Tensile fixation strengths of absorbable meniscal repair devices as a function of hydrolysis time - An in vitro experimental study

被引:59
作者
Arnoczky, SP [1 ]
Lavagnino, M [1 ]
机构
[1] Michigan State Univ, Coll Vet Med, Lab Comparat Orthopaed Res, E Lansing, MI 48824 USA
关键词
D O I
10.1177/03635465010290020201
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To determine the effect of hydrolysis time on the fixation strength of absorbable meniscal repair devices, adult bovine menisci were repaired with five devices and a suture. The ultimate tensile strength of the repair was then tested in six specimens immediately or after 6, 12, or 24 weeks of incubation at 37 degreesC in a saline solution containing antibiotics, antimycotics, and protease inhibitors. Immediately after implantation the Bionx Meniscus Arrow had a significantly higher failure strength (57.7 +/- 13.8 N) than the Linvatec BioStinger (35.1 +/- 6.7 N), the Innovasive Clearfix screw (34.9 +/- 13 N), the Surgical Dynamics S.D.sorb staple (9.4 +/- 4.6 N), and the Mitek Meniscal Repair System (polydioxanone) (27.2 +/- 6.0 N). However, there was no significant difference between the Bionx Meniscus Arrow and a 2-0 polydioxanone vertical suture (51.6 +/- 2.7 N). The polydioxanone-based implants demonstrated a significant decrease in failure strength at 12 and 24 weeks. Similarly, the Surgical Dynamics S.D.sorb staple lost all fixation strength by 24 weeks. The remaining devices showed no significant loss of failure strength over the 24-week period, suggesting that 24 weeks of hydrolysis does not adversely affect the ultimate holding power of poly L-lactide-based meniscal fixation devices.
引用
收藏
页码:118 / 123
页数:6
相关论文
共 21 条
[1]
Failure strength of a new meniscus arrow repair technique: Biomechanical comparison with horizontal suture [J].
AlbrechtOlsen, P ;
Lind, T ;
Kristensen, G ;
Falkenberg, B .
ARTHROSCOPY, 1997, 13 (02) :183-187
[2]
WINNER OF THE 1982 ODONOGHUE AWARD - THE MICROVASCULATURE OF THE MENISCUS AND ITS RESPONSE TO INJURY - AN EXPERIMENTAL-STUDY IN THE DOG [J].
ARNOCZKY, SP ;
WARREN, RF .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1983, 11 (03) :131-141
[3]
BARBER F A, 1988, Arthroscopy, V4, P272, DOI 10.1016/S0749-8063(88)80043-4
[4]
ACCELERATED REHABILITATION FOR MENISCUS REPAIRS [J].
BARBER, FA .
ARTHROSCOPY, 1994, 10 (02) :206-210
[5]
THE EFFECT OF INFLAMMATORY SYNOVIAL-FLUID ON THE BREAKING STRENGTH OF NEW LONG LASTING ABSORBABLE SUTURES [J].
BARBER, FA ;
CLICK, JN .
ARTHROSCOPY, 1992, 8 (04) :437-441
[6]
Meniscus repair rehabilitation with concurrent anterior cruciate reconstruction [J].
Barber, FA ;
Click, SD .
ARTHROSCOPY, 1997, 13 (04) :433-437
[7]
BARBER FA, 1988, AM J KNEE SURG, V1, P189
[8]
Pull-out strength and stiffness of meniscal repair using absorbable arrows or Ti-Cron vertical and horizontal loop sutures [J].
Boenisch, UW ;
Faber, KJ ;
Ciarelli, M ;
Steadman, JR ;
Arnoczky, SP .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1999, 27 (05) :626-631
[9]
Broken arrow: A complication of meniscal repair [J].
Calder, SJ ;
Myers, PT .
ARTHROSCOPY, 1999, 15 (06) :651-652
[10]
CANNON WD, 1999, ARTHROSCOPIC MENISCA