High-resolution gas chromatography retention data as a basis for estimation of the octanol-water distribution coefficients (Kow) of PCB:: the effect of experimental conditions

被引:14
作者
Ballschmiter, K [1 ]
Klingler, D [1 ]
Ellinger, S [1 ]
Hackenberg, R [1 ]
机构
[1] Univ Ulm, Dept Analyt & Environm Chem, D-89069 Ulm, Germany
关键词
Kow values; relative retention time; total surface area; polychlorinated biphenyls;
D O I
10.1007/s00216-005-3307-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The semi-experimental approach to approximating physicochemical data relevant to environmental distribution (vapor pressure and gas-octanol distribution) by correlation with gas chromatography (GC) retention data has been extended to the determination of Kow values. We estimated Kow values > 10(4) for poly-chlorinated biphenyls (PCB), which are often derived by liquid chromatography, by correlation with gas chromatographic retention data. Selecting a set of reference compounds with known Kow values for relative retention time (RRT) correlation enables easy and accurate semi-empirical calculation of further Kow values for a given group of congeners. The RRT/log Kow correlation is validated in this paper with regard to the following gas chromatographic conditions: (1) isothermal versus temperature-programmed elution, (2) the possible effect of the polarity of the stationary phase, and (3) the effect of the format of the standardized GC retention data. The advantages of our Kow(GC) method can be summarized as follows: complex mixtures can be analyzed, only amounts in the nanogram-range or less are required, Kow values of isomers can be determined and the exact structure of compounds need not be known. Normalized GC retention data of persistent organic pollutants are readily available. The quality of the Kow values obtained by the GC method compares well with that for other Kow estimation methods. It depends mainly on the accuracy of the Kow data of the structurally correlated compounds used as standards for the correlation cohort. The Kow(GC) data for all 209 PCB congeners are given.
引用
收藏
页码:1859 / 1870
页数:12
相关论文
共 37 条
[1]   HYDROGEN-BONDING .35. RELATIONSHIP BETWEEN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY CAPACITY FACTORS AND WATER-OCTANOL PARTITION-COEFFICIENTS [J].
ABRAHAM, MH ;
CHADHA, HS ;
LEO, AJ .
JOURNAL OF CHROMATOGRAPHY A, 1994, 685 (02) :203-211
[2]   HYDROGEN-BONDING .32. AN ANALYSIS OF WATER-OCTANOL AND WATER-ALKANE PARTITIONING AND THE DELTA-LOG-P PARAMETER OF SEILER [J].
ABRAHAM, MH ;
CHADHA, HS ;
WHITING, GS ;
MITCHELL, RC .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1994, 83 (08) :1085-1100
[3]  
BALLSCHMITER K, 1992, J HIGH RES CHROMATOG, V15, P260
[4]   ESTIMATION OF VAPOR-PRESSURES FOR NONPOLAR ORGANIC-COMPOUNDS BY CAPILLARY GAS-CHROMATOGRAPHY [J].
BIDLEMAN, TF .
ANALYTICAL CHEMISTRY, 1984, 56 (13) :2490-2496
[5]   REVERSED PHASE LIQUID-CHROMATOGRAPHY OF PCBS AS A BASIS FOR THE CALCULATION OF WATER SOLUBILITY AND LOG KOW FOR POLYCHLOROBIPHENYLS [J].
BRODSKY, J ;
BALLSCHMITER, K .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 331 (3-4) :295-301
[6]   New QSAR methods applied to structure-activity mapping and combinatorial chemistry [J].
Burden, FR ;
Winkler, DA .
JOURNAL OF CHEMICAL INFORMATION AND COMPUTER SCIENCES, 1999, 39 (02) :236-242
[7]  
COLLANDER R, 1947, ACTA PHYSIOL SCAND, V13, P363
[8]   THE DISTRIBUTION OF ORGANIC COMPOUNDS BETWEEN ISO-BUTANOL AND WATER [J].
COLLANDER, R .
ACTA CHEMICA SCANDINAVICA, 1950, 4 (07) :1085-1098
[9]   Comment on "High-resolution gas chromatography retention data as basis for the estimation of Kow values using PCB congeners as secondary standards" [J].
Fenner, K ;
Roth, C ;
Goss, KU ;
Schwarzenbach, RP .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2004, 38 (07) :2286-2287
[10]   RELATIONSHIP BETWEEN EXPERIMENTALLY DETERMINED VAPOR-PRESSURES AND RETENTION TIMES OF PCB ON A 50-PERCENT N-OCTYL-METHYLPOLYSILOXANE STATIONARY PHASE [J].
FISCHER, R ;
BALLSCHMITER, K .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 333 (07) :731-732