Improving immunobinding using oriented immobilization of an oxidized antibody

被引:45
作者
Kang, Jung Hye [1 ]
Choi, Hyo Jin [1 ]
Hwang, Sang Youn [1 ]
Han, Sang Ho [1 ]
Jeon, Jun Yeoung [1 ]
Lee, Eun Kyu [1 ]
机构
[1] Hanyang Univ, Dept Chem Engn, Bioproc Res Lab, Ansan 426791, South Korea
关键词
magnetic particles; immunobinding; mouse IgG; oriented immobilization; ligand antibody; surface modification;
D O I
10.1016/j.chroma.2007.05.023
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Recent technical advances in biorecognition engineering and microparticle fabrication enabled us to develop a single-step purification process using magnetic particles (MPs). The process is simple, efficacious, easy to automate, and economical. The method immobilizes the ligand molecule in a particular orientation on commercial MPs that have surface carboxyl groups. Mouse IgG and anti-mouse IgG antibody were the model capture and ligand molecules for this study. The immunobinding efficacy of anti-mouse IgG antibody using "oriented immobilization" was compared with the efficacy of a conventional amine-coupling system that results in random orientation and of another standard method, the biotin-streptavidin system. The oriented immobilization was accomplished by oxidizing the sugar moiety in the CH2 domain of the antibody's Fc and covalently conjugating the moiety to the hydrazine-coated MP. The specific binding affinity of the oriented immobilization process was about 2.5 times that of the amine-coupling system, and selectivity from a binary mixture was about 2 times greater for the oriented immobilization method. Results were nearly identical for the biotin-streptavidin system and the oriented immobilization system, matching the calculated binding stoichiometry between mouse IgG and anti-mouse IgG antibody. The binding improvement over the amine-coupling system shown by assay was confirmed by a separate surface plasmon resonance experiment. In summary, the oriented immobilization method was as effective as the streptavidin-biotin system, yet simpler and cost-effective. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:9 / 14
页数:6
相关论文
共 32 条
[1]   Preparation of magnetic immobilized metal affinity separation media and its use in the isolation of proteins [J].
Abudiab, T ;
Beitle, RR .
JOURNAL OF CHROMATOGRAPHY A, 1998, 795 (02) :211-217
[2]   A rapid and sensitive magnetic bead-based immunoassay for the detection of staphylococcal enterotoxin B for high-through put screening [J].
Alefantis, T ;
Grewal, P ;
Ashton, J ;
Khan, AS ;
Valdes, JJ ;
Del Vecchio, VG .
MOLECULAR AND CELLULAR PROBES, 2004, 18 (06) :379-382
[3]   Immobilization of glucoamylase onto spacer-arm attached magnetic poly(methylmethacrylate) microspheres: characterization and application to a continuous flow reactor [J].
Arica, MY ;
Yavuz, H ;
Patir, S ;
Denizli, A .
JOURNAL OF MOLECULAR CATALYSIS B-ENZYMATIC, 2000, 11 (2-3) :127-138
[4]   USE OF AVIDIN-COATED GLASS-BEADS AS A SUPPORT FOR HIGH-PERFORMANCE IMMUNOAFFINITY CHROMATOGRAPHY [J].
BABASHAK, JV ;
PHILLIPS, TM .
JOURNAL OF CHROMATOGRAPHY, 1988, 444 :21-28
[5]   Oriented immobilization of chymotrypsin by use of suitable antibodies coupled to a nonporous solid support [J].
Bílková, Z ;
Mazurová, J ;
Churácek, J ;
Horák, D ;
Turková, J .
JOURNAL OF CHROMATOGRAPHY A, 1999, 852 (01) :141-149
[6]   THE PHYSICAL AND FUNCTIONAL-BEHAVIOR OF CAPTURE ANTIBODIES ADSORBED ON POLYSTYRENE [J].
BUTLER, JE ;
NI, L ;
NESSLER, R ;
JOSHI, KS ;
SUTER, M ;
ROSENBERG, B ;
CHANG, J ;
BROWN, WR ;
CANTARERO, LA .
JOURNAL OF IMMUNOLOGICAL METHODS, 1992, 150 (1-2) :77-90
[7]  
GHOSE TI, 1983, METHOD ENZYMOL, V93, P280
[8]   Efficient inclusion body processing using chemical extraction and high gradient magnetic fishing [J].
Heeboll-Nielsen, A ;
Choe, WS ;
Middelberg, APJ ;
Thomas, ORT .
BIOTECHNOLOGY PROGRESS, 2003, 19 (03) :887-898
[9]  
Hermanson G. T., 1996, BIOCONJUGATE TECHNIQ, P115
[10]  
Hermanson GT, 1992, IMMOBILIZED AFFINITY, P137