Augmenting the Impact of Technology Adoption With Financial Incentive to Improve Radiology Report Signature Times

被引:25
作者
Andriole, Katherine P. [1 ,2 ]
Prevedello, Luciano M. [2 ]
Dufault, Allen
Pezeshk, Parham
Bransfield, Robert
Hanson, Richard
Doubilet, Peter M. [2 ]
Seltzer, Steven E. [2 ]
Khorasani, Ramin [2 ]
机构
[1] Brigham & Womens Hosp, Dept Radiol, Ctr Evidence Based Imaging, Brookline, MA 02445 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
关键词
Report signature times; turnaround times; speech recognition report generation; technology adoption; imaging informatics; SPEECH RECOGNITION;
D O I
10.1016/j.jacr.2009.11.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Radiology report signature time (ST) can be a substantial component of total report turnaround time. Poor turnaround time resulting from lengthy ST can adversely affect patient care. The combination of technology adoption with financial incentive was evaluated to determine if ST improvement can be augmented and sustained. Methods: This prospective study was performed at a 751-bed, urban, tertiary care adult teaching hospital. Test-site imaging volume approximated 48,000 examinations per month. The radiology department has 100 trainees and 124 attending radiologists serving multiple institutions. Over a study period of 4 years and 4 months, three interventions focused on radiologist signature performance were implemented: 1) a notification paging application that alerted radiologists when reports were ready for signature, 2) a picture archiving and communications systems (PACS)integrated speech recognition report generation system, and 3) a departmental financial incentive to reward radiologists semianniially for ST performance. Signature time was compared before and after the interventions. Wilcoxon and linear regression statistical analyses were used to assess the significance of trends. Results: Technology adoption (paging plus speech recognition) reduced median ST from >5 to <1 hour (P<.001) and 80th-percentile ST from >24 to 15 to 18 hours (P<.001). Subsequent addition of a financial incentive further improved 80th-percentile ST to 4 to 8 hours (P<.001). The gains in median and 80th-percentile ST were sustained over the final 31 months of the study period. Conclusions: Technology interventions coupled with financial incentive can result in synergistic and sustainable improvement in radiologist report-signing behavior. The addition of a financial incentive leads to better performance than that achievable through technology alone.
引用
收藏
页码:198 / 204
页数:7
相关论文
共 15 条
[1]  
American College of Radiologists, 2005, ACR PRACT GUID COMM
[2]   Radiology report turnaround: expectations and solutions [J].
Boland, G. W. L. ;
Guimaraes, A. S. ;
Mueller, P. R. .
EUROPEAN RADIOLOGY, 2008, 18 (07) :1326-1328
[3]   RADIOLOGY REPORTING - ATTITUDES OF REFERRING PHYSICIANS [J].
CLINGER, NJ ;
HUNTER, TB ;
HILLMAN, BJ .
RADIOLOGY, 1988, 169 (03) :825-826
[4]   Process modification and emergency department radiology service [J].
DeFlorio R. ;
Coughlin B. ;
Coughlin R. ;
Li H. ;
Santoro J. ;
Akey B. ;
Favreau M. .
Emergency Radiology, 2008, 15 (6) :405-412
[5]   Improvement of Report Workflow and Productivity Using Speech Recognition-A Follow-up Study [J].
Koivikko, Mika P. ;
Kauppinen, Tomi ;
Ahovuo, Juhani .
JOURNAL OF DIGITAL IMAGING, 2008, 21 (04) :378-382
[6]   Impact of speech recognition on radiologist productivity [J].
Langer, SG .
JOURNAL OF DIGITAL IMAGING, 2002, 15 (04) :203-209
[7]  
Langer Steve G, 2002, J Digit Imaging, V15 Suppl 1, P234, DOI 10.1007/s10278-002-5011-3
[8]   The implementation of speech recognition in an electronic radiology practice [J].
Lemme, PJ ;
Morin, RL .
JOURNAL OF DIGITAL IMAGING, 2000, 13 (02) :153-154
[9]   Impact of PACS deployment strategy on dictation turnaround time of chest radiographs [J].
Lepanto, L ;
Paré, G ;
Gauvin, A .
ACADEMIC RADIOLOGY, 2006, 13 (04) :447-452
[10]   Impact of electronic signature on radiology report turnaround time [J].
Lepanto, L .