Evaluation of gadopentetate dimeglumine magnetic resonance cisternography in an animal model - Preliminary report

被引:34
作者
Jinkins, JR
Williams, RF
Xiong, L
机构
[1] Univ Texas, Hlth Sci Ctr, Dept Radiol, Neuroradiol Sect, San Antonio, TX 78284 USA
[2] Univ Texas, Hlth Sci Ctr, Dept Biochem, San Antonio, TX 78284 USA
关键词
MR; MR myelography/cisternography; intrathecal gadopentetate dimeglumine injection; rabbit;
D O I
10.1097/00004424-199902000-00009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. TO evaluate magnetic resonance (MR) imaging characteristics of the cisternal administration of gadopentetate dimeglumine (gadolinium) in a small experimental animal. METHODS. Four female New Zealand White rabbits were used for this experiment. Each rabbit received a single dose of intrathecal gadolinium (doses ranged from 75-100 umol) via a cisternal puncture, Immediate and delayed sagittal and axial T1-weighted images of the brain and cervical spinal cord were acquired on a 2 Tesla CSI magnet. RESULTS. All the rabbits tolerated the experiment well, without significant alterations in behavior or seizure activity. During the early phase of imaging, subarachnoid space enhancement was observed over the surface of the brain parenchyma and spinal cord on T1-weighted images. Gradual diffusion of the gadolinium into the cranial parenchyma was seen on the delayed MR studies (45 minutes-6 hours), as revealed by progressive generalized enhancement of the brain. Sustained enhancement of gray matter of the spinal cord was observed. CONCLUSION. This study illustrates that there is no barrier between the cerebrospinal fluid (CSF) and the brain-spinal cord with regard to gadolinium, Possible practical applications for gadolinium-enhanced MR myelography or cisternography include the assessment of communication or obstruction of CSF pathways, subarachnoid space CSF flow pattern analysis, spontaneous or acquired CSF fistula evaluation, evaluation of the intercommunication of central nervous system cystic structures bordering on CSF pathways, and the study of the dynamics of gadolinium diffusion in the central nervous system parenchyma.
引用
收藏
页码:156 / 159
页数:4
相关论文
共 18 条
[1]  
ALLARD M, 1987, J NEURORADIOLOGY, V14, P383
[2]  
DAVSON H, 1976, J PHYSIOL-LONDON, V255, P1
[3]   MR CISTERNOGRAPHY AND MYELOGRAPHY WITH GD-DTPA IN MONKEYS [J].
DICHIRO, G ;
KNOP, RH ;
GIRTON, ME ;
DWYER, AJ ;
DOPPMAN, JL ;
PATRONAS, NJ ;
GANSOW, OA ;
BRECHBIEL, MW ;
BROOKS, RA .
RADIOLOGY, 1985, 157 (02) :373-377
[4]  
DRAYER B P, 1977, Acta Radiologica Supplementum, P280
[5]   SAFETY ASSESSMENT OF GADOPENTETATE DIMEGLUMINE IN UNITED-STATES CLINICAL-TRIALS [J].
GOLDSTEIN, HA ;
KASHANIAN, FK ;
BLUMETTI, RF ;
HOLYOAK, WL ;
HUGO, FP ;
BLUMENFIELD, DM .
RADIOLOGY, 1990, 174 (01) :17-23
[6]   MODIFICATION OF PERIVENTRICULAR HYPODENSITY IN HYDROCEPHALUS WITH VENTRICULAR REFLUX IN METRIZAMIDE CT CISTERNOGRAPHY [J].
HIRATSUKA, H ;
FUJIWARA, K ;
OKADA, K ;
TAKASATO, Y ;
TSUYUMU, M ;
INABA, Y .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (02) :204-208
[7]   SAFETY OF GADOLINIUM-DTPA - EXTENDED CLINICAL-EXPERIENCE [J].
NIENDORF, HP ;
HAUSTEIN, J ;
CORNELIUS, I ;
ALHASSAN, A ;
CLAUSS, W .
MAGNETIC RESONANCE IN MEDICINE, 1991, 22 (02) :222-228
[8]   SAFETY AND TOLERANCE AFTER INTRAVENOUS ADMINISTRATION OF 0.3 MMOL KG GD-DTPA - RESULTS OF A RANDOMIZED, CONTROLLED CLINICAL-TRIAL [J].
NIENDORF, HP ;
HAUSTEIN, J ;
LOUTON, T ;
BECK, W ;
LANIADO, M .
INVESTIGATIVE RADIOLOGY, 1991, 26 :S221-S223
[9]   BRAIN EXTRACELLULAR SPACE AND SINK ACTION OF CEREBROSPINAL FLUID - MEASUREMENT OF RABBIT BRAIN EXTRACELLULAR SPACE USING SUCROSE LABELED WITH CARBON 14 [J].
OLDENDORF, WH ;
DAVSON, H .
ARCHIVES OF NEUROLOGY, 1967, 17 (02) :196-+
[10]  
RALL DAVID P., 1962, LIFE SCI, V2, P43