When good water goes bad: How it happens, clinical consequences and possible solutions

被引:25
作者
Lonnemann, G [1 ]
机构
[1] Gemeinschaftspraxis Nephrol Dialysis, DE-30851 Langenhagen, Germany
关键词
biofilm; carpal tunnel syndrome; cytokines; dialysis fluid; quality; endotoxins; inflammation; malnutrition-inflammation atherosclerosis; pyrogens; ultrafilters;
D O I
10.1159/000074932
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Dialysis fluid produced by state-of-the-art water preparation and distribution is contaminated with gram-negative bacteria and cytokine-inducing substances (CIS) derived from these microorganisms. The presence of a biofilm increases the risk of continuous contamination of dialysis fluid. Depending on the type of dialyzer membrane (cellulosic vs. synthetic) and the mode of dialysis (low flux vs. high flux with backfiltration), CIS may penetrate intact dialyzer membranes, induce cytokine production in the patient's blood and contribute to chronic inflammation associated with long-term hemodialysis therapy. Measures to improve the microbiological quality of dialysis fluid are: (1) the awareness of the problem and regular testing of dialysate samples using adequate methods; (2) disinfection of the entire water preparation and distribution system on a regular basis, replacement of biofilm-containing tubings, and (3) installation of ultrafilters in the dialysate circuit in particular when high-flux hemodialysis modalities are performed. Copyright (C) 2004 S. Karger AG, Basel.
引用
收藏
页码:124 / 129
页数:6
相关论文
共 21 条
[1]   USING ULTRAPURE WATER IN HEMODIALYSIS DELAYS CARPAL-TUNNEL SYNDROME [J].
BAZ, M ;
DURAND, C ;
RAGON, A ;
JABER, K ;
ANDRIEU, D ;
MERZOUK, T ;
PURGUS, R ;
OLMER, M ;
REYNIER, JP ;
BERLAND, Y .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1991, 14 (11) :681-685
[2]  
Bommer J, 1996, J AM SOC NEPHROL, V7, P883
[3]   ULTRAFILTRATION TO REJECT HUMAN INTERLEUKIN-1-INDUCING SUBSTANCES DERIVED FROM BACTERIAL CULTURES [J].
DINARELLO, CA ;
LONNEMANN, G ;
MAXWELL, R ;
SHALDON, S .
JOURNAL OF CLINICAL MICROBIOLOGY, 1987, 25 (07) :1233-1238
[4]   Effect of dialysis dose and membrane flux in maintenance hemodialysis. [J].
Eknoyan, G ;
Beck, GJ ;
Cheung, AK ;
Daugirdas, JT ;
Greene, T ;
Kusek, JW ;
Allon, M ;
Bailey, J ;
Delmez, JA ;
Depner, TA ;
Dwyer, JT ;
Levey, AS ;
Levin, NW ;
Milford, E ;
Ornt, DB ;
Rocco, MV ;
Schulman, G ;
Schwab, SJ ;
Teehan, BP ;
Toto, R .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 347 (25) :2010-2019
[5]  
JONES BW, 2001, ANN RHEUM DIS S3, V60, pR6
[6]   Long-term experience with an ultrapure individual dialysis fluid with a batch type machine [J].
Kleophas, W ;
Haastert, B ;
Backus, G ;
Hilgers, P ;
Westhoff, A ;
van Endert, G .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 (12) :3118-3125
[7]   Switch from conventional to high-flux membrane reduces the risk of carpal tunnel syndrome and mortality of hemodialysis patients [J].
Koda, Y ;
Nishi, S ;
Miyazaki, S ;
Haginoshita, S ;
Sakurabayashi, T ;
Suzuki, M ;
Sakai, S ;
Yuasa, Y ;
Hirasawa, Y ;
Nishi, T .
KIDNEY INTERNATIONAL, 1997, 52 (04) :1096-1101
[8]   Defining the microbiological quality of dialysis fluid [J].
Ledebo, I ;
Nystrand, R .
ARTIFICIAL ORGANS, 1999, 23 (01) :37-43
[9]   Assessment of the quality of dialysate [J].
Lonnemann, G .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 :17-20
[10]  
Lonnemann G, 2002, J AM SOC NEPHROL, V13, pS72