Reduction of the net harmonic current produced by single-phase non-linear loads due to attenuation and diversity effects

被引:26
作者
El-Saadany, EF [1 ]
Salama, MMA [1 ]
机构
[1] Univ Waterloo, Dept Elect & Comp Engn, Waterloo, ON N2L 3G1, Canada
关键词
net harmonic current; single-phase non-linear loads; electromagnetic transient program; attenuation distribution systems; diversity;
D O I
10.1016/S0142-0615(98)00007-6
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The increasing use of compact fluorescent lights, as well as single-phase electronic lands, has the potential to increase the overall harmonic distortion levels on distribution systems. The possible impact of the interactions between both load voltage and current harmonics due to the presence of the source impedance is studied. The effects of varying the load power levels and combining different load types an the current harmonic distortion are also analyzed The analysis uses the electromagnetic transient program (EMTP) to model the different loads as well as the whole system. The computer simulations are supported by laboratory testing. The main conclusion of this work is that neglecting the source impedance will result in overestimating the current harmonics produced by non-linear loads. The harmonic levels are reduced due to both attenuation and diversity of harmonic phase angles among different load types. We also conclude that using a combination of different load types can result in a reduction of the current distortion. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:259 / 268
页数:10
相关论文
共 10 条
[1]  
CRNOSIJA P, 1984, IEE PROC-C, V131, P81, DOI 10.1049/ip-c.1984.0011
[2]   EVALUATION OF HARMONIC IMPACTS FROM COMPACT FLUORESCENT LIGHTS ON DISTRIBUTION-SYSTEMS [J].
DWYER, R ;
KHAN, AK ;
MCCLUSKEY, RK ;
SUNG, R ;
MCGRANAGHAN, M ;
TANG, L ;
HOUY, T .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1995, 10 (04) :1772-1780
[3]  
*EL TRANS PROGR EM, 1987, REF MAN RUL BOOK
[4]   VOLTAGE DISTORTION IN DISTRIBUTION FEEDERS WITH NONLINEAR LOADS [J].
EMANUEL, AE ;
JANCZAK, J ;
PILEGGI, DJ ;
GULACHENSKI, EM ;
ROOT, CE ;
BREEN, M ;
GENTILE, TJ .
IEEE TRANSACTIONS ON POWER DELIVERY, 1994, 9 (01) :79-85
[5]  
EMANUEL AE, 1993, IEEE T PWRD, V8, P1451
[6]   A TIME-DOMAIN 3-PHASE POWER-SYSTEM IMPEDANCE MODELING APPROACH FOR HARMONIC FILTER ANALYSIS [J].
GIRGIS, AA ;
QUAINTANCE, WH ;
QIU, J ;
MAKRAM, EB .
IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (02) :504-510
[7]  
Heydt G.T., 1994, ELECT POWER QUALITY
[8]   EFFECT OF SUPPLY VOLTAGE HARMONICS ON THE INPUT CURRENT OF SINGLE-PHASE DIODE BRIDGE RECTIFIER LOADS [J].
MANSOOR, A ;
GRADY, WM ;
THALLAM, RS ;
DOYLE, MT ;
KREIN, SD ;
SAMOTYJ, MJ .
IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (03) :1416-1422
[9]   PREDICTING THE NET HARMONIC CURRENTS PRODUCED BY LARGE NUMBERS OF DISTRIBUTED SINGLE-PHASE COMPUTER LOADS [J].
MANSOOR, A ;
GRADY, WM ;
STAATS, PT ;
THALLAM, RS ;
DOYLE, MT ;
SAMOTYJ, MJ .
IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (04) :2001-2006
[10]   Power factor definitions and power transfer quality in nonsinusoidal situations [J].
Sharon, D .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1996, 45 (03) :728-733