Correlation between the tissue Doppler, strain rate, strain imaging during the dobutamine infusion and coronary fractional flow reserve during catheterization: a comparative study

被引:12
作者
Dagdelen, S
Yuce, M
Emiroglu, Y
Ergelen, M
Pala, S
Tanalp, AC
Izgi, A
Kirma, C
机构
[1] Acibadem Hastanesi, Istanbul, Turkey
[2] Kosuyolu Heart & Res Hosp, Istanbul, Turkey
关键词
stress echocardiography; strain rate; coronary flow reserve;
D O I
10.1016/j.ijcard.2004.05.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Coronary fractional flow reserve (FFR) as an invasive, and dobutamine stress echocardiography (DSE) as a noninvasive technique were used to detect critical coronary stenosis. This study was undertaken to assess correlation between these two techniques by using tissue Doppler, strain rate (SR), and strain imaging (S). Methods: In 17 patients (aged 54.9 +/- 12.6, 4 F), a total of 22 vessels were studied. On dobutamine stress echocardiography, baseline and peak systolic (Sm), early (Em) and late (Am) diastolic myocardial velocities, SR and S were recorded from parasternal view (mid-posterior segment) for radial and apical view (mid-septum) for longitudinal deformation. Then coronary FFR was performed by using intracoronary adenosine infusion, and the value of <= 0.75 was accepted as critical coronary stenosis. Results: FFR was found to be significant in 10 vessels (FFR critical). Baseline Sm, Em/Am, SR, S values, and peak Em/Am, SR, S values were similar between critical or noncritical FFR groups. Baseline Sm and Em, and change between baseline and peak Sm and S were significantly higher in noncritical FFR group (p < 0.01, < 0.05, < 0.001, < 0.001, respectively). In all vessels, FFR after adenosine infusion showed a poor correlation with WMSI, Em, Am, Em/Am values, and the change in SR values (r=-0.22, 0.16, -0.14, 0.21, 18, respectively) showed a good correlation with the change in S (r=0.51; p=0.014), and a very good correlation with the change in Sm values (r=0.77; p < 0.001) during DSE. When FFR values at left coronary system were analyzed for longitudinal SR and S values, it had a mild correlation with SR (r=0.47 p=0.044) and a good correlation with S (r=0.66, p=0.002). Conclusion: The quantification of regional myocardial deformation by using DSE rather than the motion would be more appropriate in detecting the ischemic dysfunctional segment supplied by the critical coronary stenosis. Strain measurement during the dobutamine infusion may provide an information on the FFR results of the culprit vessel. (c) 2004 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:127 / 136
页数:10
相关论文
共 32 条
  • [1] Time to onset of regional relaxation: Feasibility, variability and utility of a novel index of regional myocardial function by strain rate imaging
    Abraham, TP
    Belohlavek, M
    Thomson, HL
    Pislaru, C
    Khandheria, B
    Seward, JB
    Pellikka, PA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (09) : 1531 - 1537
  • [2] Use of peak systolic strain as an index of regional left ventricular function: Comparison with tissue Doppler velocity during dobutamine stress and myocardial ischemia
    Armstrong, G
    Pasquet, A
    Fukamachi, K
    Cardon, L
    Olstad, B
    Marwick, T
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2000, 13 (08) : 731 - 737
  • [3] QUANTITATIVE CORONARY ANGIOGRAPHY IN PREDICTING FUNCTIONAL-SIGNIFICANCE OF STENOSES IN AN UNSELECTED PATIENT COHORT
    BARTUNEK, J
    SYS, SU
    HEYNDRICKX, GR
    PIJLS, NHJ
    DEBRUYNE, B
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (02) : 328 - 334
  • [4] Atrioventricular plane motion during dobutamine-atropine stress echocardiography:: The biphasic response in healthy subjects revisited
    Carstensen, S
    Host, U
    Atar, D
    Saunamäki, K
    Kelbæk, H
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2000, 13 (10) : 885 - 890
  • [5] Fractional flow reserve in patients with prior myocardial infarction
    De Bruyne, B
    Pijls, NHJ
    Bartunek, J
    Kulecki, K
    Bech, JW
    De Winter, H
    Van Crombrugge, P
    Heyndrickx, GR
    Wijns, W
    [J]. CIRCULATION, 2001, 104 (02) : 157 - 162
  • [6] Simultaneous coronary pressure and flow velocity measurements in humans - Feasibility, reproducibility, and hemodynamic dependence of coronary flow velocity reserve, hyperemic flow versus pressure slope index, and fractional flow reserve
    deBruyne, B
    Bartunek, J
    Sys, SU
    Pijls, NHJ
    Heyndrickx, GR
    Wijns, W
    [J]. CIRCULATION, 1996, 94 (08) : 1842 - 1849
  • [7] Regional myocardial systolic function during acute myocardial ischemia assessed by strain Doppler echocardiography
    Edvardsen, T
    Skulstad, H
    Aakhus, S
    Urheim, S
    Ihlen, H
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (03) : 726 - 730
  • [8] Non-contrast second harmonic imaging improves interobserver agreement and accuracy of dobutamine stress echocardiography in patients with impaired image quality
    Franke, A
    Hoffmann, R
    Kühl, HP
    Lepper, W
    Breithardt, OA
    Schormann, M
    Hanrath, P
    [J]. HEART, 2000, 83 (02) : 133 - 140
  • [9] Methodology, feasibility, safety and diagnostic accuracy of dobutamine stress echocardiography
    Geleijnse, ML
    Fioretti, PM
    Roelandt, JRTC
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (03) : 595 - 606
  • [10] Quantification of the myocardial response to low-dose Dobutamine using tissue Doppler echocardiographic measures of velocity and velocity gradient
    Gorcsan, J
    Deswal, A
    Mankad, S
    Mandarino, WA
    Mahler, CM
    Yamazaki, N
    Katz, WE
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (05) : 615 - 623