Hardware and software for tachistoscopy: How to make accurate measurements on any PC utilizing the Microsoft Windows operating system

被引:18
作者
McKinney, CJ [1 ]
MacCormac, ER [1 ]
Welsh-Bohmer, KA [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
来源
BEHAVIOR RESEARCH METHODS INSTRUMENTS & COMPUTERS | 1999年 / 31卷 / 01期
关键词
D O I
10.3758/BF03207703
中图分类号
B841 [心理学研究方法];
学科分类号
040201 ;
摘要
Methods for automated stimulus display and accurate response time measurement with IBM-compatible PCs are of great importance in cognitive research designs. Accurate measurements of re action times are required to interpolate other measures, such as speed of mental processing. We present a description of hardware and software that displays stimulus images and performs reaction timing that is not dependent on PC performance characteristics. This is accomplished by electronically bypassing timing errors normally inherent to the operation of the computer. A high-precision external timer measures the time between stimulus onset and a subject's push-button response while a video blanking circuit controls the video presented to the monitor screen. Two options for accurately detecting stimulus onset are presented: (1) A photodetector can be used to sense the actual onset of the stimulus on a secondary video monitor screen; (2) the video blanking circuit can provide a signal coincident with the initiation of video to the monitor. Both methods result in a system timing accuracy of 100 mu sec.
引用
收藏
页码:129 / 136
页数:8
相关论文
共 11 条
[1]   MICROMANAGING TIME - MEASURING AND CONTROLLING TIMING ERRORS IN COMPUTER-CONTROLLED EXPERIMENTS [J].
CREEGER, CP ;
MILLER, KF ;
PAREDES, DR .
BEHAVIOR RESEARCH METHODS INSTRUMENTS & COMPUTERS, 1990, 22 (01) :34-79
[2]   EXPERIMENTAL RUNTIME SYSTEM - SOFTWARE FOR DEVELOPING AND RUNNING REACTION-TIME EXPERIMENTS ON IBM-COMPATIBLE PCS [J].
DUTTA, A .
BEHAVIOR RESEARCH METHODS INSTRUMENTS & COMPUTERS, 1995, 27 (04) :516-519
[3]   HOW TO OBTAIN NEAR-MILLISECOND PRECISION ON THE IBM PC WITH VISUAL-STIMULI NOT EXCEEDING ONE PRINTED LINE [J].
GABRIELSSON, J ;
JARVELLA, RJ .
BEHAVIOR RESEARCH METHODS INSTRUMENTS & COMPUTERS, 1990, 22 (06) :520-525
[4]   MILLISECOND TIMING ON THE IBM PC/XT/AT AND PS/2 - A REVIEW OF THE OPTIONS AND CORRECTIONS FOR THE GRAVES AND BRADLEY ALGORITHM [J].
GRAVES, RE ;
BRADLEY, R .
BEHAVIOR RESEARCH METHODS INSTRUMENTS & COMPUTERS, 1991, 23 (03) :377-379
[5]  
KEMP P, 1996, ELECT DESIGN NE 0509, P89
[6]   TACHISTOSCOPIC APPLICATIONS OF MICRO EXPERIMENTAL LABORATORY (MEL) USED WITH IBM PC COMPATIBLES - STIMULUS AND RESPONSE TIMING ISSUES [J].
MOGG, K ;
BRADLEY, BP .
BEHAVIOR RESEARCH METHODS INSTRUMENTS & COMPUTERS, 1995, 27 (04) :512-515
[7]   AN INEXPENSIVE 1-MILLISECOND EXPERIMENT CONTROL INTERFACE FOR IBM PCS AND ITS USER-FRIENDLY CONTROL LANGUAGE [J].
PALYA, WL ;
WALTER, DE ;
CHU, JYM .
BEHAVIOR RESEARCH METHODS INSTRUMENTS & COMPUTERS, 1995, 27 (02) :129-130
[8]   GRAPHIC PRECISION - CONTROLLING STIMULUS DISPLAYS ON IBM-PC-COMPATIBLE COMPUTERS [J].
PAREDES, DR ;
MILLER, KF ;
CREEGER, C .
BEHAVIOR RESEARCH METHODS INSTRUMENTS & COMPUTERS, 1990, 22 (03) :319-322
[9]  
RODGERS KA, 1995, MEL PROFESSIONAL LAN, V1
[10]   SUITABILITY OF THE IBM-XT, AT, AND PS/2 KEYBOARD, MOUSE, AND GAME PORT AS RESPONSE DEVICES IN REACTION-TIME PARADIGMS [J].
SEGALOWITZ, SJ ;
GRAVES, RE .
BEHAVIOR RESEARCH METHODS INSTRUMENTS & COMPUTERS, 1990, 22 (03) :283-289