Transient stability of power system integrated with doubly fed induction generator wind farms

被引:55
作者
Chowdhury, Md Ayaz [1 ]
Shen, Weixiang [2 ]
Hosseinzadeh, Nasser [3 ]
Pota, Hemanshu Roy [4 ]
机构
[1] Swinburne Univ Technol, Fac Engn Comp & Sci, Kuching 93350, Sarawak, Malaysia
[2] Swinburne Univ Technol, Fac Sci Engn & Technol, Melbourne, Vic 3122, Australia
[3] Sultan Qaboos Univ, Dept Elect & Comp Engn, Muscat 123, Oman
[4] Univ New S Wales, Sch Engn & Informat Technol, Australian Def Force Acad, Canberra, ACT 2600, Australia
关键词
ENERGY FUNCTION; TURBINE; MODEL;
D O I
10.1049/iet-rpg.2014.0035
中图分类号
X [环境科学、安全科学];
学科分类号
083001 [环境科学];
摘要
A new quantitative assessment of transient stability for power systems integrated with doubly fed induction generator (DFIG) wind farms is proposed by evaluating the transient energy margin (TEM) through the formulation of the transient energy function (TEF) for multimachine systems. To achieve an accurate TEM, the TEF is modified to account for the separation of the critical machines from the system and an unstable equilibrium point is calculated on the basis of post-fault trajectory reaching the potential energy boundary surface. Simulation results show that such power systems integrated with DFIG wind farms are more sensitive to transient events of higher voltage sag, longer fault clearing time, lower load operation and higher wind power penetration level. It is also observed that machines located far from the fault are also exposed to inferior transient stability because of fault with geographical dispersion of wind farms. As a result, advanced switchgear, faster isolators, more efficient power reserve systems and advanced reactive power compensating devices must be equipped to ensure reliable operation of power systems integrated with the DFIG wind farms during transient events.
引用
收藏
页码:184 / 194
页数:11
相关论文
共 17 条
[1]
An aggregate model of a grid-connected, large-scale, offshore wind farm for power stability investigations - importance of windmill mechanical system [J].
Akhmatov, V ;
Knudsen, H .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2002, 24 (09) :709-717
[2]
[Anonymous], 1994, POWER SYSTEM STABILI
[3]
[Anonymous], 2012, Wind power in power systems
[4]
[Anonymous], 2010, PSS E 32 ON LINE DOC
[5]
PRACTICAL METHOD FOR THE DIRECT ANALYSIS OF TRANSIENT STABILITY [J].
ATHAY, T ;
PODMORE, R ;
VIRMANI, S .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1979, 98 (02) :573-584
[6]
A BCU METHOD FOR DIRECT ANALYSIS OF POWER-SYSTEM TRANSIENT STABILITY [J].
CHIANG, HD ;
WU, FF ;
VARAIYA, PP .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1994, 9 (03) :1194-1200
[7]
Comparative study on fault responses of synchronous generators and wind turbine generators using transient stability index based on transient energy function [J].
Chowdhury, M. A. ;
Hosseinzadeh, N. ;
Shen, W. X. ;
Pota, H. R. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2013, 51 :145-152
[8]
Smoothing wind power fluctuations by fuzzy logic pitch angle controller [J].
Chowdhury, M. A. ;
Hosseinzadeh, N. ;
Shen, W. X. .
RENEWABLE ENERGY, 2012, 38 (01) :224-233
[9]
Antigen energy function: a new energy function for transient stability assessment [J].
Dhole, GM ;
Khedkar, MK .
ELECTRIC POWER SYSTEMS RESEARCH, 2005, 74 (02) :315-322
[10]
Transient stability limit conditions analysis using a corrected transient energy function approach [J].
Fang, DZ ;
Chung, TS ;
Zhang, Y ;
Song, WN .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2000, 15 (02) :804-810