摘要
The performance of an integrative passive sampler that consists of a C18 Empore disk sorbent receiving phase fitted with low density polyethylene membrane was optimised for the measurement of time-weighted average concentrations of hydrophobic micropollutants in water. A substantial improvement of sampling characteristics including the rate of sampling and the sampling precision was achieved by decreasing the internal sampler resistance to mass transfer of hydrophobic organic chemicals. This was achieved by adding a small volume of n-octanol, a solvent with high permeability (solubility x diffusivity) for target analytes, to the interstial space between the receiving sorbent phase and the polyethylene diffusion-limiting membrane.
引用
收藏
页码:612 / 620
页数:9
相关论文
共 33 条
[1]   Calibrating the uptake kinetics of semipermeable membrane devices using exposure standards [J].
Booij, K ;
Sleiderink, HM ;
Smedes, F .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 1998, 17 (07) :1236-1245
[2]   Estimating dissolved organic carbon partition coefficients for nonionic organic chemicals [J].
Burkhard, LP .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (22) :4663-4668
[3]   INVESTIGATION OF THE KINETIC-PROPERTIES OF PARTICLE-LOADED MEMBRANES FOR SOLID-PHASE EXTRACTION BY FORCED FLOW PLANAR CHROMATOGRAPHY [J].
FERNANDO, WPN ;
LARRIVEE, ML ;
POOLE, CF .
ANALYTICAL CHEMISTRY, 1993, 65 (05) :588-595
[4]   CORRELATION AND PREDICTION OF MASS-TRANSPORT ACROSS MEMBRANES .1. INFLUENCE OF ALKYL CHAIN-LENGTH ON FLUX-DETERMINING PROPERTIES OF BARRIER AND DIFFUSANT [J].
FLYNN, GL ;
YALKOWSKY, SH .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1972, 61 (06) :838-+
[5]  
HOFMANS HE, 1998, THESIS U UTRECHT DEN
[6]   Development of the permeability/performance reference compound approach for in situ calibration of semipermeable membrane devices [J].
Huckins, JN ;
Petty, JD ;
Lebo, JA ;
Almeida, FV ;
Booij, K ;
Alvarez, DA ;
Clark, RC ;
Mogensen, BB .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2002, 36 (01) :85-91
[7]   Determination of uptake kinetics (Sampling rates) by lipid-containing semipermeable membrane devices (SPMDs) for polycyclic aromatic hydrocarbons (PAHs) in water [J].
Huckins, JN ;
Petty, JD ;
Orazio, CE ;
Lebo, JA ;
Clark, RC ;
Gibson, VL ;
Gala, WR ;
Echols, KR .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (21) :3918-3923
[8]  
HUCKINS JN, 1990, J ASSOC OFF ANA CHEM, V73, P290
[9]   LIPID-CONTAINING SEMIPERMEABLE-MEMBRANE DEVICES FOR MONITORING ORGANIC CONTAMINANTS IN WATER [J].
HUCKINS, JN ;
MANUWEERA, GK ;
PETTY, JD ;
MACKAY, D ;
LEBO, JA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1993, 27 (12) :2489-2496
[10]  
HUCKINS JN, 2000, API PUBLICATION, V4690