X-ray imaging with amorphous selenium: Optimal spectra for digital mammography

被引:30
作者
Fahrig, R
Rowlands, JA
Yaffe, MJ
机构
[1] UNIV TORONTO,DEPT MED IMAGING,TORONTO,ON M4N 3M5,CANADA
[2] SUNNYBROOK HLTH SCI CTR,DEPT MED IMAGING RES,TORONTO,ON M4N 3M5,CANADA
关键词
photoconductor; digital mammography; amorphous selenium; x-ray spectra;
D O I
10.1118/1.597688
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The optimum x-ray spectra for acquisition of digital mammographic images using an amorphous selenium (a-Se) photoconductor are investigated. The recorded images consist of latent charge distributions on the surface of an a-Se plate, which are then read out using two methods, laser discharge, or flat panel recharge. The investigation is based on a model of the breast previously developed for a phosphor-based digital readout system, and has been extended to include the effects specific to the use of photoconductors. The effects of plate thickness, x-ray scatter, readout noise, dose, and the kind of breast tissue on the nature of the optimum spectrum are explored for the two readout methods. The results indicate that use of a kilovoltage setting in the current mammographic range, and a molybdenum target spectrum is appropriate for digital readout of a-Se detectors. This conclusion contrasts with the appreciably higher kilovoltages traditionally used with the xerographic (toner) readout of latent charge images on a-Se. (C) 1996 American Association of Physicists in Medicine.
引用
收藏
页码:557 / 567
页数:11
相关论文
共 30 条
[1]  
BARRETT HH, 1981, RADIOLOGICAL IMAGING, P95
[2]  
BEVINGTON PR, 1969, DATA REDUCTION ERROR, P59
[3]   RADIOGRAPHIC INFORMATION-THEORY AND APPLICATION TO MAMMOGRAPHY [J].
BRODIE, I ;
GUTCHECK, RA .
MEDICAL PHYSICS, 1982, 9 (01) :79-95
[4]   MINIMUM ENTRANCE EXPOSURE ESTIMATES FOR INFORMATION RECORDING IN DIAGNOSTIC-RADIOLOGY [J].
BRODIE, I ;
GUTCHECK, RA .
MEDICAL PHYSICS, 1985, 12 (03) :362-367
[5]  
CHAN HP, 1988, MONTE CARLO SIMULATI, P149
[6]  
DANCE DR, 1981, P PATIENT EXPOSURE R, P227
[7]   X-RAY-IMAGING WITH AMORPHOUS SELENIUM - DETECTIVE QUANTUM EFFICIENCY OF PHOTOCONDUCTIVE RECEPTORS FOR DIGITAL MAMMOGRAPHY [J].
FAHRIG, R ;
ROWLANDS, JA ;
YAFFE, MJ .
MEDICAL PHYSICS, 1995, 22 (02) :153-160
[8]   A MODEL FOR OPTIMIZATION OF SPECTRAL SHAPE IN DIGITAL MAMMOGRAPHY [J].
FAHRIG, R ;
YAFFE, MJ .
MEDICAL PHYSICS, 1994, 21 (09) :1463-1471
[9]  
FAHRIG R, 1992, P SOC PHOTO-OPT INS, V1651, P74, DOI 10.1117/12.59405
[10]   OPTIMIZATION OF SPECTRAL SHAPE IN DIGITAL MAMMOGRAPHY - DEPENDENCE ON ANODE MATERIAL, BREAST THICKNESS, AND LESION TYPE [J].
FAHRIG, R ;
YAFFE, MJ .
MEDICAL PHYSICS, 1994, 21 (09) :1473-1481