Optimization of Phosphatase- and Redox Cycling-Based Immunosensors and Its Application to Ultrasensitive Detection of Troponin I

被引:103
作者
Akanda, Md. Rajibul [1 ,2 ]
Aziz, Md. Abdul [1 ,2 ]
Jo, Kyungmin [1 ,2 ]
Tamilavan, Vellaiappillai [1 ,2 ]
Hyun, Myung Ho [1 ,2 ]
Kim, Sinyoung [3 ]
Yang, Haesik [1 ,2 ]
机构
[1] Pusan Natl Univ, Dept Chem, Pusan 609735, South Korea
[2] Pusan Natl Univ, Chem Inst Funct Mat, Pusan 609735, South Korea
[3] Yonsei Univ, Dept Lab Med, Coll Med, Seoul 135720, South Korea
关键词
ASCORBIC-ACID; 2-PHOSPHATE; ALKALINE-PHOSPHATASE; ELECTROCHEMICAL IMMUNOSENSOR; IMMUNOASSAY; ASSAY; SUBSTRATE; PROTEIN; PERFORMANCE; ELECTRODES; DISEASE;
D O I
10.1021/ac200447b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The authors herein report optimized conditions for ultrasensitive phosphatase-based immunosensors (using redox cycling by a reducing agent) that can be simply prepared and readily applied to microfabricated electrodes. The optimized conditions were applied to the ultrasensitive detection of cardiac troponin I in human serum. The preparation of an immunosensing layer was based on passive adsorption of avidin (in carbonate buffer (pH 9.6)) onto indium tin oxide (ITO) electrodes. The irnmunosensing layer allows very low levels of nonspecific binding of proteins. The optimum conditions for the enzymatic reaction were investigated in terms of the type of buffer solution, temperature, and concentration of MgCl(2), and the optimum conditions for antigen antibody binding were determined in terms of incubation time, temperature, and concentration of phosphatase-conjugated IgG. Very importantly, the antigen antibody binding at 4 degrees C is extremely important in obtaining reproducible results. Among the four phosphatase substrates (L-ascorbic acid 2-phosphate (AAP), 4-aminophenyl phosphate, 1-naphthyl phosphate, 4-amino-1-naphthyl phosphate) and four phosphatase products (L-ascorbic acid (AA), 4-aminophenol, 1-naphthol, 4-amino-1-naphthol), AAP and AA meet the requirements most for obtaining easy dissolution and high signal-to-background ratios. More importantly, fast AA electrooxidation at the ITO electrodes does not require modification with any electrocatalyst or electron mediator. Furthermore, tris(2-carboxyethyl)phosphine (TCEP) as a reducing agent allows fast redox cycling, along with very low anodic currents at the ITO electrodes. Under these optimized conditions, the detection limit of an immunosensor for troponin I obtained without redox cycling of AA by TCEP is ca. 100 fg/mL, and with redox cycling it is ca. 10 fg/mL. A detection limit of 10 fg/mL was also obtained even when an immunosensing layer was simply formed on a micropatterned ITO electrode. From a practical point of view, it is of great importance that ultralow detection limits can be obtained with simply prepared enzyme-based immunosensors.
引用
收藏
页码:3926 / 3933
页数:8
相关论文
共 31 条
[1]   A facile method of achieving low surface coverage of Au nanoparticles on an indium tin oxide electrode and its application to protein detection [J].
Aziz, Md. Abdul ;
Patra, Srikanta ;
Yang, Haesik .
CHEMICAL COMMUNICATIONS, 2008, (38) :4607-4609
[2]   Zeptomole-detecting biosensor for alkaline phosphatase in an electrochemical immunoassay for 2,4-dichlorophenoxyacetic acid [J].
Bauer, CG ;
Eremenko, AV ;
EhrentreichForster, E ;
Bier, FF ;
Makower, A ;
Halsall, HB ;
Heineman, WR ;
Scheller, FW .
ANALYTICAL CHEMISTRY, 1996, 68 (15) :2453-2458
[3]  
BODOR GS, 1992, CLIN CHEM, V38, P2203
[4]   The oxidative mechanism of action of ortho-quinone inhibitors of protein-tyrosine phosphatase α is mediated by hydrogen peroxide [J].
Bova, MP ;
Mattson, MN ;
Vasile, S ;
Tam, D ;
Holsinger, L ;
Bremer, M ;
Hui, T ;
McMahon, G ;
Rice, A ;
Fukuto, JM .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 2004, 429 (01) :30-41
[5]   Electrochemical immunosensor using p-aminophenol redox cycling by hydrazine combined with a low background current [J].
Das, Jagotamoy ;
Jo, Kyungmin ;
Lee, Jae Wook ;
Yang, Haesik .
ANALYTICAL CHEMISTRY, 2007, 79 (07) :2790-2796
[6]   Screen-printed microfluidic device for electrochemical immunoassay [J].
Dong, Hua ;
Li, Chang-Ming ;
Zhang, Yi-Fan ;
Cao, Xiao-Dong ;
Gan, Ye .
LAB ON A CHIP, 2007, 7 (12) :1752-1758
[7]   Automated detection and quantitation of bacterial RNA by using electrical microarrays [J].
Elsholz, B. ;
Woerl, R. ;
Blohm, L. ;
Albers, J. ;
Feucht, H. ;
Grunwald, T. ;
Juergen, B. ;
Schweder, T. ;
Hintsche, Rainer .
ANALYTICAL CHEMISTRY, 2006, 78 (14) :4794-4802
[8]   CONTROL OF THE SPECIFIC ADSORPTION OF PROTEINS ONTO GOLD SURFACES WITH POLY(L-LYSINE) MONOLAYERS [J].
FREY, BL ;
JORDAN, CE ;
KORNGUTH, S ;
CORN, RM .
ANALYTICAL CHEMISTRY, 1995, 67 (24) :4452-4457
[9]   Cardiac markers: a clear cause for point-of-care testing [J].
Friess, Ulrich ;
Stark, Maik .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (05) :1453-1462
[10]   A new chemically amplified electrochemical system for the detection of biological affinity reactions: direct and competitive biotin assay [J].
Guo, LH ;
Yang, XQ .
ANALYST, 2005, 130 (07) :1027-1031