Development of a novel hand-held formaldehyde gas sensor for the rapid detection of sick building syndrome

被引:179
作者
Kawamura, K
Kerman, K
Fujihara, M
Nagatani, N
Hashiba, T
Tamiya, E
机构
[1] Japan Adv Inst Sci & Technol, Dept Mat Sci, Nomi, Ishikawa 9231292, Japan
[2] Biomedia Co Ltd, Tokyo 1050013, Japan
关键词
formaldehyde; sick building syndrome; hand-held gas sensor; 4-amino hydrazine-5-mercapto-1,2,4-triazole (AHMT);
D O I
10.1016/j.snb.2004.07.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The majority of conventional sensors for monitoring formaldehyde (HCHO) in air have several drawbacks, in terms of sensitivity, selectivity. and sampling time. In this report, a novel hand-held HCHO gas sensor for the sick building syndrome (SBS) prevention and control is developed with a significantly short sampling time. A well-described reagent, 4-amino hydrazine-5-mercapto-1,2,4-triazole (AHMT) was utilized in the development of the novel gas sensor. AHMT of 100 mu 1 and potassium hydroxide solution were dropped on a circular filter by using a specially developed hanging drop kit. When the filter was exposed to HCHO gas at the rate of 400 ml/min, AHMT reagent on the filter reacted with HCHO to produce a change in its color. The color change was recorded by measuring the intensity of reflected light using a photodiode, which was illuminated by an LED at 540 nm. The response was defined as % of the voltage drop. The filter color intensity increased with sampling time in a concentration range of 0.04-1 ppm HCHO, and also the filter gave no response in the absence of HCHO. The limit-of-detection (LOD) of 0.04 ppm HCHO within a sampling time of 3 min was achieved. Thus, this method could be used to detect HCHO at the WHO standards (0.08 ppm) within 3 min. Moreover, our device did not respond to other SBS causing reagents, such as other aldehydes and volatile organic compounds. In conclusion, we have developed a rapid, selective and simple HCHO gas sensor for SBS, which is also a suitable device for on-field operations. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:495 / 501
页数:7
相关论文
共 17 条
[1]   A piezoelectric method for monitoring formaldehyde induced crosslink formation between poly-lysine and poly-deoxyguanosine [J].
Bunde, RL ;
Jarvi, EJ ;
Rosentreter, JJ .
TALANTA, 2000, 51 (01) :159-171
[2]  
Dickinson R. G., 1970, CHEM COMMUN, P1719
[3]  
DIRKSEN JA, 2001, SENSOR ACTUAT B-CHEM, P80
[4]   DETERMINATION OF NANOGRAM AMOUNTS OF CARBONYLS AS 2,4-DINITROPHENYLHYDRAZONES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
FUNG, K ;
GROSJEAN, D .
ANALYTICAL CHEMISTRY, 1981, 53 (02) :168-171
[5]   Measurement of indoor formaldehyde concentrations with a passive sampler [J].
Gillett, RW ;
Kreibich, H ;
Ayers, GP .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (10) :2051-2056
[6]   Electrochemical enzyme sensor for formaldehyde operating in the gas phase [J].
Hammerle, M ;
Hall, EAH ;
Cade, N ;
Hodgins, D .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (03) :239-246
[7]   Sensory eye irritation in humans exposed to mixtures of volatile organic compounds [J].
Hempel-Jorgensen, A ;
Kjærgaard, SK ;
Molhave, L ;
Hudnell, KH .
ARCHIVES OF ENVIRONMENTAL HEALTH, 1999, 54 (06) :416-424
[8]  
HERSCHKOVITZ Y, 2000, J ELECTROANAL CHEM, P491
[9]   A biosensor for monitoring formaldehyde using a new lipophilic tetrathiafulvalene-tetracyanoquinodimethane salt and a polyurethane membrane [J].
Kataky, R ;
Bryce, MR ;
Goldenberg, L ;
Hayes, S ;
Nowak, A .
TALANTA, 2002, 56 (03) :451-458
[10]   Effect of formaldehyde on the expression of adhesion molecules in nasal microvascular endothelial cells: the role of formaldehyde in the pathogenesis of sick building syndrome [J].
Kim, WJ ;
Terada, N ;
Nomura, T ;
Takahashi, R ;
Lee, SD ;
Park, JH ;
Konno, A .
CLINICAL AND EXPERIMENTAL ALLERGY, 2002, 32 (02) :287-295