Performance of gas turbine-based plants during frequency drops

被引:52
作者
Kakimoto, N [1 ]
Baba, K [1 ]
机构
[1] Kyoto Univ, Kyoto 6068501, Japan
关键词
combined cycle; dynamic models; gas turbine; plant trip-out; under frequency;
D O I
10.1109/TPWRS.2003.814884
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 [电气工程]; 0809 [电子科学与技术];
摘要
A combined cycle power plant, which combines a gas turbine and a steam turbine, can achieve high energy efficiency. Many combined cycle plants have been installed in the world. However, a large-scale blackout occurred in Malaysia in 1996. Combined cycle and gas turbine plants sequentially tripped out. The cause of this chain trip was thought to be a system frequency drop. Considering these backgrounds, it is important to study dynamic behavior of combined cycle plants. Several dynamic models of the combined cycle plant have been proposed. In our analysis, we use some of them and build a model for a single-shaft combined cycle plant. We execute numerical simulations to see how the combined cycle behaves when the system frequency drops.
引用
收藏
页码:1110 / 1115
页数:6
相关论文
共 10 条
[1]
LOAD REPRESENTATION IN POWER SYSTEM STABILITY STUDIES [J].
CONCORDIA, C ;
IHARA, S .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (04) :969-977
[2]
DEMELLO FP, 1994, IEEE T POWER SYST, V9, P1698
[3]
Frankel O H, 1984, GENETICS NEW FRONTIE, V4, P1
[4]
Hanna K D, 1992, Refract Corneal Surg, V8, P152
[5]
Inoue T., 1999, Transactions of the Institute of Electrical Engineers of Japan, Part B, V119-B, P788
[6]
*JAP EL POW INF CT, 1996, KAIG DENR, P103
[7]
Kunitomi K, 2001, P IEEE POW ENG SOC W
[8]
GAS-TURBINE AIR-FLOW CONTROL FOR OPTIMUM HEAT-RECOVERY [J].
ROWEN, WI ;
VANHOUSEN, RL .
JOURNAL OF ENGINEERING FOR POWER-TRANSACTIONS OF THE ASME, 1983, 105 (01) :72-79
[9]
SIMPLIFIED MATHEMATICAL REPRESENTATIONS OF HEAVY-DUTY GAS-TURBINES [J].
ROWEN, WI .
JOURNAL OF ENGINEERING FOR POWER-TRANSACTIONS OF THE ASME, 1983, 105 (04) :865-869
[10]
Suzaki S., 2000, Transactions of the Institute of Electrical Engineers of Japan, Part B, V120-B, P1146