Evaluating the role for the optical density in the diagnosis of heparin-induced thrombocytopenia following cardiac surgery

被引:4
作者
Chan, Chee M. [1 ]
Corso, Paul J. [2 ]
Sun, Xiumei [2 ]
Hill, Peter C. [2 ]
Shorr, Andrew F. [1 ]
机构
[1] Washington Hosp Ctr, Div Pulm & Crit Care Med, Washington, DC 20010 USA
[2] Washington Hosp Ctr, Div Cardiothorac Surg, Washington, DC 20010 USA
关键词
Heparin; optical density; screening; thrombocytopenia; VALUES; IMMUNOASSAY; THROMBOSIS;
D O I
10.1160/TH11-04-0273
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The poor accuracy of the enzyme immune assay (EIA) contributes to the diagnostic challenge of heparin-induced thrombocytopenia (HIT) following cardiac surgery. We sought to determine if adjusting the threshold optical density (OD) defining a positive EIA improves the test's accuracy in subjects with an OD>0.40. We retrospectively analysed the results from both EIA and confirmatory serotonin release assays (SRAs) in cardiac surgery patients with EIA OD of >0.4. Employing the SRA as the standard, we compared the area under the receiver-operating characteristic (AUROC) curves of various OD measurements for identifying HIT. We examined baseline clinical variables associated with a positive SRA in the setting of a positive HIT EIA (OD >0.4). We then used logistic regression to identify baseline clinical variables independently associated with a positive SRA given a positive EIA. The cohort included 99 subjects with positive EIAs and 35% had positive SRAs. An OD>0.40 had moderate utility as a screening test for a positive SRA (AUROC: 0.68; 95% CI: 0.55-0.80). Increasing the OD threshold did not improve the HIT EIA's screening utility. Clinical variables independently associated with a positive SRA if the EIA were positive included female gender, absence of diabetes, and use of cardiopulmonary bypass. A relatively modest elevation in the OD measurement, when it is already known to be greater than 0.4, does not reliably exclude the potential for a positive SRA in this setting.
引用
收藏
页码:934 / 938
页数:5
相关论文
共 15 条
[1]   Performance characteristics of two commercially available IgG-specific immunoassays in the assessment of heparin-induced thrombocytopenia (HIT) [J].
Bakchoul, Tamam ;
Giptner, Astrid ;
Bein, Gregor ;
Santoso, Sentot ;
Sachs, Ulrich J. H. .
THROMBOSIS RESEARCH, 2011, 127 (04) :345-348
[2]   Heparin-induced thrombocytopenia [J].
Chong, BH .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2003, 1 (07) :1471-1478
[3]  
Cuker Adam, 2009, Hematology Am Soc Hematol Educ Program, P250, DOI 10.1182/asheducation-2009.1.250
[4]   A critical evaluation of assays for detecting antibodies to the heparin-PF4 complex [J].
Francis, JL .
SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2004, 30 (03) :359-368
[5]   Usefulness of optical density values from neparin-platelet factor 4 antibody testing and probability scoring models to diagnose heparin-induced thrombocytopenia [J].
Janatpour, Kim A. ;
Gosselin, Robert C. ;
Dager, William E. ;
Lee, Andrew ;
T Owings, John ;
Zhou, Jufen ;
Wun, Ted .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2007, 127 (03) :429-433
[6]   Utility of ELISA Optical Density Values and Clinical Scores for the Diagnosis of and Thrombosis Prediction in Heparin-induced Thrombocytopenia [J].
Kim, Seon Young ;
Kim, Hyun Kyung ;
Han, Kyou Sup ;
Kim, Inho ;
Yoon, Sung-Soo ;
Park, Seonyang ;
Kim, Byoung Kook .
KOREAN JOURNAL OF LABORATORY MEDICINE, 2011, 31 (01) :1-8
[7]   Prospective evaluation of the '4Ts' score and particle gel immunoassay specific to heparin/PF4 for the diagnosis of heparin-induced thrombocytopenia [J].
Pouplard, C. ;
Gueret, P. ;
Fouassier, M. ;
Ternisien, C. ;
Trossaert, M. ;
Regina, S. ;
Gruel, Y. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2007, 5 (07) :1373-1379
[8]   Effectiveness of a new immuno-assay for the diagnosis of heparin-induced thrombocytopenia and improved specificity when detecting IgG antibodies [J].
Pouplard, Claire ;
Leroux, Dorothee ;
Regina, Sandra ;
Rollin, Jerome ;
Gruel, Yves .
THROMBOSIS AND HAEMOSTASIS, 2010, 103 (01) :145-150
[9]   Hypercoagulability in patients with type 2 diabetes mellitus detected by a thrombin generation assay [J].
Tripodi, Armando ;
Branchi, Adriana ;
Chantarangkul, Veena ;
Clerici, Marigrazia ;
Merati, Giuliana ;
Artoni, Andrea ;
Mannucci, Pier Mannuccio .
JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2011, 31 (02) :165-172
[10]  
Verkleij CJ, 2010, CLIN APPL THROMB HEM