Volumetric flow estimation in vivo and in vitro using pulsed-Doppler ultrasound

被引:21
作者
Holland, CK
Clancy, MJ
Taylor, KJW
Alderman, JL
Purushothaman, K
McCauley, TR
机构
[1] YALE UNIV,SCH MED,DEPT DIAGNOST RADIOL,NEW HAVEN,CT 06510
[2] BRISTOL ROYAL INFIRM & GEN HOSP,DEPT ACCID & EMERGENCY,BRISTOL,AVON,ENGLAND
关键词
volumetric flow estimation; flow measurement; Doppler ultrasound; flow model; flow phantom; Doppler flow cuff; blood flow; volume blood flow;
D O I
10.1016/0301-5629(96)00046-4
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The measurement of volumetric blood flow in small vessels in vitro and in vivo poses a significant technological challenge. In this study, two pulsatile how models were developed, one with a 3.2-mm lumen diameter and one with a 12.7-mm lumen diameter, to assess the accuracy of volumetric flow estimation of two pulsed-Doppler devices, a Crystal Biotech VF1 20-MHz system with either a cuff-mounted or a needle-mounted probe and an Advanced Technology Laboratories Ultramark 9 High Definition Imaging(R) system with a 5-MHz linear array transducer. The VF1 volumetric flow error was measured in the 3.2-mm phantom over a variety of pulsatile and continuous waveforms. The accuracy of the VF1 was also tested in porcine femoral and renal arteries. VF1 volumetric flow error ranged from 4.8% to 54.3% in the in vivo studies. The ATL demonstrated similar volumetric flow errors in the porcine femoral artery(similar to 3.2 mm diameter), but these errors were reduced to less than or equal to 17.4% in the 12.7-mm-diameter in vitro flow model.
引用
收藏
页码:591 / 603
页数:13
相关论文
共 27 条
[1]   PULSED ULTRASONIC DOPPLER BLOOD-FLOW SENSING [J].
BAKER, DW .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1970, SU17 (03) :170-&
[2]  
CLANCY M, 1992, RADIOLOGY, V185, P287
[3]   THE USE OF ULTRASOUND IN THE NONINVASIVE DETECTION OF CHANGES IN THE RENAL CIRCULATION IN RESPONSE TO BLOOD-LOSS USING AN ANIMAL-MODEL [J].
CLANCY, MJ ;
ALDERMAN, J ;
CASE, C ;
TAYLOR, KJW .
RESUSCITATION, 1995, 30 (02) :161-167
[4]   INFLUENCE OF BEAM PROFILE AND DEGREE OF INSONATION ON THE CW DOPPLER ULTRASOUND SPECTRUM AND MEAN VELOCITY [J].
COBBOLD, RSC ;
VELTINK, PH ;
JOHNSTON, KW .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1983, 30 (06) :364-370
[6]  
EVANS DH, 1989, DOPPLER ULTRASOUND P, P127
[7]  
Field JP., 1989, J VASC TECH, V13, P13
[8]  
GERZBERG L, 1977, ULTRASOUND MED B, V3, P173
[9]  
GILL R W, 1979, Ultrasound in Medicine and Biology, V5, P237, DOI 10.1016/0301-5629(79)90015-2