The Quantitative Assessment of Risk Factors to Overstress at Adjacent Segments After Lumbar Fusion Removal of Posterior Ligaments and Pedicle Screws

被引:50
作者
Kim, Ho-Joong [1 ,2 ]
Kang, Kyoung-Tak [3 ,4 ]
Moon, Seong-Hwan [1 ]
Chun, Heoung-Jae [3 ]
Kim, Hak-Sun [1 ]
Park, Jin-Oh [1 ]
Moon, Eun-Su [1 ]
Kim, Bo-Ram [1 ]
Sohn, Joon-Seok [2 ]
Lee, Hwan-Mo [1 ]
机构
[1] Yonsei Univ, Coll Med, Dept Orthopaed Surg, Seoul, South Korea
[2] Yonse Sarang Hosp, Spire Ctr, Seoul, South Korea
[3] Yonsei Univ, Dept Mech Engn, Seoul 120749, South Korea
[4] Korea Bone Bank Co Ltd, Inst Biomat & Med Engn, Seoul, South Korea
关键词
adjacent segment deterioration; pedicle screws; posterior ligament complex; finite element model; FINITE-ELEMENT-ANALYSIS; INTERBODY FUSION; SPINAL INSTRUMENTATION; LUMBOSACRAL FUSION; STRESS-ANALYSIS; DEGENERATION; DISC; FIXATION; MOTION; LAMINECTOMY;
D O I
10.1097/BRS.0b013e318221a595
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
Study Design. Finite element method. Objective. To investigate the changes in the disc stress and range of motion (ROM) at adjacent segments after lumbar fusion based on whether or not pedicle screws are removed and whether or not the continuity of the proximal posterior ligament complex (PLC) is preserved. Summary of Background Data. The ablation of proximal PLC continuity and the presence of pedicle screws have been reported to affect the biomechanics at adjacent segments after lumbar fusion. However, there have been few studies regarding the quantitative assessment of their contribution to overstress at adjacent segments after lumbar fusion. Methods. In the validated intact lumbar finite element model (L2-L5), four types of L3-L4 fusion models were simulated. These models included the preservation of the PLC continuity with pedicle screws (Pp WiP), the preservation of PLC continuity without pedicle screws (Pp WoP), the sacrifice of PLC with pedicle screws (Sp WiP), and the sacrifice of PLC without pedicle screws (Sp WoP). In each scenario, the ROM, maximal von Mises stress of discs, and the facet joint contract force at adjacent segments were analyzed. Results. Among the four models, the Sp WiP yielded the greatest increase in the ROM and the maximal von Mises stress of the disc at adjacent segments under four moments. Following the SP WiP, the order of increase of the ROM and the disc stress was Pp WiP, Sp WoP, and Pp WoP. Furthermore, the increase of ROM and disc stress at the proximal adjacent segment was more than at the distal adjacent segment under all four moments in each model. The facet joint contact was also most increased in the Sp WiP under extension and torsion moment. Conclusion. The current study suggests that the preservation of the PLC continuity or the removal of pedicle screws after complete fusion could decrease the stress at adjacent segments, and their combination could act synergistically.
引用
收藏
页码:1367 / 1373
页数:7
相关论文
共 25 条
[1]
THE EFFECT OF POSTURE ON THE ROLE OF THE APOPHYSEAL JOINTS IN RESISTING INTERVERTEBRAL COMPRESSIVE FORCES [J].
ADAMS, MA ;
HUTTON, WC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1980, 62 (03) :358-362
[2]
Residual sagittal motion after lumbar fusion - A finite element analysis with implications on radiographic flexion-extension criteria [J].
Bono, Christopher M. ;
Khandha, Ashutosh ;
Vadapalli, S. ;
Holekamp, Scott ;
Goel, Vijay K. ;
Garfin, Steven R. .
SPINE, 2007, 32 (04) :417-422
[3]
Does Superior-Segment Facet Violation or Laminectomy Destabilize the Adjacent Level in Lumbar Transpedicular Fixation? [J].
Cardoso, Mario J. ;
Dmitriev, Anton E. ;
Helgeson, Melvin ;
Lehman, Ronald A. ;
Kuklo, Timothy R. ;
Rosner, Michael K. .
SPINE, 2008, 33 (26) :2868-2873
[4]
Chen CS, 2001, MED ENG PHYS, V23, P483
[5]
AN ANALYTICAL INVESTIGATION OF THE MECHANICS OF SPINAL INSTRUMENTATION [J].
GOEL, VK ;
KIM, YE ;
LIM, TH ;
WEINSTEIN, JN .
SPINE, 1988, 13 (09) :1003-1011
[6]
Effects of Charite artificial disc on the implanted and adjacent spinal segments mechanics using a hybrid testing protocol [J].
Goel, VK ;
Grauer, JN ;
Patel, TC ;
Biyani, A ;
Sairyo, K ;
Vishnubhotla, S ;
Matyas, A ;
Cowgill, I ;
Shaw, M ;
Long, R ;
Dick, D ;
Panjabi, MM ;
Serhan, H .
SPINE, 2005, 30 (24) :2755-2764
[7]
Validation of a clinical finite element model of the human lumbosacral spine [J].
Guan, Yabo ;
Yoganandan, Narayan ;
Zhang, Jiangyue ;
Pintar, Frank A. ;
Cusick, Joesph F. ;
Wolfla, Christopher E. ;
Maiman, Dennis J. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2006, 44 (08) :633-641
[8]
Bone Graft Volumetric Changes and Clinical Outcomes After Instrumented Lumbar or Lumbosacral Fusion A Prospective Cohort Study With a Five-Year Follow-up [J].
Ha, Kee-Yong ;
Lee, Jun-Seok ;
Kim, Ki-Won .
SPINE, 2009, 34 (16) :1663-1668
[9]
Lumbar adjacent segment degeneration and disease after arthrodesis and total disc arthroplasty [J].
Harrop, James S. ;
Youssef, Jim A. ;
Maltenfort, Mitch ;
Vorwald, Peggy ;
Jabbour, Pascal ;
Bono, Christopher M. ;
Goldfarb, Neil ;
Vaccaro, Alexander R. ;
Hilibrand, Alan S. .
SPINE, 2008, 33 (15) :1701-1707
[10]
Kim HC, 2010, MED BIOL ENG COMPUT