Syringomyelia hydrodynamics: An in vitro study based on in vivo measurements

被引:46
作者
Martin, BA [1 ]
Kalata, W
Loth, F
Royston, TJ
Oshinski, JN
机构
[1] Univ Illinois, Dept Mech & Ind Engn, Chicago, IL 60680 USA
[2] Emory Univ, Dept Radiol & Biomed Engn, Atlanta, GA 30322 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2005年 / 127卷 / 07期
关键词
D O I
10.1115/1.2073687
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A simplified in vitro model of the spinal canal, based on in vivo magnetic resonance imaging, was used to examine the hydrodynamics of the human spinal cord and subarachnoid space with syringomyelia. In vivo magnetic resonance imaging (MRI) measurements of subarachnoid (SAS) geometry and cerebrospinal fluid velocity were acquired in a patient with syringomyelia and used to aid in the in vitro model design and experiment. The in vitro model contained a fluid-filled coaxial elastic tube to represent a syrinx. A computer controlled pulsatile pump was used to subject the in vitro model to a CSF flow waveform representative of that measured in vivo. Fluid velocity was measured at three axial locations within the in vitro model using the same MRI scanner as the patient study. Pressure and syrinx wall motion measurements were conducted external to the MR scanner using the same model and flow input. Transducers measured unsteady pressure both in the SAS and intra-syrinx at four axial locations in the model. A laser Doppler vibrometer recorded the syrinx wall motion at 18 axial locations and three polar positions. Results indicated that the peak-to-peak amplitude of the SAS flow waveform in vivo was approximately tenfold that of the syrinx and in phase (SAS similar to 5.2 +/- 0.6 ml/s, syrinx similar to 0.5 +/- 0.3 ml/s). The in vitro flow waveform approximated the in vivo peak-to-peak magnitude (SAS similar to 4.6 +/- 0.2 ml/s, syrinx similar to 0.4 +/- 0.3 ml/s). Peak-to-peak in vitro pressure variation in both the SAS and syrinx was approximately 6 mm Hg. Syrinx pressure waveform lead the SAS pressure waveform by approximately 40 ms. Syrinx pressure was found to be less than the SAS for similar to 200 ms during the 860-ms flow cycle. Unsteady pulse wave velocity in the syrinx was computed to be a maximum of similar to 25 m/s. LDV measurements indicated that spinal cord wall motion was nonaxisymmetric with a maximum displacement of similar to 140 mu m, which is below the resolution limit of MRL Agreement between in vivo and in vitro MR measurements demonstrates that the hydrodynamics in the fluid filled coaxial elastic tube system are similar to those present in a single patient with syringomyelia. The presented in vitro study of spinal cord wall motion, and complex unsteady pressure and flow environment within the syrinx and SAS, provides insight into the complex biomechanical forces present in syringomyelia.
引用
收藏
页码:1110 / 1120
页数:11
相关论文
共 36 条
[1]  
AMABILI M, 2001, ASME, V68, P827
[2]  
BALL MJ, 1972, LANCET, V2, P799
[3]   Pressure wave propagation in fluid-filled co-axial elastic tubes part 1: Basic theory [J].
Berkouk, K ;
Carpenter, PW ;
Lucey, AD .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (06) :852-856
[4]  
Bertrand G, 1973, Clin Neurosurg, V20, P322
[5]   Effects of proteins, blood cells and glucose on the viscosity of cerebrospinal fluid [J].
Bloomfield, IG ;
Johnston, IH ;
Bilston, LE .
PEDIATRIC NEUROSURGERY, 1998, 28 (05) :246-251
[6]  
Bradbury MW, 1979, CONCEPT BLOOD BRAIN, P465
[7]   Pressure wave propagation in fluid-filled co-axial elastic tubes part 2: Mechanisms for the pathogenesis of syringomyelia [J].
Carpenter, PW ;
Berkouk, K ;
Lucey, AD .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (06) :857-863
[8]   Wave propagation in a system of coaxial tubes filled with incompressible media: A model of pulse transmission in the intracranial arteries [J].
Cirovic, S ;
Walsh, C ;
Fraser, WD .
JOURNAL OF FLUIDS AND STRUCTURES, 2002, 16 (08) :1029-1049
[9]  
DAVSON H, 1967, PHYSL CEREBROSPINAL, V7, P445
[10]   A STUDY OF CEREBROSPINAL FLUID PULSE WAVE [J].
DUNBAR, HS ;
GUTHRIE, TC ;
KARPELL, B .
ARCHIVES OF NEUROLOGY, 1966, 14 (06) :624-&