Use of a wearable defibrillator in terminating tachyarrhythmias in patients at high risk for sudden death: Results of WEARIT/BIROAD

被引:156
作者
Feldman, AM
Klein, H
Tchou, P
Murali, S
Hall, WJ
Mancini, D
Boehmer, J
Harvey, M
Hellman, MS
Szymkiewicz, SJ
Moss, AJ
机构
[1] Jefferson Med Coll, Dept Med, Philadelphia, PA 19107 USA
[2] Otto Von Guericke Univ, Magdeburg, Germany
[3] Cleveland Clin Fdn, Dept Cardiol, Cleveland, OH 44195 USA
[4] Univ Pittsburgh, Med Ctr, Cardiovasc Inst, Pittsburgh, PA USA
[5] Univ Rochester, Rochester, NY USA
[6] Columbia Presbyterian Med Ctr, Div Cardiol, New York, NY USA
[7] Milton S Hershey Med Ctr, Hershey, PA USA
[8] Oklahoma Fdn Cardiovasc Res, Oklahoma City, OK USA
[9] LIFECOR Inc, Pittsburgh, PA USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2004年 / 27卷 / 01期
关键词
ventricular arrhythmias; defibrillation; heart failure; sudden death;
D O I
10.1111/j.1540-8159.2004.00378.x
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
The automatic ICD improves survival in patients with a history of sudden cardiac arrest. However, some patients do not meet the guidelines for ICD implantation or are unable to receive on implantable device. This study tested the hypothesis that these patients could benefit from a wearable cardioverter defibrillator. Patients with symptomatic heart failure and an ejection fraction of <0.30 (WEARIT Study) or patients having complications associated with high risk for sudden death after a myocardial infarction or bypass surgery not receiving an ICD for up to 4 months (BIROAD Study) were enrolled into two studies. After a total of 289 patients had been enrolled in the trial (177 in WEARIT and 112 in BIROAD), prespecified safety and effectiveness guidelines had been met. Six (75%) of eight defibrillation attempts were successful. Six inappropriate shock episodes occurred during 901 months of patient use (0.67% unnecessary shocks per month of use). Twelve deaths occurred during the study 6 sudden deaths: 5 not wearing and 1 incorrectly wearing the device). Most patients tolerated the device although 68 patients quit due to comfort issues or adverse reactions. The results of the present study suggest that a wearable defibrillator is beneficial in detecting and effectively treating ventricular tachyarrhythmias in patients at high risk for sudden death who are not clear candidates for an ICD and may be useful as a bridge to transplantation or ICD in some patients.
引用
收藏
页码:4 / 9
页数:6
相关论文
共 21 条
[1]
AKHTAR M, 1992, CIRCULATION, V85, P1
[2]
Clinical efficacy of the wearable cardioverter-defibrillator in acutely terminating episodes of ventricular fibrillation [J].
Auricchio, A ;
Klein, H ;
Geller, CJ ;
Reek, S ;
Heilamn, MS ;
Szymkiewicz, SJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (10) :1253-+
[3]
USE OF THE AUTOMATIC EXTERNAL DEFIBRILLATOR IN HOMES OF SURVIVORS OF OUT-OF-HOSPITAL VENTRICULAR-FIBRILLATION [J].
EISENBERG, MS ;
MOORE, J ;
CUMMINS, RO ;
ANDRESEN, E ;
LITWIN, PE ;
HALLSTROM, AP ;
HEARNE, T .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (07) :443-446
[4]
Comparison of sudden and nonsudden coronary deaths in the United States [J].
Escobedo, LG ;
Zack, MM .
CIRCULATION, 1996, 93 (11) :2033-2036
[5]
SUDDEN CORONARY DEATH IN THE UNITED-STATES - 1980-1985 [J].
GILLUM, RF .
CIRCULATION, 1989, 79 (04) :756-765
[6]
Gregoratos G, 1998, J AM COLL CARDIOL, V31, P1175
[7]
Complications of third-generation implantable cardioverter defibrillator therapy [J].
Grimm, W ;
Menz, V ;
Hoffmann, J ;
Timmann, U ;
Funck, R ;
Moosdorf, R ;
Maisch, B .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (01) :206-211
[8]
ELECTROCARDIOGRAPHICALLY DOCUMENTED UNNECESSARY, SPONTANEOUS SHOCKS IN 241 PATIENTS WITH IMPLANTABLE CARDIOVERTER DEFIBRILLATORS [J].
GRIMM, W ;
FLORES, BF ;
MARCHLINSKI, FE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (11) :1667-1673
[9]
Survival after cardiac arrest outside hospital in Sweden [J].
Holmberg, M ;
Holmberg, S ;
Herlitz, J ;
Gardelov, B .
RESUSCITATION, 1998, 36 (01) :29-36
[10]
ADVANCE PREDICTION OF TRANS-THORACIC IMPEDANCE IN HUMAN DEFIBRILLATION AND CARDIOVERSION - IMPORTANCE OF IMPEDANCE IN DETERMINING THE SUCCESS OF LOW-ENERGY SHOCKS [J].
KERBER, RE ;
KOUBA, C ;
MARTINS, J ;
KELLY, K ;
LOW, R ;
HOYT, R ;
FERGUSON, D ;
BAILEY, L ;
BENNETT, P ;
CHARBONNIER, F .
CIRCULATION, 1984, 70 (02) :303-308