Changes in the crystallinity and mechanical properties of poly(l-lactic acid)/poly(butylene succinate-co-l-lactate) blend with annealing process

被引:22
作者
Chou, P. M. [1 ]
Mariatti, M. [1 ]
Zulkifli, A. [1 ]
Todo, M. [2 ]
机构
[1] Univ Sains Malaysia, Sch Mat & Mineral Resources Engn, George Town 14300, Malaysia
[2] Kyushu Univ, Appl Mech Res Inst, Fukuoka 8120003, Japan
关键词
Poly(L-lactic acid) (PLLA); Poly(butylene succinate-co-L-lactate) (PBSL); Annealing; Crystallization behavior; CRYSTALLIZATION BEHAVIOR; THERMAL-PROPERTIES; POLY(LACTIC ACID); MORPHOLOGY; MISCIBILITY; COPOLYMERS; PLA;
D O I
10.1007/s00289-011-0456-5
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Biodegradable polymer blends of poly(l-lactic acid) (PLLA) and poly(butylene succinate-co-l-lactate) (PBSL) at various blending ratios are prepared. The blending of PLLA with PBSL results in an increase in the ductility and thermal stability of the blend. However, flexural strength and modulus, as well as loss modulus, decrease with an increase in PBSL content. Annealing is employed to increase blend crystallinity and subsequently improve the mechanical properties of the PLLA/PBSL blend. The influences of annealing time on the crystal modification, thermal properties, and mechanical properties of the PLLA/PBSL blend are investigated by X-ray diffraction (XRD), differential scanning calorimetry (DSC), and three-point bending test, respectively. Crystalline peaks are found in the XRD patterns of all annealed samples. DSC analysis reveals that the degree of crystallinity is enhanced with an increase in annealing time. The flexural modulus also increases with annealing time due to the change in crystalline phases. However, longer periods of annealing, especially over 20 h, result in thermal degradation and subsequently reduce the modulus value of the PLLA/PBSL blend.
引用
收藏
页码:815 / 830
页数:16
相关论文
共 32 条
[1]   Poly(D,L-lactic acid)/poly (ε-caprolactone) blend membranes:: preparation and morphological characterisation [J].
Aslan, S ;
Calandrelli, L ;
Laurienzo, P ;
Malinconico, M ;
Migliaresi, C .
JOURNAL OF MATERIALS SCIENCE, 2000, 35 (07) :1615-1622
[2]  
*ASTM, 2005, ANN BOOK ASTM STAND, P149
[3]  
Bhatia A, 2007, KOREA-AUST RHEOL J, V19, P125
[4]   DSC study of biodegradable poly(lactic acid) and poly(hydroxy ester ether) blends [J].
Cao, X ;
Mohamed, A ;
Gordon, SH ;
Willett, JL ;
Sessa, DJ .
THERMOCHIMICA ACTA, 2003, 406 (1-2) :115-127
[5]  
Drumright RE, 2000, ADV MATER, V12, P1841, DOI 10.1002/1521-4095(200012)12:23<1841::AID-ADMA1841>3.0.CO
[6]  
2-E
[7]   Correlation between degree of crystallinity, morphology, glass temperature, mechanical properties and biodegradation of poly (3-hydroxyalkanoate) PHAs and their blends [J].
El-Hadi, A ;
Schnabel, R ;
Straube, E ;
Müller, G ;
Henning, S .
POLYMER TESTING, 2002, 21 (06) :665-674
[8]   INVESTIGATION OF STRUCTURE OF SOLUTION GROWN CRYSTALS OF LACTIDE COPOLYMERS BY MEANS OF CHEMICAL-REACTIONS [J].
FISCHER, EW ;
STERZEL, HJ ;
WEGNER, G .
KOLLOID-ZEITSCHRIFT AND ZEITSCHRIFT FUR POLYMERE, 1973, 251 (11) :980-990
[9]   A literature review of poly(lactic acid) [J].
Garlotta, D .
JOURNAL OF POLYMERS AND THE ENVIRONMENT, 2001, 9 (02) :63-84
[10]  
Hatakeyama T., 1994, THERMAL ANAL FUNDAME