Deconvolution problem to produce ultrasonic short pulses

被引:6
作者
Salazar, J [1 ]
Turó, A [1 ]
Chávez, A [1 ]
Ortega, JA [1 ]
García, MJ [1 ]
机构
[1] Univ Politecn Catalunya, Dept Elect Engn, ES-08034 Barcelona, Spain
关键词
inverse filtering; system identification; ultrasonic short pulse;
D O I
10.1049/ip-smt:19982325
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The quality of a medical image is highly dependent on the axial resolution of the ultrasonic transducer, i.e. the duration of the transmitted and received ultrasonic pulses. The emission of short ultrasonic pulses can be accomplished by precompensating the electrical excitation applied to the transducer. To achieve this the impulse response of the transducer has to be determined beforehand. The paper presents a different approach to determine the impulse response of the transducer by using common deconvolution techniques. The main advantages of this approach are that it is easily programmable and that it avoids interpretation, which is inherent deconvolution techniques. To prove the effectiveness of the method, the impulse response obtained is used to modify the electrical excitation applied to a piezoelectric ultrasonic transducer to produce a short emitted/received signal. Experimental results show that a transducer having more than one resonance peak may be compensated resulting in an increase of axial resolution.
引用
收藏
页码:317 / 320
页数:4
相关论文
共 11 条
[1]   AN OPTIMIZATION TECHNIQUE FOR ITERATIVE FREQUENCY-DOMAIN DECONVOLUTION [J].
BENNIA, A ;
RIAD, SM .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1990, 39 (02) :358-362
[2]   DESIGN OF EFFICIENT BROAD-BAND PIEZOELECTRIC TRANSDUCERS [J].
DESILETS, CS ;
FRASER, JD ;
KINO, GS .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1978, 25 (03) :115-125
[3]   A THEORETICAL APPROACH FOR INVERSE FILTER DESIGN IN ULTRASONIC APPLICATIONS [J].
HAYWARD, G ;
LEWIS, JE .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1989, 36 (03) :356-364
[4]   EFFECTS OF BACKING AND MATCHING ON PERFORMANCE OF PIEZOELECTRIC CERAMIC TRANSDUCERS [J].
KOSSOFF, G .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1966, SU13 (01) :20-&
[5]   AN OPTIMIZATION CRITERION FOR ITERATIVE DECONVOLUTION [J].
PARRUCK, B ;
RIAD, SM .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1983, 32 (01) :137-140
[7]  
Proakis G., 1992, DIGITAL SIGNAL PROCE
[8]  
SALAZAR J, 1996, P IEEE INSTR MEAS TE, V1, P394
[9]   DESIGN OF LOW-LOSS WIDEBAND ULTRASONIC TRANSDUCERS FOR NON-INVASIVE MEDICAL APPLICATION [J].
SOUQUET, J ;
DEFRANOULD, P ;
DESBOIS, J .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1979, 26 (02) :75-81
[10]   Combining pulse compression and adaptive drive signal design to inverse filter the transducer system response and improve resolution in medical ultrasound [J].
Venkatraman, S ;
Rao, NAHK .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1996, 34 (04) :318-320