Sequential injection system with higher dimensional electrochemical sensor signals Part 2.: Potentiometric e-tongue for the determination of alkaline ions

被引:47
作者
Cortina, M
Gutés, A
Alegret, S
del Valle, M [1 ]
机构
[1] Univ Autonoma Madrid, Dept Chem, Sensors & Biosensors Grp, Bellaterra 08193, Spain
[2] Escola Univ Politecn Medi Ambient, Barcelona 08100, Spain
关键词
sequential injection analysis; artificial neural networks; sensor array; electronic tongue;
D O I
10.1016/j.talanta.2005.01.023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An intelligent, automatic system based on an array of non-specific-response chemical sensors was developed. As a great amount of information is required for its correct modelling, we propose a system generating it itself. The sequential injection analysis (SIA) technique was chosen as it enables the processes of training, calibration, validation and operation to be automated simply. Detection was carried out using an array of potentiometric sensors based on PVC membranes of different selectivity. The diluted standard solutions needed for system learning and response modelling are automatically prepared from more concentrated standards. The electrodes used were characterised with respect to one and two analytes, by means of high-dimensionality calibrations, and the response surface of each was represented; this characterisation enabled an interference study of great practical utility. The combined response was modelled by means of artificial neural networks (ANNs), and thus it was possible to obtain an automated electronic tongue based on SIA. In order to identify the ANN which provided the best model of the electrode responses, some of the network's parameters were optimised and its usefulness in determining NH4+, K+ and Na+ ions in synthetic samples was then tested. Finally, it was used to determine these ions in commercial fertilisers, the obtained results being compared with reference methods. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1197 / 1206
页数:10
相关论文
共 29 条
[1]  
ALEGRET S, 2003, INTEGRATED ANAL SYST, pCH1
[2]   FLOW-THROUGH TUBULAR ION-SELECTIVE ELECTRODES RESPONSIVE TO ANIONIC SURFACTANTS FOR FLOW-INJECTION ANALYSIS [J].
ALONSO, J ;
BARO, J ;
BARTROLI, J ;
SANCHEZ, J ;
DELVALLE, M .
ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) :115-121
[3]  
[Anonymous], 1976, PURE APPL CHEM, V48, P127, DOI DOI 10.1351/PAC197648010127
[4]   Application of neural network calibrations to an halide ISE array [J].
Baret, M ;
Massart, DL ;
Fabry, P ;
Conesa, F ;
Eichner, C ;
Menardo, C .
TALANTA, 2000, 51 (05) :863-877
[5]   Halide ion-selective electrode array calibration [J].
Baret, M ;
Massart, DL ;
Fabry, P ;
Menardo, C ;
Conesa, F .
TALANTA, 1999, 50 (03) :541-558
[6]   SPARINGLY SELECTIVE ION-SELECTIVE ELECTRODE ARRAYS FOR MULTICOMPONENT ANALYSIS [J].
BEEBE, K ;
UERZ, D ;
SANDIFER, J ;
KOWALSKI, B .
ANALYTICAL CHEMISTRY, 1988, 60 (01) :66-71
[7]   PROCESSING OF SIGNALS FROM AN ION-SELECTIVE ELECTRODE ARRAY BY A NEURAL NETWORK [J].
BOS, M ;
BOS, A ;
VANDERLINDEN, WE .
ANALYTICA CHIMICA ACTA, 1990, 233 (01) :31-39
[8]   Flow techniques in water analysis [J].
Cerdà, V ;
Estela, JM ;
Forteza, R ;
Cladera, A ;
Becerra, E ;
Altimira, P ;
Sitjar, P .
TALANTA, 1999, 50 (04) :695-705
[9]   Portraits of gasses and liquids by arrays of nonspecific chemical sensors: trends and perspectives [J].
D'Amico, A ;
Di Natale, C ;
Paolesse, R .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 68 (1-3) :324-330
[10]   OPTIMIZATION OF POLYVINYL-CHLORIDE) MATRIX MEMBRANE ION-SELECTIVE ELECTRODES FOR AMMONIUM-IONS [J].
DAVIES, OG ;
MOODY, GJ ;
THOMAS, JDR .
ANALYST, 1988, 113 (03) :497-500