Fourier transform ion cyclotron resonance mass spectrometry using atmospheric pressure photoionization for high-resolution analyses of corticosteroids

被引:31
作者
Greig, MJ [1 ]
Bolaños, B [1 ]
Quenzer, T [1 ]
Bylund, JMR [1 ]
机构
[1] Pfizer Global Res & Dev, La Jolla Labs, San Diego, CA 92121 USA
关键词
D O I
10.1002/rcm.1257
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) was coupled with atmospheric pressure photoionization (APPI) for the first time and used for the analysis of several corticosteroids.(1) The analytes showed excellent response using APPI when compared with both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI). APPI has the advantage of requiring less heat for desolvation, resulting in less thermal degradation of the analytes and higher signal-to-noise than APCI. In terms of ultimate sensitivity, APPI is more efficient than either ESI or APCI for the analysis of corticosteroids. With some compounds, the high-resolution capability of FTICRMS was necessary to obtain an accurate mass due to contributions of the M+ C-13 isotope in the [M+H](+) ion peak. Copyright (C) 2003 John Wiley Sons, Ltd.
引用
收藏
页码:2763 / 2768
页数:6
相关论文
共 26 条
[1]  
Borts DJ, 2000, J MASS SPECTROM, V35, P50, DOI 10.1002/(SICI)1096-9888(200001)35:1<50::AID-JMS912>3.0.CO
[2]  
2-J
[3]  
CORMIA PH, 2001, P 49 ASMS C MASS SPE
[4]   A high-performance liquid chromatography electrospray tandem mass spectrometry analysis of cortisol and metabolites in placental perfusate [J].
Dodds, HM ;
Taylor, PJ ;
Cannell, GR ;
Pond, SM .
ANALYTICAL BIOCHEMISTRY, 1997, 247 (02) :342-347
[5]   Identification of main corticosteroids as illegal feed additives in milk replacers by liquid chromatography atmospheric pressure chemical ionisation mass spectrometry [J].
Fiori, M ;
Pierdominici, E ;
Longo, F ;
Brambilla, G .
JOURNAL OF CHROMATOGRAPHY A, 1998, 807 (02) :219-227
[6]  
GREIG M, 2003, 4 N AM FOUR TRANSF I
[7]  
HANOLD KA, 2001, P 49 ASMS C MASS SPE
[8]  
HANOLD KA, 2002, P 50 ASMS C MASS SPE
[9]   High-performance liquid chromatography-atmospheric pressure photoionization/tandem mass spectrometric analysis for small molecules in plasma [J].
Hsieh, YS ;
Merkle, K ;
Wang, GF ;
Brisson, JM ;
Korfmacher, WA .
ANALYTICAL CHEMISTRY, 2003, 75 (13) :3122-3127
[10]   Liquid chromatography/mass spectrometry in anabolic steroid analysis-optimization and comparison of three ionization techniques: electrospray ionization, atmospheric pressure chemical ionization and atmospheric pressure photoionization [J].
Leinonen, A ;
Kuuranne, T ;
Kostiainen, R .
JOURNAL OF MASS SPECTROMETRY, 2002, 37 (07) :693-698