Coronary artery imaging using contrast-enhanced 3D segmented EPI

被引:19
作者
Deshpande, VS [1 ]
Wielopolski, PA [1 ]
Shea, SM [1 ]
Carr, J [1 ]
Zheng, J [1 ]
Li, DB [1 ]
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
关键词
magnetic resonance imaging (MRI); MR angiography; coronary arteries; contrast agents; segmented echo-planar imaging (SEPI);
D O I
10.1002/jmri.1095
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of the work was to evaluate the effectiveness of extracellular contrast media in improving MR coronary angiography using breath-hold segmented echo-planar imaging (SEPI). Two protocols were designed to optimize the inversion recovery-prepared contrast-enhanced SEPI method. In 15 healthy volunteers, significant Improvements In signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel sharpness, and length of visualization were observed post-contrast. The method with two targeted scans to cover the left and right arteries, respectively, following separate 20-mL contrast injections, was found to yield thinner slices and longer right coronary artery (RCA) visualization than a single scan following a 40-mL contrast injection without compromising SNR and CNR. In conclusion, extracellular contrast media substantially improves the delineation of coronary arteries with SEPI. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:676 / 681
页数:6
相关论文
共 27 条
[1]  
BECK GM, 1999, P 7 ANN M ISMRM PHIL
[2]  
Botnar RM, 1999, JMRI-J MAGN RESON IM, V10, P821, DOI 10.1002/(SICI)1522-2586(199911)10:5<821::AID-JMRI29>3.0.CO
[3]  
2-7
[4]   CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST [J].
BRITTAIN, JH ;
HU, BS ;
WRIGHT, GA ;
MEYER, CH ;
MACOVSKI, A ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :689-696
[5]   ANALYSIS OF FLOW EFFECTS IN ECHO-PLANAR IMAGING [J].
BUTTS, K ;
RIEDERER, SJ .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (03) :285-293
[6]   THEORETICAL ASPECTS OF MOTION SENSITIVITY AND COMPENSATION IN ECHO-PLANAR IMAGING [J].
DUERK, JL ;
SIMONETTI, OP .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (06) :643-650
[7]   CORONARY-ARTERIES - BREATH-HOLD MR ANGIOGRAPHY [J].
EDELMAN, RR ;
MANNING, WJ ;
BURSTEIN, D ;
PAULIN, S .
RADIOLOGY, 1991, 181 (03) :641-643
[8]   Coronary arteries: Breath-hold, gadolinium-enhanced, three-dimensional MR angiography [J].
Goldfarb, JW ;
Edelman, RR .
RADIOLOGY, 1998, 206 (03) :830-834
[9]   IMAGE-RECONSTRUCTION USING PROJECTION ONTO CONVEX-SETS, MODEL CONSTRAINTS, AND LINEAR PREDICTION-THEORY FOR THE REMOVAL OF PHASE, MOTION, AND GIBBS ARTIFACTS IN MAGNETIC-RESONANCE AND ULTRASOUND IMAGING [J].
HAACKE, EM ;
LIANG, ZP ;
BOADA, F .
OPTICAL ENGINEERING, 1990, 29 (05) :555-566
[10]   MEASUREMENT OF SIGNAL INTENSITIES IN THE PRESENCE OF NOISE IN MR IMAGES [J].
HENKELMAN, RM .
MEDICAL PHYSICS, 1985, 12 (02) :232-233