Hematologic profile of sepsis in neonates: Neutrophil CD64 as a diagnostic marker

被引:129
作者
Bhandari, Vineet [1 ]
Wang, Chao [2 ]
Rinder, Christine [2 ]
Rinder, Henry [2 ]
机构
[1] Yale Univ, Sch Med, Dept Pediat, Div Perinatal Med, New Haven, CT 06520 USA
[2] Yale Univ, Sch Med, Dept Lab Med, New Haven, CT 06520 USA
关键词
newborn; infection; neutrophils; flow cytometry;
D O I
10.1542/peds.2007-1308
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
OBJECTIVE. The goal was to determine the utility of neutrophil CD64 as a diagnostic marker for sepsis in neonates. METHODS. A prospective study that enrolled consecutive infants with suspected sepsis was performed. Complete blood count with differential, blood culture, and CD64 index measurement were performed, and neutrophil CD64 indices were correlated with the diagnoses of confirmed and suspected sepsis. RESULTS. There were 293 episodes of sepsis evaluations for 163 infants. Infants with sepsis episodes (confirmed or suspected; n = 40) were of greater gestational age (34.7 +/- 0.9 weeks), compared with those (n = 123) with no sepsis (32.6 +/- 0.5 weeks), but had similar birth weights (2325 +/- 200 vs 1969 +/- 94 g) and Apgar scores at 1 and 5 minutes. There was no difference in the duration of hospitalization for the 2 groups. As expected, the hematologic profiles of sepsis episodes (n = 128) were characterized by higher white blood cell counts, absolute neutrophil counts, absolute band counts, and immature/total neutrophil ratios but lower platelet counts. Sepsis episodes had higher neutrophil CD64 indices (5.61 +/- 0.85 vs 2.63 +/- 0.20). For all sepsis episodes, the CD64 index had an area under the curve, in receiver operating characteristic analysis, of 0.74; with a cutoff value of 2.30, the CD64 index in combination with the absolute neutrophil count had the highest negative predictive value (93%) for ruling out sepsis and 95% sensitivity for diagnosing sepsis. For culture-positive sepsis episodes, the CD64 index had the highest area under the curve (0.852) of all hematologic variables, with a sensitivity of 80% and a specificity of 79%, with a cutoff value of 4.02. CONCLUSIONS. Neutrophil CD64 is a highly sensitive marker for neonatal sepsis. Prospective studies incorporating CD64 into a sepsis scoring system are warranted.
引用
收藏
页码:129 / 134
页数:6
相关论文
共 53 条
  • [1] Afroza S, 2006, Mymensingh Med J, V15, P108
  • [2] BECKSAGUE CM, 1994, PEDIATR INFECT DIS J, V13, P1110, DOI 10.1097/00006454-199412000-00008
  • [3] Infection in late preterm infants
    Benjamin, Daniel K., Jr.
    Stoll, Barbara J.
    [J]. CLINICS IN PERINATOLOGY, 2006, 33 (04) : 871 - +
  • [4] Bhandari V, 1992, Indian Pediatr, V29, P571
  • [5] Bhandari V., 2000, CURRENT CONCEPTS PED, P92
  • [6] Nosocomial sepsis in neonates with single lumen vascular catheters
    Bhandari V.
    Eisenfeld L.
    Lerer T.
    Holman M.
    Rowe J.
    [J]. The Indian Journal of Pediatrics, 1997, 64 (4) : 529 - 535
  • [7] Seventy-five years of neonatal sepsis at Yale: 1928-2003
    Bizzarro, MJ
    Raskind, C
    Baltimore, RS
    Gallagher, PG
    [J]. PEDIATRICS, 2005, 116 (03) : 595 - 602
  • [8] BUCK C, 1994, PEDIATRICS, V93, P54
  • [9] Proteomic biomarkers of intra-amniotic inflammation: Relationship with funisitis and early-onset sepsis in the premature neonate
    Buhimschi, Catalin S.
    Buhimschi, Irina A.
    Abdel-Razeq, Sonya
    Rosenberg, Victor A.
    Thung, Stephen F.
    Zhao, Guomao
    Wang, Erica
    Bhandari, Vineet
    [J]. PEDIATRIC RESEARCH, 2007, 61 (03) : 318 - 324
  • [10] Developmental regulation of the immune system
    Clapp, DW
    [J]. SEMINARS IN PERINATOLOGY, 2006, 30 (02) : 69 - 72