Inter- and intraobserver reliability assessment of the Cobb angle: manual versus digital measurement tools

被引:201
作者
Gstoettner, Michaela [1 ]
Sekyra, Katrin [1 ]
Walochnik, Nadja [1 ]
Winter, Peter [1 ]
Wachter, Roland [1 ]
Bach, Christian M. [1 ]
机构
[1] Innsbruck Med Univ, Dept Orthoped Surg, A-6020 Innsbruck, Austria
关键词
intraobserver reliability; interobserver reliability; scoliosis; Cobb's angle; radiography;
D O I
10.1007/s00586-007-0401-3
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The objective of this study is to determine the intraobserver and interobserver reliability of end vertebra definition and Cobb angle measurement using printed and digital radiographs of 48 patients with scoliosis. The Cobb angle and the end vertebra were assessed by six observers in 48 patients with scoliosis using printed and digital radiographs. Definition of end vertebra and measurement of the Cobb angle was repeated three times with a 3 week interval. Intraclass correlation coefficients (ICC) were used to determine the interobserver and intraobserver reliabilities. 95% prediction limits for the errors in measurements are provided. For the Cobb angle a mean ICC of 0.97 was determined for intra- and interobserver reliability measurement of the printed radiographs. For the electronic radiographs a mean ICC value of 0.93 was determined for interobserver reliability and a mean ICC value of 0.96 for intraobserver reliability. Intraobserver ICC for definition of end vertebrae was 0.8 for both methods. Interobserver ICC was 0.83 for the manual and 0.74 in the digital method. One pitfall in angle measurement implies the Cobb method itself which measures in two dimensions. Until we develop a proper tri-dimensional measuring system an error is introduced. For the Cobb angle measurement the definition of end vertebrae introduces the main source of error. Digital radiography does not improve the measurement accuracy.
引用
收藏
页码:1587 / 1592
页数:6
相关论文
共 13 条
[1]
VARIABILITY OF SCOLIOSIS MEASUREMENT FROM SPINAL ROENTGENOGRAMS [J].
BEEKMAN, CE ;
HALL, V .
PHYSICAL THERAPY, 1979, 59 (06) :764-765
[2]
MEASUREMENT OF SCOLIOSIS AND KYPHOSIS RADIOGRAPHS - INTRAOBSERVER AND INTEROBSERVER VARIATION [J].
CARMAN, DL ;
BROWNE, RH ;
BIRCH, JG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (03) :328-333
[3]
Fleiss J.L., 1986, The Design and Analysis of Clinical Experiments
[4]
Digital radiography of scoliosis with a scanning method: radiation dose optimization [J].
Geijer, H ;
Verdonck, B ;
Beckman, KW ;
Andersson, T ;
Persliden, J .
EUROPEAN RADIOLOGY, 2003, 13 (03) :543-551
[5]
Digital radiography of scoliosis with a scanning method: Initial evaluation [J].
Geijer, H ;
Beckman, KW ;
Jonsson, B ;
Andersson, T ;
Persliden, J .
RADIOLOGY, 2001, 218 (02) :402-410
[6]
GROSS C, 1983, B HOSP JOINT DIS ORT, V43, P171
[7]
THE PREDICTION OF CURVE PROGRESSION IN UNTREATED IDIOPATHIC SCOLIOSIS DURING GROWTH [J].
LONSTEIN, JE ;
CARLSON, JM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (07) :1061-1071
[8]
MEASUREMENT OF THE COBB ANGLE ON RADIOGRAPHS OF PATIENTS WHO HAVE SCOLIOSIS - EVALUATION OF INTRINSIC ERROR [J].
MORRISSY, RT ;
GOLDSMITH, GS ;
HALL, EC ;
KEHL, D ;
COWIE, GH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (03) :320-327
[9]
THE SIGNIFICANCE OF ROENTGENOGRAPHIC MEASUREMENT IN SCOLIOSIS [J].
ODA, M ;
RAUH, S ;
GREGORY, PB ;
SILVERMAN, FN ;
BLECK, EE .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1982, 2 (04) :378-382
[10]
EVALUATION OF RELIABILITY OF RADIOLOGICAL METHODS FOR REGISTRATION OF SCOLIOSIS [J].
SEVASTIKOGLOU, JA ;
BERGQUIST, E .
ACTA ORTHOPAEDICA SCANDINAVICA, 1969, 40 (05) :608-+