In vivo survival of apheresis RBCs, frozen with 40-percent (wt/vol) glycerol, deglycerolized in the ACP 215, and stored at 4°C in AS-3 for up to 21 days

被引:38
作者
Valeri, CR
Ragno, G
Pivacek, L
O'Neill, EM
机构
[1] Boston Univ, Sch Med, USN, Blood Res Lab, Boston, MA 02118 USA
[2] Amer Res Cross Blood Serv, Dedham, MA USA
关键词
D O I
10.1046/j.1537-2995.2001.41070928.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: The FDA has approved the storage of frozen RBCs at -80 degreesC for 10 years and the postwash storage at 4 degreesC for no more than 24 hours. The 4 degreesC postwash storage period is limited to 24 hours, because the current deglycerolization systems are functionally open systems. STUDY DESIGN AND METHODS: Two units of RBCs were collected from each of 13 healthy male volunteers. The RBCs were collected in CP2D by the FDA-approved protocol for an automated apheresis device (MCS, LN8150, Haemonetics) and were stored at 4 degreesC in AS-3 for 6 days. Using a single disposable glycerolization set in an automated, functionally closed system (ACP 215, Haemonetics) each unit was transferred to a 1000-mL PVC plastic bag and glycerolized to a concentration of 40-percent (wt/vol) glycerol and frozen at -80 degreesC. A single disposable deglycerolization set in the ACP 215 was used to deglycerolize the 2 units from the same donor. The deglycerolized RBCs were stored at 4 degreesC in AS-3 for as long as 21 days. RESULTS: The mean +/- SD freeze-thaw-wash recovery value was 89.4 +/- 3 percent. The residual hemolysis in the RBCs stored at 4 degreesC in AS-3 for 21 days after deglycerolization was 0.9 +/- 0.2 percent, and the units were negative for both aerobic and anaerobic bacteria. The mean Nageotte WBC count was 9 x 10(6) per unit. When the deglycerolized RBCs were given as an autologous transfusion after storage at 4 degreesC in AS-3 for the 7- to 18-day period, the mean +/- SD 24-hour posttransfusion survival was 77 +/- 7 percent, and the index of therapeutic effectiveness was 69 +/- 8 percent. CONCLUSION: Two units of human RBCs collected from a single donor by apheresis in the MCS using an LN8150 set can be glycerolized sequentially with a single disposable set and deglycerolized sequentially with another single disposable set in the ACP 215. The previously frozen RBCs stored in AS-3 for 7 to 18 days at 4 degreesC had acceptable hemolysis and an acceptable mean 24-hour posttransfusion survival value and index of therapeutic effectiveness.
引用
收藏
页码:928 / 932
页数:5
相关论文
共 20 条
[1]   SPECTROPHOTOMETRIC SCANNING TECHNIQUE FOR RAPID-DETERMINATION OF PLASMA HEMOGLOBIN [J].
BLAKNEY, GB ;
DINWOODIE, AJ .
CLINICAL BIOCHEMISTRY, 1975, 8 (02) :96-102
[2]   PURIFICATION OF RED-CELLS FOR TRANSFUSION BY FREEZE PRESERVATION AND WASHING .2. RESIDUAL LEUKOCYTES, PLATELETS, AND PLASMA IN WASHED, FREEZE-PRESERVED RED-CELLS [J].
CROWLEY, JP ;
VALERI, CR .
TRANSFUSION, 1974, 14 (03) :196-202
[3]   PURIFICATION OF RED-CELLS FOR TRANSFUSION BY FREEZE-PRESERVATION AND WASHING .3. LEUKOCYTE REMOVAL AND RED-CELL RECOVERY AFTER RED-CELL FREEZE-PRESERVATION BY HIGH OR LOW GLYCEROL CONCENTRATION METHOD [J].
CROWLEY, JP ;
VALERI, CR .
TRANSFUSION, 1974, 14 (06) :590-594
[4]   IMMUNOCOMPETENT LYMPHOCYTES IN PREVIOUSLY FROZEN WASHED RED-CELLS [J].
CROWLEY, JP ;
SKRABUT, EM ;
VALERI, CR .
VOX SANGUINIS, 1974, 26 (06) :513-517
[5]   A METHOD FOR COUNTING LEUKOCYTES IN FILTERED COMPONENTS [J].
GREENWALT, TJ ;
ALLEN, CM .
TRANSFUSION, 1990, 30 (04) :377-379
[6]   Complement activation during storage of whole blood, red cells, plasma, and buffy coat [J].
Hyllner, M ;
Arnestad, JP ;
Bengtson, JP ;
Rydberg, L ;
Bengtsson, A .
TRANSFUSION, 1997, 37 (03) :264-268
[7]   IMMUNOCOMPETENCE OF RESIDUAL LYMPHOCYTES AT VARIOUS STAGES OF RED-CELL CRYOPRESERVATION WITH 40-PERCENT W-V GLYCEROL IN AN IONIC MEDIUM AT -80C [J].
KURTZ, SR ;
VANDEINSE, WH ;
VALERI, CR .
TRANSFUSION, 1978, 18 (04) :441-447
[8]   LEUKOCYTE-POOR RED-BLOOD-CELLS PREPARED BY THE ADDITION AND REMOVAL OF GLYCEROL FROM RED-BLOOD-CELL CONCENTRATES STORED AT 4-DEGREES-C [J].
KURTZ, SR ;
VALERI, DA ;
MELARAGNO, AJ ;
GRAY, A ;
VECCHIONE, JJ ;
EMERSON, CP ;
VALERI, CR .
TRANSFUSION, 1981, 21 (04) :435-442
[9]   LARGE-VOLUME HEMOCYTOMETER CHAMBER FOR ACCURATE COUNTING OF WHITE CELLS (WBCS) IN WBC-REDUCED PLATELETS - VALIDATION AND APPLICATION FOR QUALITY-CONTROL OF WBC-REDUCED PLATELETS PREPARED BY APHERESIS AND FILTRATION [J].
LUTZ, P ;
DZIK, WH .
TRANSFUSION, 1993, 33 (05) :409-412
[10]   Time-dependent histamine release from stored human blood products [J].
Nielsen, HJ ;
Edvardsen, L ;
Vangsgaard, K ;
Dybkjaer, E ;
Skov, PS .
BRITISH JOURNAL OF SURGERY, 1996, 83 (02) :259-262