Finite element analysis of trabecular bone structure:: a comparison of image-based meshing techniques

被引:210
作者
Ulrich, D
van Rietbergen, B
Weinans, H
Rüegsegger, P
机构
[1] Univ Zurich, Inst Biomed Engn, Zurich, Switzerland
[2] Swiss Fed Inst Technol, Zurich, Switzerland
[3] Erasmus Univ, Dept Orthopaed, Rotterdam, Netherlands
关键词
finite element analysis; trabecular bone structure; meshing; CT imaging; mechanical properties;
D O I
10.1016/S0021-9290(98)00118-3
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this study, we investigate if finite element (FE) analyses of human trabecular bone architecture based on 168 mu m images can provide relevant information about the bone mechanical characteristics. Three human trabecular bone samples, one taken from the femoral head, one from the iliac crest, and one from the lumbar spine, were imaged with micro-computed tomography (micro-CT) using a 28 mu m resolution. After reconstruction the resolution was coarsened to 165 mu m. First, all reconstructions were thresholded and directly converted to FE-models built of hexahedral elements. For the coarser resolutions of two samples, this resulted in a loss of trabecular connections and a subsequent loss of stiffness. To reduce this effect, a tetrahedral element meshing based on the marching cubes algorithm, as well as a modified hexahedron meshing, which thresholds the image such that load carrying bone mass is preserved, were employed. For each sample elastic moduli and tissue Von Mises stresses of the three different 168 mu m models were compared to those from the hexahedron 28 mu m model. For one sample the hexahedron meshing at 168 mu m produced excellent results. For the other two samples the results obtained from the hexahedral models at 168 mu m resolution were poor. Considerably better results were attained for these samples when using the mass-compensated or tetrahedron meshing techniques. We conclude that the accuracy of the FE-models at 168 mu m strongly depends on the bone morphology, in particular its trabecular thickness. A substantial loss of trabecular connections during the hexahedron meshing process indicates that poor FE results will be obtained. In this case the tetrahedron or mass-compensated hexahedron meshing techniques can reduce the loss of connections and produce better results than the plain hexahedron meshing techniques. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1187 / 1192
页数:6
相关论文
共 17 条
[1]   COMPRESSIVE BEHAVIOR OF BONE AS A 2-PHASE POROUS STRUCTURE [J].
CARTER, DR ;
HAYES, WC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (07) :954-962
[2]   THE DIRECT EXAMINATION OF 3-DIMENSIONAL BONE ARCHITECTURE INVITRO BY COMPUTED-TOMOGRAPHY [J].
FELDKAMP, LA ;
GOLDSTEIN, SA ;
PARFITT, AM ;
JESION, G ;
KLEEREKOPER, M .
JOURNAL OF BONE AND MINERAL RESEARCH, 1989, 4 (01) :3-11
[3]   FULLY-AUTOMATIC MESH GENERATION FOR 3-D DOMAINS BASED UPON VOXEL SETS [J].
FREY, P ;
SARTER, B ;
GAUTHERIE, M .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 1994, 37 (16) :2735-2753
[4]  
FYHRIE DP, 1993, T 39 ANN M ORTH RES
[5]   A HOMOGENIZATION SAMPLING PROCEDURE FOR CALCULATING TRABECULAR BONE EFFECTIVE STIFFNESS AND TISSUE-LEVEL STRESS [J].
HOLLISTER, SJ ;
BRENNAN, JM ;
KIKUCHI, N .
JOURNAL OF BIOMECHANICS, 1994, 27 (04) :433-444
[6]  
Majumdar S, 1997, ST HEAL T, V40, P81
[7]   NONINVASIVE BONE-BIOPSY - A NEW METHOD TO ANALYZE AND DISPLAY THE 3-DIMENSIONAL STRUCTURE OF TRABECULAR BONE [J].
MULLER, R ;
HILDEBRAND, T ;
RUEGSEGGER, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (01) :145-164
[8]  
MULLER R, 1995, J MED ENG PHYS, V17, P126
[9]   THE UNDERESTIMATION OF YOUNG MODULUS IN COMPRESSIVE TESTING OF CANCELLOUS BONE SPECIMENS [J].
ODGAARD, A ;
LINDE, F .
JOURNAL OF BIOMECHANICS, 1991, 24 (08) :691-698
[10]   A DIRECT METHOD FOR FAST 3-DIMENSIONAL SERIAL RECONSTRUCTION [J].
ODGAARD, A ;
ANDERSEN, K ;
MELSEN, F ;
GUNDERSEN, HJG .
JOURNAL OF MICROSCOPY, 1990, 159 :335-342