (04) :280-303
[7]   Thoracic aorta: Comparison of gadolinium-enhanced three-dimensional MR angiography with conventional MR imaging [J].
Krinsky, GA ;
Rofsky, NM ;
DeCorato, DR ;
Weinreb, JC ;
Earls, JP ;
Flyer, MA ;
Galloway, AC ;
Colvin, SB .
RADIOLOGY, 1997, 202 (01) :183-193
[8]   PERIPHERAL VASCULAR-DISEASE - EVALUATION WITH STEPPING DSA AND CONVENTIONAL SCREEN-FILM ANGIOGRAPHY [J].
MALDEN, ES ;
PICUS, D ;
VESELY, TM ;
DARCY, MD ;
HICKS, ME .
RADIOLOGY, 1994, 191 (01) :149-153
[9]  
MEANEY JF, 1997, RADIOLOGY P, V205, P462
[10]   BREATH-HOLD GADOLINIUM-ENHANCED MR-ANGIOGRAPHY OF THE ABDOMINAL-AORTA AND ITS MAJOR BRANCHES [J].
PRINCE, MR ;
NARASIMHAM, DL ;
STANLEY, JC ;
CHENEVERT, TL ;
WILLIAMS, DM ;
MARX, V ;
CHO, KJ .
RADIOLOGY, 1995, 197 (03) :785-792