Reproducibility of computer-aided volumetry of artificial small pulmonary nodules in ex vivo porcine lungs

被引:45
作者
Bolte, H
Riedel, C
Jahnke, T
Inan, N
Freitag, S
Kohl, G
Heller, M
Biederer, J
机构
[1] Univ Hosp Schleswig, Dept Diagnost Radiol, D-24105 Kiel, Germany
[2] Univ Hosp Schleswig, Inst Med Informat & Stat, D-24105 Kiel, Germany
[3] Siemens AG, Med Solut, Forchheim, Germany
关键词
computed tomography; lung nodule; volumetry; reproducibility; phantom;
D O I
10.1097/01.rli.0000191366.05586.4d
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The main purpose of this study was to investigate the reproducibility of computed tomography (CT)-based volumetric measurements of small pulmonary nodules. Methods: We implanted 70 artificial pulmonary nodules in 5 ex vivo porcine lungs in a dedicated chest phantom. The lungs were scanned 5 times consecutively with multislice-CT (collimation 16 X 0.75 mm, slice thickness 1 mm, reconstruction increment 0.7 mm). A commercial software package was used for lesion volumetry. The authors differentiated between intrascan reproducibility, interscan reproducibility, and results from semiautomatic and postprocesse volumetry. Results: Analysis of intrascan reproducibility revealed a mean variation coefficient of 6.2% for semiautomatic volumetry and of 0.7% for human adapted volumetry. For interscan reproducibility a mean variation coefficient of 9.2% and for human adapted volumetry a mean of 3.7% was detected. Conclusion: The presented volumetry software showed a high reproducibility that can be expected to detect nodule growth with a high degree of certainty.
引用
收藏
页码:28 / 35
页数:8
相关论文
共 38 条
[1]   Pulmonary nodules at chest CT: Effect of computer-aided diagnosis on radiologists' detection performance [J].
Awai, K ;
Murao, K ;
Ozawa, A ;
Komi, M ;
Hayakawa, H ;
Hori, S ;
Nishimura, Y .
RADIOLOGY, 2004, 230 (02) :347-352
[2]   Diagnostic performance of a flat-panel detector at low tube voltage in chest radiography -: A phantom study [J].
Bernhardt, TM ;
Rapp-Bernhardt, U ;
Lenzen, H ;
Röhl, FW ;
Diederich, S ;
Papke, K ;
Ludwig, K ;
Heindel, W .
INVESTIGATIVE RADIOLOGY, 2004, 39 (02) :97-103
[3]   Clinical evaluation of a software for automated localization of lung nodules at follow-up CT examinations [J].
Beyer, F ;
Wormanns, D ;
Novak, C ;
Shen, H ;
Odry, BL ;
Kohl, G ;
Heindel, W .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (06) :829-836
[4]   Artificial thorax for MR imaging studies in porcine heart-lung preparations [J].
Biederer, J ;
Heller, M .
RADIOLOGY, 2003, 226 (01) :250-255
[5]   Ex-vivo injection for implanting solid pulmonary nodules into porcine lungs for multi-slice CT [J].
Bolte, H ;
Müller-Hülsbeck, S ;
Riedel, C ;
Jahnke, T ;
Inan, N ;
Heller, M ;
Biederer, J .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (10) :1380-1384
[6]   Screening for early lung cancer with low-dose spiral CT: Prevalence in 817 asymptomatic smokers [J].
Diederich, S ;
Wormanns, D ;
Semik, M ;
Thomas, M ;
Lenzen, H ;
Roos, N ;
Heindel, W .
RADIOLOGY, 2002, 222 (03) :773-781
[7]   Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness [J].
Fischbach, F ;
Knollmann, F ;
Griesshaber, V ;
Freund, T ;
Akkol, E ;
Felix, R .
EUROPEAN RADIOLOGY, 2003, 13 (10) :2378-2383
[8]   Volumetric measurement of synthetic lung nodules with multi-detector row CT: Effect of various image reconstruction parameters and segmentation thresholds on measurement accuracy [J].
Goo, JM ;
Tongdee, T ;
Tongdee, R ;
Yeo, K ;
Hildebolt, CF ;
Bae, KT .
RADIOLOGY, 2005, 235 (03) :850-856
[9]   Growth rate of small lung cancers detected on mass CT screening [J].
Hasegawa, M ;
Sone, S ;
Takashima, S ;
Li, F ;
Yang, ZG ;
Maruyama, Y ;
Watanabe, T .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (876) :1252-1259
[10]   Neural networks for the analysis of small pulmonary nodules [J].
Henschke, CI ;
Yankelevitz, DF ;
Mateescu, I ;
Brettle, DW ;
Rainey, TG ;
Weingard, FS .
CLINICAL IMAGING, 1997, 21 (06) :390-399