Solid-phase extraction coupling to capillary electrophoresis with emphasis on environmental analysis

被引:76
作者
Martínez, D [1 ]
Cugat, MJ [1 ]
Borrull, F [1 ]
Calull, M [1 ]
机构
[1] Univ Rovira & Virgili, Dept Quim Analit & Quim Organ, Tarragona 43005, Spain
关键词
reviews; solid-phase extraction; environmental analysis; preconcentration; surfactants; polynuclear aromatic hydrocarbons; dyes; amines; sulfonic acids; pesticides; phenols; aromatic acids;
D O I
10.1016/S0021-9673(00)00839-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This article reviews the status of solid-phase extraction (SPE) coupled with capillary electrophoresis (CE). It focuses on some of the organic pollutants which have captured the interest of analytical chemists - phenols, surfactants, dyes, polynuclear aromatic hydrocarbons (PAHs), aromatic and aliphatic amines, aromatic acids and aromatic sulfonic acids and, in particular, on monitoring pesticides from different sources. It shows that the coupling of SPE to CE has considerable potential in the analysis of environmental pollutants. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:65 / 89
页数:25
相关论文
共 145 条
[1]  
Aguilar C, 1996, LC GC-MAG SEP SCI, V14, P1048
[2]   Phosphated surfactants as pseudostationary phase for micellar electrokinetic chromatography: Separation of polycyclic aromatic hydrocarbons [J].
Akbay, C ;
Shamsi, SA ;
Warner, IM .
ELECTROPHORESIS, 1997, 18 (02) :253-259
[3]   Analysis of phloxine B and uranine in coffee by high-performance liquid chromatography and capillary zone electrophoresis after solid phase extraction cleanup [J].
Alcantara-Licudine, JP ;
Bui, NL ;
Kawate, MK ;
Li, QX .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1998, 46 (03) :1005-1011
[4]   TRACE ANALYSIS OF DETERGENT RESIDUES BY CAPILLARY ELECTROPHORESIS [J].
ALTRIA, KD ;
GILL, I ;
HOWELLS, JS ;
LUSCOMBE, CN ;
WILLIAMS, RZ .
CHROMATOGRAPHIA, 1995, 40 (9-10) :527-531
[5]   Direct determination of biogenic amines in wine by integrating continuous flow clean-up and capillary electrophoresis with indirect UV detection [J].
Arce, L ;
Ríos, A ;
Valcárcel, M .
JOURNAL OF CHROMATOGRAPHY A, 1998, 803 (1-2) :249-260
[6]   Flow injection-capillary electrophoresis coupling to automate on-line sample treatment for the determination of inorganic ions in waters [J].
Arce, L ;
Ríos, A ;
Valcárcel, M .
JOURNAL OF CHROMATOGRAPHY A, 1997, 791 (1-2) :279-287
[7]   AUTOMATION AND OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION [J].
ARTHUR, CL ;
KILLAM, LM ;
BUCHHOLZ, KD ;
PAWLISZYN, J ;
BERG, JR .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1960-1966
[8]   LIQUID-CHROMATOGRAPHY - PARTICLE-BEAM MASS-SPECTROMETRY FOR IDENTIFICATION OF UNKNOWN POLLUTANTS IN WATER [J].
BAGHERI, H ;
SLOBODNIK, J ;
RECASENS, RMM ;
GHIJSEN, RT ;
BRINKMAN, UAT .
CHROMATOGRAPHIA, 1993, 37 (3-4) :159-167
[9]  
Barroso MB, 1999, HRC-J HIGH RES CHROM, V22, P171, DOI [10.1002/(SICI)1521-4168(19990301)22:3<171::AID-JHRC171>3.0.CO
[10]  
2-Z, 10.1002/(SICI)1521-4168(19990301)22:3&lt