Effective Test Bed of 380-V DC Distribution System Using Isolated Power Converters

被引:141
作者
Ryu, Myung-Hyo [1 ]
Kim, Ho-Sung [1 ]
Baek, Ju-Won [1 ]
Kim, Heung-Geun [2 ]
Jung, Jee-Hoon [3 ]
机构
[1] Korea Electrotechnol Res Inst, HVDC Res Div, Power Convers & Control Res Ctr, Chang Won 642120, South Korea
[2] Kyungpook Natl Univ, Dept Elect Engn, Coll IT Engn, Taegu 702701, South Korea
[3] Ulsan Natl Inst Sci & Technol, Sch Elect & Comp Engn, Ulsan 689798, South Korea
关键词
Dual active bridge (DAB) converter; isolated power converter; LLC resonant converter; test bed; 380-V direct current (dc) distribution system; ACTIVE BRIDGE CONVERTER; RESONANT CONVERTER; CONTROL STRATEGY; DC/DC CONVERTER; DESIGN; MANAGEMENT;
D O I
10.1109/TIE.2015.2399273
中图分类号
TP [自动化技术、计算机技术];
学科分类号
080201 [机械制造及其自动化];
摘要
This paper proposes an effective test bed for a 380-V dc distribution system using isolated power converters. The proposed test-bed system is composed of a grid-interactive ac-dc converter for regulating the dc-bus voltage, a bidirectional converter for the battery power interface, a renewable energy simulator, dc home appliances modified from conventional ac components, a dc distribution panel board, and its monitoring system. This paper discusses three isolated power converters, i.e., a bidirectional ac-dc converter, a bidirectional dc-dc converter, and a unidirectional dc-dc converter for the effective power interface of a dc bus. These isolated power converters are designed using a dual-active-bridge converter and the resonant topologies of CLLC and LLC. The proposed test-bed system was implemented using a 5-kW bidirectional ac-dc prototype converter, a 3-kW bidirectional dc-dc prototype converter, and a 3-kW unidirectional dc-dc prototype converter. Finally, the performance of the test-bed system has been verified using practical experiments of load variations and bidirectional power flow, employing the prototype converters.
引用
收藏
页码:4525 / 4536
页数:12
相关论文
共 33 条
[1]
[Anonymous], 2007 IEEE Power Eng. Soc. Gen. Meet. PES, DOI [DOI 10.1109/PES.2007.386130, 10.1109/PES.2007.386130.]
[2]
[Anonymous], P IEEE APEC
[3]
[Anonymous], P IEEE INTELEC
[4]
[Anonymous], P IEEE APEC
[5]
Performance of a series-parallel resonant DC/DC converter configured around an inductor-transformer utilizing transformer magnetics [J].
Chakraborty, C ;
Ishida, M .
IEEE TRANSACTIONS ON MAGNETICS, 2000, 36 (05) :3527-3529
[6]
Snubberless Bidirectional DC-DC Converter With New CLLC Resonant Tank Featuring Minimized Switching Loss [J].
Chen, Wei ;
Rong, Ping ;
Lu, Zhengyu .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (09) :3075-3086
[7]
Cvetkovic I, 2011, APPL POWER ELECT CO, P1251, DOI 10.1109/APEC.2011.5744753
[8]
A Distributed Control Strategy for Coordination of an Autonomous LVDC Microgrid Based on Power-Line Signaling [J].
Dragicevic, Tomislav ;
Guerrero, Josep M. ;
Vasquez, Juan C. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (07) :3313-3326
[9]
Optimal Trajectory Control of Burst Mode for LLC Resonant Converter [J].
Feng, Weiyi ;
Lee, Fred C. ;
Mattavelli, Paolo .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (01) :457-466
[10]
Bi-directional dc-dc converter for hybrid vehicles [J].
García, O ;
Flores, LA ;
Oliver, JA ;
Cobos, JA ;
de la Peña, J .
2005 IEEE 36TH POWER ELECTRONIC SPECIALISTS CONFERENCE (PESC), VOLS 1-3, 2005, :1881-1886