The reliability and validity of the physiological cost index in healthy subjects while walking on 2 different tracks

被引:41
作者
Graham, RC [1 ]
Smith, NM [1 ]
White, CM [1 ]
机构
[1] Kings Coll London, Physiotherapy Div, London, England
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 2005年 / 86卷 / 10期
关键词
heart rate; oxygen consumption; rehabilitation; walking;
D O I
10.1016/j.apmr.2005.04.022
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To investigate the reliability and validity of the Physiological Cost Index (PCI) scores, as a measure of energy expenditure, when healthy subjects walk on 2 different tracks (20-m and 12-m figure eight tracks). \ Design: Intra- and interrater reliability and construct validity. Setting: Physiotherapy division of a university in London, UK. Participants: Forty healthy subjects (15 men, 25 women; mean age +/- standard deviation, 34.5 +/- 12.6y). Interventions: Not applicable. Main Outcome Measures: Heart rate (in beats/min) and speed (in m/min) were used to calculate the PCI (in beats/m). Rate of oxygen consumption (VO2, in mL(.)kg(-1.)min(-1)) and oxygen cost (EO2 in mL(.)kg(-1.)m(-1)) were used as criterion estimates of energy cost EO2. Pearson correlation coefficients between the PCI, components of the PCI, EO2, and VO2 were used to quantify validity. Intrarater reliability was assessed in all participants and interrater reliability was assessed on a subset of 13 subjects using intraclass correlation coefficients and Bland-Altman plots. Results: Intrarater (r = .73, r = .79) and interrater (r = .62, r = .66) reliability were acceptable between PCI scores from 20-m and 12-m tracks, respectively. Correlations between VO2 and EO2 with PCI were weak. PCI scores from the 20-m track were significantly lower than those on the 12-m track (P = .002). Subjects walked significantly faster on the 20-m track (P < .001). Results suggest a large difference in PCI scores would be necessary to indicate a "true" alteration in performance (52% for 20-m track, 43.4% for the 12-m track). Conclusions: The PCI is reliable but not valid as a measure of the energy cost of walking in healthy subjects, on either track. The 20-m track is recommended for clinical use because it enables subjects to walk at a faster pace.
引用
收藏
页码:2041 / 2046
页数:6
相关论文
共 24 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]  
Armitage P., 2002, STAT METHODS MED RES
[3]  
Bailey MJ., 1995, Physiotherapy, V81, P618
[4]   Variability of energy-consumption measures in children with cerebral palsy [J].
Bowen, TR ;
Lennon, N ;
Castagno, P ;
Miller, F ;
Richards, J .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1998, 18 (06) :738-742
[5]   High- or low-technology measurements of energy expenditure in clinical gait analysis? [J].
Boyd, R ;
Fatone, S ;
Rodda, J ;
Olesch, C ;
Starr, R ;
Cullis, E ;
Gallagher, D ;
Carlin, JB ;
Nattrass, GR ;
Graham, K .
DEVELOPMENTAL MEDICINE AND CHILD NEUROLOGY, 1999, 41 (10) :676-682
[6]   Relation between abnormal patterns of muscle activation and response to common peroneal nerve stimulation in hemiplegia [J].
Burridge, JH ;
McLellan, DL .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2000, 69 (03) :353-361
[7]  
Corry IS, 1996, DEV MED CHILD NEUROL, V38, P585
[8]   Energy expenditure during gait using the walkabout and isocentric reciprocal gait orthoses in persons with paraplegia [J].
Harvey, LA ;
Davis, GM ;
Smith, EB ;
Engel, S .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1998, 79 (08) :945-949
[9]   A new method of using heart rate to represent energy expenditure: The Total Heart Beat Index [J].
Hood, VL ;
Granat, MH ;
Maxwell, DJ ;
Hasler, JP .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2002, 83 (09) :1266-1273
[10]  
Humerickhouse Robyn, 1993, Physical and Occupational Therapy in Geriatrics, V11, P35