Medical applications of synchrotron radiation at the SYRMEP beamline of ELETTRA

被引:90
作者
Abrami, A
Arfelli, F
Barroso, RC
Bergamaschi, A
Billé, F
Bregant, P
Brizzi, F
Casarin, K
Castelli, E
Chenda, V
Palma, LD
Dreossi, D
Fava, A
Longo, R
Mancini, L
Menk, RH
Montanari, F
Olivo, A
Pani, S
Pillon, A
Quai, E
Kaiser, SR
Rigon, L
Rokvic, T
Tonutti, M
Tromba, G
Vaseotto, A
Venanzi, C
Zanconati, F
Zanetti, A
Zanini, F
机构
[1] Univ Trieste, Dipartmento Fis, I-34127 Trieste, Italy
[2] Sincrotrone Trieste SCpA, I-34012 Trieste, Italy
[3] Ist Nazl Fis Nucl, Sez Trieste, I-34127 Trieste, Italy
[4] Univ Estado Rio De Janeiro, Inst Fis, BR-900 Rio De Janeiro, RJ, Brazil
[5] Azienda Osped Univ Osped Riuniti Trieste, I-34129 Trieste, Italy
[6] Univ Trieste, Dipartimento Univ Clin Sci Clin Morfol & Tecnol, Osped Cattinara, I-34139 Trieste, Italy
[7] Univ Belgrade, Fac Phys, Belgrade 11001, Serbia Monteneg
关键词
synchrotron radiation; mammography; tomography; phase contrast; diffraction enhanced imaging;
D O I
10.1016/j.nima.2005.03.093
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The main purpose of the SYRMEP (SYnchtotron Radiation for MEdical Physics) research team is the investigation and development of innovative techniques for medical imaging. A dedicated beamline has been built at ELETTRA to evaluate the effectiveness of synchrotron-based techniques in medical radiology with particular interest to mammography, and more in general, to the imaging of biological and biomedical samples, either in planar or tomographic set-ups. Taking advantage of the high intensity and high spatial coherence of Synchrotron Radiation (SR), phase sensitive techniques such as Phase Contrast (PhC) and Diffraction Enhanced Imaging (DEI) can be applied. After successful studies carried out on test objects and in vitro samples, the research in mammography is aiming at in vivo clinical trials. For this purpose, the layout of the SYRMEP beamline has been substantially modified and the safety system has been completely redesigned to guarantee the compliance with current radiation protection guidelines. In the present paper, the main characteristics of the beamline and an overview of the results obtained in different contexts of biomedical imaging are presented. Moreover, the status of the project for clinical mammography is outlined. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:221 / 227
页数:7
相关论文
共 28 条
[1]   Low-dose phase contrast x-ray medical imaging [J].
Arfelli, F ;
Assante, M ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
Dalla Palma, L ;
Di Michiel, M ;
Longo, R ;
Olivo, A ;
Pani, S ;
Pontoni, D ;
Poropat, P ;
Prest, M ;
Rashevsky, A ;
Tromba, G ;
Vacchi, A ;
Vallazza, E ;
Zanconati, F .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (10) :2845-2852
[2]   Mammography of a phantom and breast tissue with synchrotron radiation and a linear-array silicon detector [J].
Arfelli, F ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
Dalla Palma, L ;
Di Michiel, M ;
Longo, R ;
Olivo, A ;
Pani, S ;
Pontoni, D ;
Poropat, P ;
Prest, M ;
Rashevsky, A ;
Tromba, G ;
Vacchi, A .
RADIOLOGY, 1998, 208 (03) :709-715
[3]   Mammography with synchrotron radiation: Phase-detection techniques [J].
Arfelli, F ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
Dalla Palma, L ;
Di Michiel, M ;
Fabrizioli, M ;
Longo, R ;
Menk, RH ;
Olivo, A ;
Pani, S ;
Pontoni, D ;
Poropat, P ;
Prest, M ;
Rashevsky, A ;
Ratti, M ;
Rigon, L ;
Tromba, G ;
Vacchi, A ;
Vallazza, E ;
Zanconati, F .
RADIOLOGY, 2000, 215 (01) :286-293
[4]   A multilayer edge-on silicon microstrip single photon counting detector for digital mammography [J].
Arfelli, F ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
Fabrizioli, M ;
Longo, R ;
Olivo, A ;
Pani, S ;
Pontoni, D ;
Poropat, P ;
Prest, M ;
Rashevsky, A ;
Rigon, L ;
Tromba, G ;
Vacchi, A ;
Vallazza, E .
NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 1999, 78 :592-597
[5]  
Arfelli F, 1997, PHYS MEDICA, V13, P7
[6]   High-speed single photon counting read out electronics for a digital detection system for clinical synchrotron radiation mammography [J].
Bergamaschi, A ;
Arfelli, F ;
Dreossi, D ;
Longo, R ;
Olivo, A ;
Pani, S ;
Rigon, L ;
Vallazza, E ;
Venanzi, C ;
Castelli, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 518 (1-2) :415-417
[7]   FIXED-EXIT DOUBLE-CRYSTAL MONOCHROMATOR FOR THE DIFFRACTION BEAMLINE AT ELETTRA - A NEW CONCEPT FOR CRYSTAL MOVEMENTS [J].
BERNSTORFF, S ;
BUSETTO, E ;
SAVOIA, A ;
COLAPIETRO, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :2065-2068
[8]  
BETTUZZI M, 2004, P IEEE NUCL SCI S ME
[9]   Holotomography: Quantitative phase tomography with micrometer resolution using hard synchrotron radiation x rays [J].
Cloetens, P ;
Ludwig, W ;
Baruchel, J ;
Van Dyck, D ;
Van Landuyt, J ;
Guigay, JP ;
Schlenker, M .
APPLIED PHYSICS LETTERS, 1999, 75 (19) :2912-2914
[10]   Observation of microstructure and damage in materials by phase sensitive radiography and tomography [J].
Cloetens, P ;
PateyronSalome, M ;
Buffiere, JY ;
Peix, G ;
Baruchel, J ;
Peyrin, F ;
Schlenker, M .
JOURNAL OF APPLIED PHYSICS, 1997, 81 (09) :5878-5886