Estimation of pore diameter for intraparticle fluid flow in bidisperse porous chromatographic particles

被引:13
作者
Heeter, GA
Liapis, AI
机构
[1] UNIV MISSOURI,DEPT CHEM ENGN,ROLLA,MO 65401
[2] UNIV MISSOURI,BIOCHEM PROC INST,ROLLA,MO 65401
关键词
mathematical models; adsorbents; porous adsorbent particles; intraparticle fluid flow; perfusion chromatography; pore size; proteins;
D O I
10.1016/S0021-9673(96)00791-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A quantitative method is developed and presented for estimating the mean pore diameter, d(pore), that could allow intraparticle fluid flow in the macroporous region of adsorbent particles with a bidisperse porous structure packed in a column. The method is used to estimate the value of d(pore) that is required to obtain specified values of the fraction, F, of the column superficial fluid velocity that is flowing through the macroporous region of the adsorbent particles and the value of d(pore) that is required to obtain specified values of the intraparticle Peclet number, Pe(intra).
引用
收藏
页码:35 / 40
页数:6
相关论文
共 25 条
[1]   FLOW-THROUGH PARTICLES FOR THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF BIOMOLECULES - PERFUSION CHROMATOGRAPHY [J].
AFEYAN, NB ;
GORDON, NF ;
MAZSAROFF, I ;
VARADY, L ;
FULTON, SP ;
YANG, YB ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY, 1990, 519 (01) :1-29
[2]  
Bird R.B., 2006, TRANSPORT PHENOMENA, Vsecond, DOI 10.1002/aic.690070245
[3]   DIFFUSION AND CONVECTION IN CHROMATOGRAPHIC PROCESSES USING PERMEABLE SUPPORTS WITH A BIDISPERSE PORE STRUCTURE [J].
CARTA, G ;
RODRIGUES, AE .
CHEMICAL ENGINEERING SCIENCE, 1993, 48 (23) :3927-3935
[4]  
CARTA G, 1992, SEPAR TECHNOL, V2, P62, DOI DOI 10.1016/0956-9618(92)80008-2
[5]  
Everett D. H., 1958, STRUCTURE PROPERTIES, P95
[6]   EFFECT OF INTRAPARTICLE CONVECTION ON THE CHROMATOGRAPHY OF BIOMACROMOLECULES [J].
FREY, DD ;
SCHWEINHEIM, E ;
HORVATH, C .
BIOTECHNOLOGY PROGRESS, 1993, 9 (03) :273-284
[7]  
GREGG SJ, 1967, ADSORPTION SURFACE A
[8]   Multi-component perfusion chromatography in fixed bed and periodic counter current column operation [J].
Heeter, GA ;
Liapis, AI .
JOURNAL OF CHROMATOGRAPHY A, 1996, 734 (01) :105-123
[9]   Effects of structural and kinetic parameters on the performance of chromatographic columns packed with perfusive and purely diffusive adsorbent particles [J].
Heeter, GA ;
Liapis, AI .
JOURNAL OF CHROMATOGRAPHY A, 1996, 743 (01) :3-14
[10]   PERFUSION CHROMATOGRAPHY - PERFORMANCE OF PERIODIC COUNTERCURRENT COLUMN OPERATION AND ITS COMPARISON WITH FIXED-BED OPERATION [J].
HEETER, GA ;
LIAPIS, AI .