Application of high-surface-area ZrO2 in preconcentration and determination of 18 elements by on-line flow injection with inductively coupled plasma atomic emission spectrometry

被引:103
作者
Vassileva, E [1 ]
Furuta, N [1 ]
机构
[1] Chuo Univ, Fac Sci & Engn, Dept Appl Chem, Bunkyo Ku, Tokyo 1128551, Japan
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2001年 / 370卷 / 01期
关键词
D O I
10.1007/s002160100744
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-injection analysis (FIA) system incorporating a micro-column of ZrO2 has been used for the development of an on-line multi-element method for the simultaneous preconcentration and determination of Al, Bi, Cd, Co, Cr, Cu, Fe, Ga, In, Mn, Mo, Ni, Pb, Tl, V, Sb, Sn, and Zn by inductively coupled plasma atomic emission spectrometry (ICP-AES). The conditions for quantitative and reproducible preconcentration, elution, and subsequent on-line ICP-AES determination were established. A sample (pH 8) is pumped through the column at 3 mL min(-1) and sequentially eluted directly into the ICP-AES with 3 mol L-1 HNO3. With a sample volume of 100 mL and an elution volume of 1 mL signal enhancement 100 times better than for conventional continuous aspirating systems was obtained for the elements studied. The reproducibility (RSD %) Of the method at the 10 ng mL(-1) level in the eluate is acceptable - less than 8% for five replicates. Recoveries between 95.4% and 99.9% were obtained for the elements analysed. ZrO2, with a specific surface area of 57 m(2) g(-1) and a capacity of approximately 5 mg g(-1) for the elements studied, was synthesized by hydrolysis of ZrCl4. The preconcentration system was evaluated for several simple synthetic matrices, standard water samples and synthetic seawater. The effect of foreign ions on the efficiency of preconcentration of the elements studied was investigated. The application of a micro-column filled with high-surface-area ZrO2 and flow injection inductively coupled plasma atomic emission spectrometry enables preconcentration and simultaneous determination of 18 elements at low concentrations (ng L-1) in different water samples.
引用
收藏
页码:52 / 59
页数:8
相关论文
共 31 条
[1]   EFFECT OF FORM ON THE SURFACE-CHEMISTRY OF FINELY DIVIDED SOLIDS [J].
BOLIS, V ;
FUBINI, B ;
GIAMELLO, E .
MATERIALS CHEMISTRY AND PHYSICS, 1991, 29 (1-4) :153-164
[2]   SEPARATION OF METAL-IONS ON A MODIFIED ALUMINUM-OXIDE [J].
BRAJTER, K ;
DABEKZLOTORZYNSKA, E .
TALANTA, 1990, 37 (06) :613-618
[3]  
BRUNELLE JP, 1978, P 2 INT S PREP CAT L
[4]  
Davydov A.A., 1984, IR SPECTROSCOPY APPL
[5]   EXCHANGE OF 20 METAL IONS WITH WEAKLY ACIDIC SILANOL GROUP OF SILICA GEL [J].
DUGGER, DL ;
STANTON, JH ;
MCCONNEL.BL ;
IRBY, BN ;
CUMMINGS, WW ;
MAATMAN, RW .
JOURNAL OF PHYSICAL CHEMISTRY, 1964, 68 (04) :757-&
[6]   DETERMINATION OF ARSENIC, CHROMIUM, SELENIUM AND VANADIUM IN BIOLOGICAL SAMPLES BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY USING ONLINE ELIMINATION OF INTERFERENCE AND PRECONCENTRATION BY FLOW-INJECTION [J].
EBDON, L ;
FISHER, AS ;
WORSFOLD, PJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (05) :611-614
[7]   FLOW-INJECTION ONLINE SORBENT EXTRACTION PRECONCENTRATION FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
FANG, Z ;
SPERLING, M ;
WELZ, B .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (07) :639-646
[8]   Developments and trends in flow injection atomic absorption spectrometry [J].
Fang, ZL ;
Xu, SK ;
Tao, GH .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (01) :1-24
[9]  
FANG ZL, 1991, SPECTROCHIM ACTA REV, V14, P235
[10]   ADSORPTION OF COPPER, NICKEL, AND COBALT BY OXIDE ADSORBENTS FROM AQUEOUS AMMONIACAL SOLUTIONS [J].
FUERSTENAU, DW ;
OSSEOASARE, K .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1987, 118 (02) :524-542