Pacing and sensing optimization of permanent His-bundle pacing in cardiac resynchronization therapy/implantable cardioverter defibrillators patients: value of integrated bipolar configuration

被引:33
作者
Su, Lan [1 ]
Xu, Lei [1 ]
Wu, Sheng-jie [1 ]
Huang, Wei-jian [1 ]
机构
[1] Wenzhou Med Univ, Dept Cardiol, Affiliated Hosp 1, Wenzhou 325000, Zhejiang, Peoples R China
来源
EUROPACE | 2016年 / 18卷 / 09期
关键词
His-bundle pacing; Sensing; Pacing thresholds; Integrated bipolar; Cardiac resynchronization therapy; METAANALYSIS; PERFORMANCE; THERAPY; SITE; LEAD;
D O I
10.1093/europace/euv306
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The clinical implementation of His-bundle pacing (HBP) has been limited by concern over higher capture thresholds (CTs) and lower R-wave amplitudes (RWAs), when compared with right ventricular (RV) pacing. The aim of this study was to assess the optimal pacing configuration for HBP lead when incorporated with cardiac resynchronization therapy/implantable cardioverter defibrillators (CRT-D/ICD) by testing of an integrated bipolar configuration. Methods and results HBP was achieved in 25 CRT-D and 13 ICD patients at implantation. Their RWA, CT@0.5 ms and impedance with His-bundle (HB) tip-RV coil, and HB unipolar and bipolar (tip-ring) configurations were measured acutely. Capture threshold in CRT-D patients was that needed to 'correct' complete left bundle block. Among all 16 CRT-D patients with permanent HBP, their RWA, CT@0.5 ms, and pacing impedance with HBP tip-RV coil and HBP tip-ring were measured at 1 month and 3 months follow-up. HigherRWA and lower CT were achieved with HB tip-RV coil configuration than either of the other two configurations at implantation (n = 38, P < 0.05, respectively). At 1 and 3 months follow-up for patients receiving permanent HBP, RWA and CT with HB tip-RV coil configuration remained stable and better than those with HB tip-ring configuration (n = 16, P < 0.05, respectively). Furthermore, HB lead pulse energy delivered with HB tip-RV coil configuration was also less than with HB tip-ring at 3 months (n = 16, P = 0.017). Conclusion Incorporation of HBP into a CRT-D/ICD system is feasible, and pacing thresholds/sensing can be optimized using a novel integrated bipolar configuration with the RV lead.
引用
收藏
页码:1399 / 1405
页数:7
相关论文
共 22 条
[1]   His-bundle pacing: Great concept, difficult in practice [J].
Almendral Garrote, Jesus .
REVISTA ESPANOLA DE CARDIOLOGIA, 2006, 59 (06) :534-536
[2]   Ventricular resynchronization therapy by direct His-bundle pacing using an internal cardioverter defibrillator [J].
Barba-Pichardo, Rafael ;
Sanchez, Ana Manovel ;
Fernandez-Gomez, Juan M. ;
Morina-Vazquez, Pablo ;
Venegas-Gamero, Jose ;
Herrera-Carranza, Manuel .
EUROPACE, 2013, 15 (01) :83-88
[3]   Permanent His-bundle pacing: seeking physiological ventricular pacing [J].
Barba-Pichardo, Rafael ;
Morina-Vazquez, Pablo ;
Fernandez-Gomez, Juan M. ;
Venegas-Gamero, Jose ;
Herrera-Carranza, Manuel .
EUROPACE, 2010, 12 (04) :527-533
[4]   Permanent His-bundle pacing maintains long-term ventricular synchrony and left ventricular performance, unlike conventional right ventricular apical pacing [J].
Catanzariti, Domenico ;
Maines, Massimiliano ;
Manica, Anna ;
Angheben, Carlo ;
Varbaro, Annamaria ;
Vergara, Giuseppe .
EUROPACE, 2013, 15 (04) :546-553
[5]   Permanent direct his bundle pacing does not induce ventricular dyssynchrony unlike conventional right ventricular apical pacing - An intrapatient acute comparison study [J].
Catanzariti, Domenico ;
Maines, Massimiliano ;
Cemin, Claudio ;
Broso, Gianpaolo ;
Marotta, Tiziana ;
Vergara, Giuseppe .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2006, 16 (02) :81-92
[6]   Physiologic Resynchronization Therapy: A Case of His Bundle Pacing Reversing Physiologic Conduction in a Patient with CHF and LBBB During 2 Years of Observation [J].
Dabrowski, Pawel ;
Kleinrok, Andrzej ;
Kozluk, Edward ;
Opolski, Grzegorz .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 (07) :813-817
[7]   Autopsy Analysis of the Implantation Site of a Permanent Selective Direct His Bundle Pacing Lead [J].
de Sa, Daniel D. Correa ;
Hardin, Nicholas J. ;
Crespo, Eric M. ;
Nicholas, Karolyn B. ;
Lustgarten, Daniel L. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2012, 5 (01) :244-U387
[8]   Permanent, direct his-bundle pacing - A novel approach to cardiac pacing in patients with normal His-purkinje activation [J].
Deshmukh, P ;
Casavant, DA ;
Romanyshyn, M ;
Anderson, K .
CIRCULATION, 2000, 101 (08) :869-877
[9]   Direct his-bundle pacing: Present and future [J].
Deshmukh, PM ;
Romanyshyn, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (06) :862-870
[10]   His or para-His pacing preserves left ventricular function in atrioventricular block: a double-blind, randomized, crossover study [J].
Kronborg, Mads B. ;
Mortensen, Peter T. ;
Poulsen, Steen H. ;
Gerdes, Jens C. ;
Jensen, Henrik K. ;
Nielsen, Jens C. .
EUROPACE, 2014, 16 (08) :1189-1196