Sentinel lymph nodes in a swine model with melanoma: Contrast-enhanced lymphatic US

被引:132
作者
Goldberg, BB
Merton, DA
Liu, JB
Thakur, M
Murphy, GF
Needleman, L
Tornes, A
Forsberg, F
机构
[1] Thomas Jefferson Univ Hosp, Dept Radiol, Philadelphia, PA 19107 USA
[2] Thomas Jefferson Univ Hosp, Dept Pathol, Philadelphia, PA 19107 USA
[3] Amersham Hlth, Oslo, Norway
关键词
lymphatic system; radionuclide studies; US; melanoma;
D O I
10.1148/radiol.2303021440
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine if lymphatic channels and sentinel lymph nodes (SLNs) with and without metastases can be detected with lymphatic ultrasonography (US) after peritumoral injection of a US contrast agent and to determine if lymphatic US can be used to assess SLNs for the presence of metastatic infiltration. MATERIALS AND METHODS: Six swine with 17 melanomas were evaluated. Conventional gray-scale, color flow, and gray-scale phase-inversion harmonic US examinations were performed. A US contrast agent was administered in four sites around each melanoma (1-mL total dose). Lymphoscintigraphy was followed by injection of a blue dye and then dissection. SLNs identified at lymphatic US were characterized by two readers in consensus as normal or as having metastases; results were compared with histologic findings. Statistical analyses included the sign test and the kappa statistic. RESULTS: Lymphatic US depicted 28 SLNs, while lymphoscintigraphy depicted 27 "hot spots" suspected of representing SLNs (including two false-positive findings). Dissection after blue dye injection helped identify 31 SLNs. There were no false-positive US findings for SLN detection. Five of six nodes not seen with lymphoscintigraphy were detected with lymphatic US. The accuracy of SLN detection was 90% (28 of 31) for lymphatic US and 81% (25 of 31) for lymphoscintigraphy (P = .29). Lymphatic US correctly depicted metastases in 19 of 20 SLNs, and five of the eight normal SLNs were correctly characterized, with an accuracy of 86% (kappa = 0.62). CONCLUSION: Detection of SLNs with lymphatic US compared favorably with that at lymphoscintigraphy. Lymphatic US can depict metastases within the SLN, which was not possible with lymphoscintigraphy. (C) RSNA, 2004.
引用
收藏
页码:727 / 734
页数:8
相关论文
共 28 条
[1]   Sentinel node staging of early breast cancer using lymphoscintigraphy and the intraoperative gamma-detecting probe [J].
Alazraki, NP ;
Styblo, T ;
Grant, SF ;
Cohen, C ;
Larsen, T ;
Aarsvold, JN .
SEMINARS IN NUCLEAR MEDICINE, 2000, 30 (01) :56-64
[2]   Lymphatic mapping and sentinel node biopsy in the patient with breast cancer [J].
Albertini, JJ ;
Lyman, GH ;
Cox, C ;
Yeatman, T ;
Balducci, L ;
Ku, NN ;
Shivers, S ;
Berman, C ;
Wells, K ;
Rapaport, D ;
Shons, A ;
Horton, J ;
Greenberg, H ;
Nicosia, S ;
Clark, R ;
Cantor, A ;
Reintgen, DS .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (22) :1818-1822
[3]   Improved imaging of liver metastases with stimulated acoustic emission in the late phase of enhancement with the US contrast agent SH U 508A: Early experience [J].
Blomley, MJK ;
Albrecht, T ;
Cosgrove, DO ;
Patel, N ;
Jayaram, V ;
Butler-Barnes, J ;
Eckersley, RJ ;
Bauer, A ;
Schlief, R .
RADIOLOGY, 1999, 210 (02) :409-416
[4]   Vital dyes in sentinel node localization [J].
Bostick, PJ ;
Giuliano, AE .
SEMINARS IN NUCLEAR MEDICINE, 2000, 30 (01) :18-24
[5]   MANAGEMENT OF THE REGIONAL LYMPH-NODES IN PATIENTS WITH CUTANEOUS MALIGNANT-MELANOMA [J].
COCHRAN, AJ ;
WEN, MDDR ;
MORTON, DL .
WORLD JOURNAL OF SURGERY, 1992, 16 (02) :214-221
[6]  
Eshima D, 2000, SEMIN NUCL MED, V30, P25
[7]   Hepatic tumor detection: MR Imaging and conventional US versus pulse-inversion harmonic US of NC100100 during its reticuloendothelial system-specific phase [J].
Forsberg, F ;
Piccoli, CW ;
Liu, JB ;
Rawool, NM ;
Merton, DA ;
Mitchell, DG ;
Goldberg, BB .
RADIOLOGY, 2002, 222 (03) :824-829
[8]  
Forsberg F, 2000, J ULTRAS MED, V19, P557
[9]  
GOLDBERG BB, 1997, RADIOLOGY, V205, P417
[10]   Lymphoscintigraphic identification of sentinel lymph nodes:: Clinical evaluation of 0.22-μm filtration of Tc-99m sulfur colloid [J].
Goldfarb, LR ;
Alazraki, NP ;
Eshima, D ;
Eshima, LA ;
Herda, SC ;
Halkar, RK .
RADIOLOGY, 1998, 208 (02) :505-509