Simultaneous and sequential same-arm measurements in the validation studies of automated blood pressure measuring devices

被引:8
作者
Livi, R
Teghini, L
Cagnoni, S
Scarpelli, PT
机构
[1] Institute of Clinical Medicine IV, Department of Electronic Engineering, University of Florence, Florence
[2] Institute of Clinical Medicine IV, University of Florence, I-50139 Firenze
关键词
blood pressure; ambulatory monitoring; validation; British Hypertension Society protocol; Daypress; 500;
D O I
10.1016/S0895-7061(96)00320-2
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
The oscillometric ambulatory blood pressure recorder Daypress 500 was validated according to the British Hypertension Society protocol. Both sequential and simultaneous measurements were used. Multiple regression analysis demonstrated a significant influence of subject pulse pressure and arm circumference on device-observer systolic pressure differences. Differences between observer consecutive readings were inversely related to heart rate. Device and observer blood pressure readings were closer at simultaneous than at sequential measurements. However, both kinds of measurement led to the same final evaluation (A for diastolic and B for systolic blood pressure), provided that the appropriate grading criteria were applied for each method. (C) 1996 American Journal of Hypertension, Ltd.
引用
收藏
页码:1228 / 1231
页数:4
相关论文
共 9 条
[1]  
[Anonymous], 1987, AM NAT STAND EL AUT
[2]  
ATKINS N, 1990, J HUM HYPERTENS, V4, P647
[3]  
CATES EM, 1990, J AMB MONITORING, V2, P149
[4]   BRITISH HYPERTENSION PROTOCOL [J].
COATS, AJS ;
CLARK, SJ .
JOURNAL OF HYPERTENSION, 1991, 9 (06) :575-576
[5]   THE BRITISH-HYPERTENSION-SOCIETY PROTOCOL FOR THE EVALUATION OF AUTOMATED AND SEMIAUTOMATED BLOOD-PRESSURE MEASURING DEVICES WITH SPECIAL REFERENCE TO AMBULATORY SYSTEMS [J].
OBRIEN, E ;
PETRIE, J ;
LITTLER, W ;
DESWIET, M ;
PADFIELD, PL ;
OMALLEY, K ;
JAMIESON, M ;
ALTMAN, D ;
BLAND, M ;
ATKINS, N .
JOURNAL OF HYPERTENSION, 1990, 8 (07) :607-619
[6]  
OBRIEN E, 1994, J HYPERTENS, V12, P1089
[7]   THE BRITISH-HYPERTENSION-SOCIETY PROTOCOL FOR THE EVALUATION OF AUTOMATED AND SEMIAUTOMATED BLOOD-PRESSURE MEASURING DEVICES WITH SPECIAL REFERENCE TO AMBULATORY SYSTEMS [J].
OBRIEN, E ;
PETRIE, J ;
LITTLER, W ;
DESWIET, M ;
PADFIELD, PL ;
OMALLEY, K ;
JAMIESON, M ;
ALTMAN, D ;
BLAND, M ;
ATKINS, N .
JOURNAL OF HYPERTENSION, 1990, 8 (07) :607-619
[8]  
PANNARALE G, 1993, HYPERTENSION, V22, P59
[9]   NATIONAL STANDARD FOR MEASUREMENT OF RESTING AND AMBULATORY BLOOD PRESSURES WITH AUTOMATED SPHYGMOMANOMETERS [J].
WHITE, WB ;
BERSON, AS ;
ROBBINS, C ;
JAMIESON, MJ ;
PRISANT, LM ;
ROCCELLA, E ;
SHEPS, SG .
HYPERTENSION, 1993, 21 (04) :504-509