Modeling of DFIG-Based Wind Turbine for Power System Transient Response Analysis in Rotor Speed Control Timescale

被引:175
作者
Tang, Wangqianyun [1 ,2 ]
Hu, Jiabing [1 ,2 ]
Chang, Yuanzhu [1 ,2 ]
Liu, Feng [3 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Hubei, Peoples R China
[2] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, Wuhan 430074, Hubei, Peoples R China
[3] Tsinghua Univ, State Key Lab Power Syst, Dept Elect Engn & Appl Elect Technol, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Doubly fed induction generator (DFIG); DFIG-based WT-dominated power system; modeling; transient response; transient stability analysis; STABILITY ANALYSIS; FAULT;
D O I
10.1109/TPWRS.2018.2827402
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
080906 [电磁信息功能材料与结构]; 082806 [农业信息与电气工程];
摘要
The transient responses and stability followed by grid faults of the modern power systems experience diverse changes and have created concerns, especially for those dominated by doubly fed induction generator (DFIG) based wind turbines (WTs), since the transient characteristics of the DFIG-based WT are totally different from those of a synchronous generator (SG). To physically understand the transient response and theoretically analyze the transient stability of DFIG-based WT, this paper proposes a magnitude/phase dynamical model with synthetical consideration on the controllers in the rotor speed control timescale (around seconds). The proposed model physically explains the relationship between the imbalanced active power as well as the output active/reactive powers themselves and the DFIG-based WT's internal voltage vector, whose form is similar to that of the SG. By comparing with the SG, the distinctive transient phase characteristics of the DFIG-based WT are illustrated. An additional phase limitation is found, exceeding which the operation point does not exist. Based on the proposed model, the transient stability of a simple DFIG-based WT-dominated system is theoretically analyzed, and a new instability phenomenon different from that in an SG-dominated system is identified. Furthermore, some key factors influencing the transient stability are discussed.
引用
收藏
页码:6795 / 6805
页数:11
相关论文
共 29 条
[1]
Abad G., 2011, DOUBLY FED INDUCTION, V85
[2]
Ackermann T, 2005, WIND POWER IN POWER SYSTEMS, P1, DOI 10.1002/0470012684
[3]
Anderson PM, 1977, Power system control and stabilityJ
[4]
[Anonymous], 2016, P CSEE
[5]
[Anonymous], MODELING GE WIND TUR
[6]
Comparative study on fault responses of synchronous generators and wind turbine generators using transient stability index based on transient energy function [J].
Chowdhury, M. A. ;
Hosseinzadeh, N. ;
Shen, W. X. ;
Pota, H. R. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2013, 51 :145-152
[7]
Ela E., 2014, TP5D0060574 NAT REN
[8]
Fouad A.-A., 1991, Power system transient stability analysis using the transient energy function method
[9]
Impact of Increased Penetration of DFIG-Based Wind Turbine Generators on Transient and Small Signal Stability of Power Systems [J].
Gautam, Durga ;
Vittal, Vijay ;
Harbour, Terry .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2009, 24 (03) :1426-1434
[10]
Input-admittance calculation and shaping for controlled voltage-source converters [J].
Harnefors, Lennart ;
Bongiorno, Massimo ;
Lundberg, Stefan .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2007, 54 (06) :3323-3334