Regional reference values for some quantities measured with the ADVIA Centaur analyser.: A model of co-operation between the in vitro diagnostic industry and clinical laboratories

被引:18
作者
Ferré-Masferrer, M
Fuentes-Arderiu, X [1 ]
Gomà-Llongueras, M
Alumà-Trullàs, A
Aramendi-Ramos, M
Castaño-Vidriales, JL
Esteban-Salan, M
Graells-Ferrer, M
Jiménez-González, A
Jiménez-Lobo, C
López-Esparza, M
Parés-Pollán, L
Regulez-Uranga, M
Riesco-Prieto, M
Rodríguez-Camba, A
Vidal-Martínez, J
机构
[1] Ciutat Sanitaria & Univ Bellvitge, Servei Bioquim Clin, Lhospitalet De Llobregat, Catalonia, Spain
[2] Quim Farmaceut Bayer, Div Diagnost, Barcelona, Catalonia, Spain
[3] DAP Badalona & St Adria, Lab Clin Barcelones Nord, Badalona, Catalonia, Spain
[4] CEP Ambulatorio Hermanos Miralles, Lab Anal Clin, Madrid, Spain
[5] Hosp San Agustin, Lab Anal Clin, Linares, Andalusia, Spain
[6] Galdakaoko Ospitalea, Anal Klinicoaren Zerbitzua, Galdakao, Basque Country, Spain
[7] Hosp SVS Marina Baixa, Lab Anal Clin, Villajoiosa, Valencian Count, Spain
[8] Hosp Univ Guadalajara, Serv Anal Clin, Castilla La Mancha, Spain
[9] Hosp Severo Ochoa, Lab Bioquim Anal Clin, Madrid, Spain
[10] Ambulatorio Gen Solchaga, Lab Anal Clin, Navarra, Spain
[11] Hosp Nuestra Senora del Prado, Lab Anal Clin, Castilla Leon, Spain
[12] Hosp Cruces, Lab Bioquim, Baracaldo, Basque Country, Spain
[13] Hosp Univ Son Dureta, Lab Anal Clin, Ciutat De Mallorca, Balearic Island, Spain
[14] Complexo Hosp Cristal Pinor, Lab Anal Clin, Orense, Galicia, Spain
[15] Hosp Arnau Vilanova, Lab Anal Clin, Valencia, Spain
关键词
reference values; ADVIA Centaur Analyser;
D O I
10.1515/CCLM.2001.028
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
This work is a model of co-operation between the in vitro diagnostic industry and clinical laboratories for the production of reference values. Thirteen clinical laboratories having an ADVIA Centaur analyser and representing the majority of the geographical regions of Spain have shared the search for reference individuals and the production of reference values for thyrotropin, free thyroxine, free triiodothyronine, cobalamine and folate concentrations in serum. All the logistic work has been done in co-operation with the Spanish supplier of the ADVIA Centaur analyser. The reference limits produced in the virtual laboratory are derived from the blend of reference values obtained by each laboratory. The multicentre reference limits were estimated according to the recommendations of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC).
引用
收藏
页码:166 / 169
页数:4
相关论文
共 13 条
[1]  
BLAABJERG O, 1994, UPSALA J MED SCI, V99, P357
[2]  
Conover W, 1980, PRACTICAL NONPARAMET, P229
[3]  
DYBKAER R, 1987, CLIN CHIM ACTA, V170, pS33, DOI 10.1016/0009-8981(87)90152-5
[4]  
FerreMasferrer M, 1997, EUR J CLIN CHEM CLIN, V35, P715
[5]   ANALYTICAL GOALS FOR THE ACCEPTANCE OF COMMON REFERENCE INTERVALS FOR LABORATORIES THROUGHOUT A GEOGRAPHICAL AREA [J].
GOWANS, EMS ;
PETERSEN, PH ;
BLAABJERG, O ;
HORDER, M .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1988, 48 (08) :757-764
[6]  
PETITCLERC C, 1987, J CLIN CHEM CLIN BIO, V25, P639
[7]  
SOLBERG HE, 1988, J CLIN CHEM CLIN BIO, V26, P593
[8]  
SOLBERG HE, 1991, EUR J CLIN CHEM CLIN, V29, P531
[9]  
SOLBERG HE, 1987, J CLIN CHEM CLIN BIO, V25, P645
[10]  
SOLBERG HE, 1987, J CLIN CHEM CLIN BIO, V25, P337