Endothelial cell loss after Descemet's stripping endothelial keratoplasty in a large prospective series

被引:186
作者
Terry, Mark A. [1 ,2 ]
Chen, Edwin S. [1 ]
Shamie, Neda [1 ]
Hoar, Karen L. [1 ]
Friend, Daniel J. [2 ]
机构
[1] Devers Eye Inst, Corneal Serv, Portland, OR 97210 USA
[2] Lions Vis Res Lab Oregon, Portland, OR USA
关键词
D O I
10.1016/j.ophtha.2007.10.035
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To report the donor endothelial cell loss in the first year after Descemet's stripping endothelial keratoplasty (DSEK) for the treatment of endothelial dysfunction. Design: Prospective noncomparative interventional case series. Participants: Eighty eyes of 78 patients with corneal edema. Methods: Eighty eyes with endothelial failure were entered into a prospective study of endothelial keratoplasty (EK). The donor central endothelial cell density (ECD) was recorded postoperatively at 6 months (n = 80) and 12 months (n = 80) and then compared with the preoperative eye bank measurements. The subsets of eyes with the donor prepared manually (DSEK; n = 19) and the donor prepared with a microkeratome (Descemet's stripping automated EK [DSAEK]; n = 61) were also evaluated and compared. Main Outcome Measures: Preoperative and postoperative central ECDs were prospectively evaluated and the cell loss calculated for each postoperative time point. Results: The average and standard deviation ECD at 6 months was 1908 +/- 354 cells/mm(2), representing a mean cell loss from preoperative donor cell measurements of 34 +/- 12%. At 12 months, ECD was 1856 +/- 371 cellS/mm(2) (35 +/- 13% cell loss). The 1% additional cell loss from 6 to 12 months was not significant (P = 0.233). In the subset of DSEK eyes (n = 19), the cell loss from preoperatively to 6 months was 34%, and at 12 months it was 39%. In the subset of DSAEK eyes (n = 61), the cell loss from preoperatively to 6 months was 34%, and at 12 months it was 34%. There was no statistical difference between the cell loss from DSEK and that from DSAEK at 6 months (P = 0.884) or at 12 months (P = 0.224). Conclusions: Descemet's stripping EK using our surgical technique has a mean donor endothelial cell loss of 34% at the 6-month postoperative examination, and this average cell loss remains relatively stable up to at least 1 year. We found no difference in cell loss between the DSEK and DSAEK techniques over this 1-year postoperative period.
引用
收藏
页码:488 / 496
页数:9
相关论文
共 34 条
[1]   Comparison of Chen Medium and Optisol-GS for human corneal preservation at 4°C -: Results of transplantation [J].
Bourne, WM ;
Nelson, LR ;
Maguire, LJ ;
Baratz, KH ;
Hodge, DO .
CORNEA, 2001, 20 (07) :683-686
[2]   Cellular changes in transplanted human corneas [J].
Bourne, WM .
CORNEA, 2001, 20 (06) :560-569
[3]   Initial results of small incision deep lamellar endothelial keratoplasty (DLEK) [J].
Fogla, R ;
Padmanabhan, P .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (02) :346-351
[4]   Prospective, randomized clinical evaluation of optisol vs organ culture corneal storage media [J].
Frueh, BE ;
Böhnke, M .
ARCHIVES OF OPHTHALMOLOGY, 2000, 118 (06) :757-760
[5]   Descemet-stripping automated endothelial keratoplasty [J].
Gorovoy, Mark S. .
CORNEA, 2006, 25 (08) :886-889
[6]   Simultaneous versus sequential penetrating keratoplasty and cataract surgery [J].
Hayashi, Ken ;
Hayashi, Hideyuki .
CORNEA, 2006, 25 (09) :1020-1025
[7]   Ten-year postoperative results of penetrating keratoplasty [J].
Ing, JJ ;
Ing, HH ;
Nelson, LR ;
Hodge, DO ;
Bourne, WM .
OPHTHALMOLOGY, 1998, 105 (10) :1855-1865
[8]   Visual acuity, refractive error, and endothelial cell density six months after descemet stripping and automated endothelial keratoplasty (DSAEK) [J].
Koenig, Steven B. ;
Covert, Douglas J. ;
Dupps, William J., Jr. ;
Meisler, David M. .
CORNEA, 2007, 26 (06) :670-674
[9]   Corneal endothelial cell loss after nonmechanical penetrating keratoplasty depends on diagnosis: a regression analysis [J].
Langenbucher, A ;
Seitz, B ;
Nguyen, NX ;
Naumann, GOH .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2002, 240 (05) :387-392
[10]   An evaluation of image quality and accuracy of eye bank measurement of donor cornea endothelial cell density in the Specular Microscopy Ancillary Study [J].
Lass, JH ;
Gal, RL ;
Ruedy, KJ ;
Benetz, BA ;
Beck, RW ;
Baratz, KH ;
Holland, EJ ;
Kalajian, A ;
Kollman, C ;
Manning, FJ ;
Mannis, MJ ;
McCoy, K ;
Montoya, M ;
Stulting, RD ;
Xing, DY ;
Densley, D ;
Moke, PS ;
Powe, A ;
Edwards, S ;
Karpinecz, L ;
Rice, C ;
Redford, M ;
Cotch, MF .
OPHTHALMOLOGY, 2005, 112 (03) :431-440