Navigated intraoperative analysis of lower limb alignment

被引:47
作者
Hankemeier, S
Hufner, T
Wang, GL
Kendoff, D
Zheng, GY
Richter, M
Gosling, T
Nolte, L
Krettek, C
机构
[1] Hannover Med Sch MHH, Trauma Dept, D-30625 Hannover, Germany
[2] Univ Bern, Maurice E Muller Res Ctr, Inst Surg Technol & Biomech, Bern, Switzerland
关键词
navigation; mechanical axis; imaging; accuracy; deformities; fractures; arthroplasties;
D O I
10.1007/s00402-005-0038-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Accurate intraoperative assessment of lower limb alignment is crucial for the treatment of long bone fractures, implantation of knee arthroplasties and correction of deformities. During orthopaedic surgery, exact real time control of the mechanical axis is strongly desirable. The aim of this study was to compare conventional intraoperative analysis of the mechanical axis by the cable method with continuous, 3-dimensional imaging with a navigation system. Materials and methods: Twenty legs of fresh human cadaver were randomly assigned to conventional analysis with the cable method (n=10) or navigated analysis with a fluoroscopy based navigation system (n=10). The intersection of the mechanical axis with the tibia plateau was presented as percentage of the tibia plateau (beginning with 0% at the medial border and ending with 100% laterally). CT-scans were performed for all legs and the CT-values of the mechanical axis were compared to the measurements after cable method and navigation. Furthermore, the radiation time and dose area product of both groups for single analysis of the mechanical axis was compared. Results: Conventional evaluation of the mechanical axis by the cable method showed 6.0 +/- 3.1% difference compared to the analysis by CT. In the navigated group the difference was 2.6 +/- 1.8% (P=0.008). Radiation time and dose area product were highly significantly lower after conventional measurement. Conclusions: Navigated intraoperative evaluation of the mechanical axis offers increased accuracy compared to conventional intraoperative analysis. Furthermore, navigation provides continuous control not only of the mechanical axis, but also of the sagittal and transverse plane. Using the cable method, radiation exposure depends on the number of measurements and is lower compared to the navigation system for single intraoperative analysis of the mechanical axis, but may be higher in case of repeated intraoperative measurements.
引用
收藏
页码:531 / 535
页数:5
相关论文
共 27 条
[1]
Effect of high tibial flexion osteotomy on cartilage pressure and joint kinematics: a biomechanical study in human cadaveric knees - Winner of the AGA-DonJoy Award 2004 [J].
Agneskirchner, JD ;
Hurschler, C ;
Stukenborg-Colsman, C ;
Imhoff, AB ;
Lobenhoffer, P .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2004, 124 (09) :575-584
[2]
Alignment in total knee arthroplasty -: A comparison of computer-assisted surgery with the conventional technique [J].
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Lüring, C ;
Zurakowski, D ;
Grifka, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (05) :682-687
[3]
CHAO EYS, 1994, ORTHOP CLIN N AM, V25, P379
[4]
HERNIGOU P, 1987, J BONE JOINT SURG AM, V69A, P332
[5]
HSU RWW, 1990, CLIN ORTHOP RELAT R, P215
[6]
CORONAL ALIGNMENT AFTER TOTAL KNEE REPLACEMENT [J].
JEFFERY, RS ;
MORRIS, RW ;
DENHAM, RA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05) :709-714
[7]
Unicompartmental knee prosthesis implantation with a non-image-based navigation system: rationale, technique, case-control comparative study with a conventional instrumented implantation [J].
Jenny, JY ;
Boeri, C .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2003, 11 (01) :40-45
[8]
Computer aided high tibial open wedge osteotomy [J].
Keppler, P ;
Gebhard, N ;
Grützner, PA ;
Wang, GL ;
Zheng, GY ;
Hüfner, T ;
Hankemeier, S ;
Nolte, LP .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2004, 35 :68-78
[9]
KETTELKAMP DB, 1988, CLIN ORTHOP RELAT R, P159
[10]
Intraoperative control of axes, rotation and length in femoral and tibial fractures [J].
Krettek, C ;
Miclau, T ;
Grün, O ;
Schandelmaier, P ;
Tscherne, H .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1998, 29 :29-39