Technical Note: U-net-generated synthetic CT images for magnetic resonance imaging-only prostate intensity-modulated radiation therapy treatment planning

被引:83
作者
Chen, Shupeng [1 ]
Qin, An [1 ]
Zhou, Dingyi [2 ]
Yan, Di [1 ]
机构
[1] William Beaumont Hosp, Dept Radiat Oncol, 3601 W 13 Mile Rd, Royal Oak, MI 48073 USA
[2] Wuhan Univ, Renmin Hosp, Dept Oncol, Wuhan, Hubei, Peoples R China
关键词
deep learning; IMRT; prostate; synthetic CT; U-net; CONVOLUTIONAL NEURAL-NETWORK; ELECTRON-DENSITY; MRI; RADIOTHERAPY; HEAD; NECK;
D O I
10.1002/mp.13247
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Clinical implementation of magnetic resonance imaging (MRI)-only radiotherapy requires a method to derive synthetic CT image (S-CT) for dose calculation. This study investigated the feasibility of building a deep convolutional neural network for MRI-based S-CT generation and evaluated the dosimetric accuracy on prostate IMRT planning. Methods A paired CT and T2-weighted MR images were acquired from each of 51 prostate cancer patients. Fifteen pairs were randomly chosen as tested set and the remaining 36 pairs as training set. The training subjects were augmented by applying artificial deformations and feed to a two-dimensional U-net which contains 23 convolutional layers and 25.29 million trainable parameters. The U-net represents a nonlinear function with input an MR slice and output the corresponding S-CT slice. The mean absolute error (MAE) of Hounsfield unit (HU) between the true CT and S-CT images was used to evaluate the HU estimation accuracy. IMRT plans with dose 79.2 Gy prescribed to the PTV were applied using the true CT images. The true CT images then were replaced by the S-CT images and the dose matrices were recalculated on the same plan and compared to the one obtained from the true CT using gamma index analysis and absolute point dose discrepancy. Results The U-net was trained from scratch in 58.67 h using a GP100-GPU. The computation time for generating a new S-CT volume image was 3.84-7.65 s. Within body, the (mean +/- SD) of MAE was (29.96 +/- 4.87) HU. The 1%/1 mm and 2%/2 mm gamma pass rates were over 98.03% and 99.36% respectively. The DVH parameters discrepancy was less than 0.87% and the maximum point dose discrepancy within PTV was less than 1.01% respect to the prescription. Conclusion The U-net can generate S-CT images from conventional MR image within seconds with high dosimetric accuracy for prostate IMRT plan.
引用
收藏
页码:5659 / 5665
页数:7
相关论文
共 42 条
[1]  
Abadi M, 2016, OSDI 2016, P265
[2]  
Andreasen D, 2016, SPIE 2016, P33
[3]  
[Anonymous], ICLR 2015
[4]   Synthetic CT for MRI-based liver stereotactic body radiotherapy treatment planning [J].
Bredfeldt, Jeremy S. ;
Liu, Lianli ;
Feng, Mary ;
Cao, Yue ;
Balter, James M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (08) :2922-2934
[5]   MR image-based synthetic CT for IMRT prostate treatment planning and CBCT image-guided localization [J].
Chen, Shupeng ;
Quan, Hong ;
Qin, An ;
Yee, Seonghwan ;
Yan, Di .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03) :236-245
[6]  
Chollet F., KERAS DEEP LEARNING
[7]  
Cicek O., MICCAI 2016
[8]   Multi-Atlas based pseudo-CT Synthesis using Multimodal Image Registration and Local Atlas Fusion Strategies [J].
Degen, Johanna ;
Heinrich, Mattias P. .
PROCEEDINGS OF 29TH IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION WORKSHOPS, (CVPRW 2016), 2016, :600-608
[9]   Automatic Substitute Computed Tomography Generation and Contouring for Magnetic Resonance Imaging (MRI)-Alone External Beam Radiation Therapy From Standard MRI Sequences [J].
Dowling, Jason A. ;
Sun, Jidi ;
Pichler, Peter ;
Rivest-Henault, David ;
Ghose, Soumya ;
Richardson, Haylea ;
Wratten, Chris ;
Martin, Jarad ;
Arm, Jameen ;
Best, Leah ;
Chandra, Shekhar S. ;
Fripp, Jurgen ;
Menk, Frederick W. ;
Greer, Peter B. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (05) :1144-1153
[10]   An Atlas-Based Electron Density Mapping Method for Magnetic Resonance Imaging (MRI)-Alone Treatment Planning and Adaptive MRI-Based Prostate Radiation Therapy [J].
Dowling, Jason A. ;
Lambert, Jonathan ;
Parker, Joel ;
Salvado, Olivier ;
Fripp, Jurgen ;
Capp, Anne ;
Wratten, Chris ;
Denham, James W. ;
Greer, Peter B. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (01) :E5-E11