Poor interobserver reliability of AO classification of fractures of the distal radius -: Additional computed tomography is of minor value

被引:60
作者
Flinkkilä, T
Nikkola-Sihto, A
Kaarela, O
Pääkkö, E
Raatikainen, T
机构
[1] Oulu Univ Hosp, Div Orthopaed & Trauma Surg, SF-90220 Oulu, Finland
[2] Oulu Univ Hosp, Div Hand Surg, SF-90220 Oulu, Finland
[3] Oulu Univ Hosp, Dept Diagnost Radiol, SF-90220 Oulu, Finland
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1998年 / 80B卷 / 04期
关键词
D O I
10.1302/0301-620X.80B4.8511
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Interobserver reliability of the AO system of classification of fractures of the distal radius was assessed using plain radiographs and CT. Five observers classified 30 Colles'-type fractures using only plain radiographs; two months later they were reclassified using CT in addition. Interobserver reliability was poor in both series when detailed classification was used. By reducing the categories to five, interobserver reliability was slightly improved, but was still poor. When only tno AO types were used, the reliability mas moderate using plain radiographs and good to excellent with the addition of CT. The use of CT as well as plain radiographs brings interobserver reliability to a good level in assessment of the presence or absence of articular involvement, hut is otherwise of minor value in improving the interobserver reliability of the AO system of classification of fractures of the distal radius.
引用
收藏
页码:670 / 672
页数:3
相关论文
共 23 条
[1]
Classification of distal radius fractures: An analysis of interobserver reliability and intraobserver reproducibility [J].
Andersen, DJ ;
Blair, WF ;
Steyers, CM ;
Adams, BD ;
ElKhouri, GY ;
Brandser, EA .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1996, 21A (04) :574-582
[2]
OLDER CLASSIFICATION OF COLLES FRACTURES - GOOD INTRAOBSERVER AND INTEROBSERVER REPRODUCIBILITY IN 185 CASES [J].
ANDERSEN, GR ;
RASMUSSEN, JB ;
DAHL, B ;
SOLGAARD, S .
ACTA ORTHOPAEDICA SCANDINAVICA, 1991, 62 (05) :463-464
[3]
Evaluation of the Neer system of classification of proximal humeral fractures with computerized tomographic scans and plain radiographs [J].
Bernstein, J ;
Adler, LM ;
Blank, JE ;
Dalsey, RM ;
Williams, GR ;
Iannotti, JP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (09) :1371-1375
[4]
Taxonomy and treatment - a classification of fracture classifications [J].
Bernstein, J ;
Monaghan, BA ;
Silber, JS ;
DeLong, WG .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (05) :706-707
[5]
COLTON JL, 1997, J BONE JOINT SURG BR, V79, P708
[6]
TREATMENT OF DISPLACED ARTICULAR FRACTURES OF THE RADIUS [J].
FERNANDEZ, DL ;
GEISSLER, WB .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1991, 16A (03) :375-384
[7]
Fleiss JL, 1981, STAT METHODS RATES P
[8]
Intracarpal soft-tissue lesions associated with an intra-articular fracture of the distal end of the radius [J].
Geissler, WB ;
Freeland, AE ;
Savoie, FH ;
McIntyre, LW ;
Whipple, TL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (03) :357-365
[9]
COMPUTERIZED TOMOGRAPHIC EVALUATION OF ACUTE DISTAL RADIAL FRACTURES [J].
JOHNSTON, GHF ;
FRIEDMAN, L ;
KRIEGLER, JC .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1992, 17A (04) :738-744
[10]
Consistency of AO fracture classification for the distal radius [J].
Kreder, HJ ;
Hanel, DP ;
McKee, M ;
Jupiter, J ;
McGillivary, G ;
Swiontkowski, MF .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (05) :726-731