MR arthrography of the glenohumeral joint: Two concentrations of gadoteridol versus Ringer solution as the intraarticular contrast material

被引:34
作者
Binkert, CA
Zanetti, M
Gerber, C
Hodler, J
机构
[1] Univ Hosp Balgrist, Dept Radiol, CH-8008 Zurich, Switzerland
[2] Univ Hosp Balgrist, Dept Orthoped Surg, CH-8008 Zurich, Switzerland
关键词
arthrography; contrast media; comparative studies; gadolinium; magnetic resonance (MR); shoulder; tendons; injuries;
D O I
10.1148/radiology.220.1.r01jn03219
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
PURPOSE: To compare two concentrations of gadoteridol with Ringer solution as the contrast material for magnetic resonance (MR) arthrography of the glenohumeral joint. MATERIALS AND METHODS: One hundred fifty-six consecutive MR arthrograms were randomly obtained with either 2 mmol/L gadoteridol (n = 52), 4 mmol/L gadoteridol (n = 52), or Ringer solution (n = 52). MR arthrograms were assessed quantitatively (for contrast-to-noise ratio [CNR]) and qualitatively (for overall image quality, image contrast, degree of joint distention, and motion artifacts). MR diagnoses were compared with arthroscopic or surgical reports in 88 patients. RESULTS: The mean CNR at imaging was 40.4 with 2 mmol/L gadoteridol, 45.6 with 4 mmol/L gadoteridol, and 48.7 with Ringer solution. the CNR with 2 mmol/L gadoteridol was significantly lower than that with 4 mmol/L gadoteridol (P = .025) and Ringer solution (P = .012). Qualitative differences between the two gadoteridol concentrations were not significant. Ringer solution was significantly worse with regard to overall quality, motion artifacts, image contrast, and joint distention compared with both gadoteridol concentrations. Ringer solution was slightly more sensitive and less specific than the gadoteridol solutions in the detection of supraspinatus tears and less sensitive and more specific in enabling diagnosis of superior labrum anteroposterior lesions. CONCLUSION: MR arthrograms of the shoulder obtained with gadoteridol and those obtained with Ringer solution provided equivalent diagnostic accuracy. The authors, however, preferred the image quality of the gadoteridol-enhanced arthrograms.
引用
收藏
页码:219 / 224
页数:6
相关论文
共 18 条
[1]
ALTMAN DG, 1991, SOME COMMON PROBLEMS, P396
[2]
Superior labrum anterior-posterior lesions: Diagnosis with MR arthrography of the shoulder [J].
Bencardino, JT ;
Beltran, J ;
Rosenberg, ZS ;
Rokito, A ;
Schmahmann, S ;
Mota, J ;
Mellado, JM ;
Zuckerman, J ;
Cuomo, F ;
Rose, D .
RADIOLOGY, 2000, 214 (01) :267-271
[3]
THE EFFECT IN-VITRO OF IRRIGATING SOLUTIONS ON INTACT RAT ARTICULAR-CARTILAGE [J].
BULSTRA, SK ;
KUIJER, R ;
EERDMANS, P ;
VANDERLINDEN, AJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (03) :468-470
[4]
GLENOHUMERAL LIGAMENTS AND SHOULDER CAPSULAR MECHANISM - EVALUATION WITH MR ARTHROGRAPHY [J].
CHANDNANI, VP ;
GAGLIARDI, JA ;
MURNANE, TG ;
BRADLEY, YC ;
DEBERARDINO, TA ;
SPAETH, J ;
HANSEN, MF .
RADIOLOGY, 1995, 196 (01) :27-32
[5]
MR ARTHROGRAPHY OF THE SHOULDER - COMPARISON WITH CONVENTIONAL MR IMAGING [J].
FLANNIGAN, B ;
KURSUNOGLUBRAHME, S ;
SNYDER, S ;
KARZEL, R ;
DELPIZZO, W ;
RESNICK, D .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (04) :829-832
[6]
POTENTIAL CONTRAST AGENTS FOR MR ARTHROGRAPHY - INVITRO EVALUATION AND PRACTICAL OBSERVATIONS [J].
HAJEK, PC ;
SARTORIS, DJ ;
NEUMANN, CH ;
RESNICK, D .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (01) :97-104
[7]
ROTATOR CUFF DISEASE - ASSESSMENT WITH MR ARTHROGRAPHY VERSUS STANDARD MR IMAGING IN 36 PATIENTS WITH ARTHROSCOPIC CONFIRMATION [J].
HODLER, J ;
KURSUNOGLUBRAHME, S ;
SNYDER, SJ ;
CERVILLA, V ;
KARZEL, RP ;
SCHWEITZER, ME ;
FLANNIGAN, BD ;
RESNICK, D .
RADIOLOGY, 1992, 182 (02) :431-436
[8]
Effect of field strength on MR images: Comparison of the same subject at 0.5, 1.0, and 1.5 T [J].
Maubon, AJ ;
Ferru, JM ;
Berger, V ;
Soulage, MC ;
DeGraef, M ;
Aubas, P ;
Coupeau, P ;
Dumont, E ;
Rouanet, JP .
RADIOGRAPHICS, 1999, 19 (04) :1057-1067
[9]
ROTATOR CUFF - EVALUATION WITH FAT-SUPPRESSED MR ARTHROGRAPHY [J].
PALMER, WE ;
BROWN, JH ;
ROSENTHAL, DI .
RADIOLOGY, 1993, 188 (03) :683-687
[10]
Subscapularis tendon tears: Detection and grading at MR arthrography [J].
Pfirrmann, CWA ;
Zanetti, M ;
Weishaupt, D ;
Gerber, C ;
Hodler, J .
RADIOLOGY, 1999, 213 (03) :709-714