Non-invasive quantification of small bowel water content by MRI: a validation study

被引:74
作者
Hoad, C. L. [1 ]
Marciani, L. [2 ]
Foley, S. [2 ]
Totman, J. J. [3 ]
Wright, J. [4 ]
Bush, D. [4 ]
Cox, E. F. [1 ]
Campbell, E. [2 ]
Spiller, R. C. [2 ]
Gowland, P. A. [1 ]
机构
[1] Univ Nottingham, Sch Phys & Astron, Sir Peter Mansfield Magnet Resonance Ctr, Nottingham NG7 2RD, England
[2] Univ Nottingham Hosp, QMC, Wolfson Digest Dis Ctr, Nottingham NG7 2UH, England
[3] Univ Nottingham, Brain & Body Ctr, Nottingham NG7 2RD, England
[4] Univ Nottingham, Univ Nottingham Hosp, QMC, Div GI Surg, Nottingham NG7 2RD, England
关键词
D O I
10.1088/0031-9155/52/23/009
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Substantial water fluxes across the small intestine occur during digestion of food, but so far measuring these has required invasive intubation techniques. This paper describes a non-invasive magnetic resonance imaging (MRI) technique for measuring small bowel water content which has been validated using naso-duodenal infusion. Eighteen healthy volunteers were intubated, with the tube position being verified by MRI. After a baseline MRI scan, each volunteer had eight 40 ml boluses of a non-absorbable mannitol and saline solution infused into their proximal small bowel with an MRI scan being acquired after each bolus. The MRI sequence used was an adapted magnetic resonance cholangiopancreatography sequence. The image data were thresholded to allow for intra- and inter-subject signal variations. The MRI measured volumes were then compared to the known infused volumes. This MRI technique gave excellent images of the small bowel, which closely resemble those obtained using conventional radiology with barium contrast. The mean difference between the measured MRI volumes and infused volumes was 2% with a standard deviation of 10%. The maximum 95% limits of agreement between observers were -15% to +17% while measurements by the same operator on separate occasions differed by only 4%. This new technique can now be applied to study alterations in small bowel fluid absorption and secretion due to gastrointestinal disease or drug intervention.
引用
收藏
页码:6909 / 6922
页数:14
相关论文
共 33 条
[1]
ECHO-PLANAR MAGNETIC-RESONANCE-IMAGING TO ASSESS WATER VOLUME IN THE DISTAL SMALL-BOWEL [J].
ADKIN, DA ;
GOWLAND, P ;
SPILLER, RC ;
FREEMAN, A ;
HYKIN, J ;
ISSA, B ;
HUCKLE, PD ;
WILDING, IR .
PHARMACEUTICAL RESEARCH, 1995, 12 (08) :1134-1139
[2]
Barish MA, 1996, TOP MAGN RESON IMAG, V8, P302
[3]
Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[4]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]
FAST T-2-MAPPING WITH SNAPSHOT FLASH IMAGING [J].
DEICHMANN, R ;
ADOLF, H ;
NOTH, U ;
MORRISSEY, S ;
SCHWARZBAUER, C ;
HAASE, A .
MAGNETIC RESONANCE IMAGING, 1995, 13 (04) :633-639
[6]
EFFECT OF PECTIN ON JEJUNAL GLUCOSE-ABSORPTION AND UNSTIRRED LAYER THICKNESS IN NORMAL MAN [J].
FLOURIE, B ;
VIDON, N ;
FLORENT, C ;
BERNIER, JJ .
GUT, 1984, 25 (09) :936-941
[7]
In vivo imaging of intragastric gelation and its effect on satiety in humans [J].
Hoad, CL ;
Rayment, P ;
Spiller, RC ;
Marciani, L ;
Alonso, BD ;
Traynor, C ;
Mela, DJ ;
Peters, HPF ;
Gowland, PA .
JOURNAL OF NUTRITION, 2004, 134 (09) :2293-2300
[8]
HYKIN J, 1994, MAGN RESON MATER PHY, V2, P471, DOI 10.1007/BF01705300
[9]
ACTIVE AND PASSIVE BILE-ACID ABSORPTION IN MAN - PERFUSION STUDIES OF ILEUM AND JEJUNUM [J].
KRAG, E ;
PHILLIPS, SF .
JOURNAL OF CLINICAL INVESTIGATION, 1974, 53 (06) :1686-1694
[10]
Effect of ingestion order of the fat component of a solid meal on intragastric fat distribution and gastric emptying assessed by MRI [J].
Kunz, P ;
Feinle-Bisset, C ;
Faas, H ;
Boesiger, P ;
Fried, M ;
Steingötter, A ;
Schwizer, W .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (04) :383-390