Objective. To determine whether replacement of the nucleus with a synthetic material would prevent the effects of nucleus removal. Design. Laboratory experiments on excised tissues and a finite element model. Background. Removal of the nucleus from the intervertebral disc causes the inner margins of the annulus to bulge inwards, instead of outwards, during compression. This may cause the annulus to degenerate further. Methods. Video recordings of sheep discs, sectioned in the sagittal plane, were obtained during compression in a materials testing machine, the cut face of the disc was sealed with a Perspex window. Experiments were repeated with the nucleus removed and then replaced by a synthetic implant. A finite element model of an intact disc was also used to investigate the effect of nucleus replacement. Results. When the nucleus of sectioned discs was replaced with the polymer materials, the inward bulging of the annulus was not observed. The predictions from the finite element model of the intact disc were consistent with this result. Conclusions. Replacement of the nucleus with a synthetic material can prevent the changes in annulus behaviour that result from removal of the nucleus.
引用
收藏
页码:560 / 565
页数:6
相关论文
共 24 条
[1]
BAO QB, 1998, Patent No. 5534028
[2]
BLAND M, 1995, INTRO MED STAT, P134
[3]
CHANGE OF DISK HEIGHT, RADIAL DISK BULGE, AND INTRADISCAL PRESSURE FROM DISCECTOMY - AN INVITRO INVESTIGATION ON HUMAN LUMBAR DISKS [J].
BRINCKMANN, P ;
GROOTENBOER, H .
SPINE, 1991, 16 (06) :641-646
[4]
Migration of the nucleus pulposus within the intervertebral disc during flexion and extension of the spine [J].
Fennell, AJ ;
Jones, AP ;
Hukins, DWL .
SPINE, 1996, 21 (23) :2753-2757
[5]
The Cochrane review of surgery for lumbar disc prolapse and degenerative lumbar spondylosis [J].
Gibson, JNA ;
Grant, IC ;
Waddell, G .
SPINE, 1999, 24 (17) :1820-1832
[6]
INTERLAMINAR SHEAR STRESSES AND LAMINAE SEPARATION IN A DISC - FINITE-ELEMENT ANALYSIS OF THE L3-L4 MOTION SEGMENT SUBJECTED TO AXIAL COMPRESSIVE LOADS [J].
GOEL, VK ;
MONROE, BT ;
GILBERTSON, LG ;
BRINCKMANN, P ;
NAT, R .
SPINE, 1995, 20 (06) :689-698
[7]
Viscoelastic properties of nucleus pulposus [J].
Leahy, JC ;
Hukins, DWL .
JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 1997, 9 (01) :47-48
[8]
STRUCTURAL COMPONENTS OF INTERVERTEBRAL-DISK - STUDY OF THEIR CONTRIBUTIONS TO ABILITY OF DISK TO WITHSTAND COMPRESSIVE FORCES [J].
MARKOLF, KL ;
MORRIS, JM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1974, A 56 (04) :675-687
[9]
The effect of partial removal of the nucleus pulposus from the intervertebral disc on the response of the human annulus fibrosus to compression [J].
Meakin, JR ;
Redpath, TW ;
Hukins, DWL .
CLINICAL BIOMECHANICS, 2001, 16 (02) :121-128
[10]
Replacing the nucleus pulposus of the intervertebral disk: prediction of suitable properties of a replacement material using finite element analysis [J].
Meakin, JR ;
Hukins, DWL .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2001, 12 (03) :207-213